REMOTE CONTROL

Preparation before operation

During Operation

Step 1:

Step 2:

Remove the battery cover and insert

new batteries

.

The remote display will alternately

flash

by p

To change the setting, remove the batteries
and press the “ON/OFF” button, then repeat
steps 1 and 2.
Your remote control is now ready for use

If there is no display, or only part display,
remove the batteries and repeat steps 1 and
2 above. If this does not solve the problem
and the batteries have been replaced,
contact your nearest service centre for
advice.

(AAA), making sure the + and -

match the compartment markings (Fig 10)

“COOL” or “HEAT”.

Select the

operating mode to match your cooler type.

ressing the MODE button when the

correct setting is displayed.

If the display disappears, or the remote
control will not operate the air conditioner, the
batteries may need to be replaced.

The Supercool must be plugged in and

switched on for the remote control to operate
the air conditioner. To use, point at the signal

!

!

Select “COOL” for Supercool NR, TRB or FR
Select “HEAT” for Supercool TRC

Note!

Signal

transmission point

Display area

On/Off button

Mode button

Clock button

Fan speed
adjust button

Hold button

Battery
compartment

Battery cover

Swing button

Minute button

Hour button

Timer button

Temperature

increase/decrease

buttons

receiving window on the control panel and
press the remote button. The air conditioner
will “beep” when a signal has been received.
If there is no beep, press the remote button
again, ensuring it is within range (6 metres) of
the air conditioner.

If there are two of the same air conditioners
installed, they cannot be controlled
separately. When you operate either
remote, it will turn on both air conditioners if
they are both within signal range (6 metres).

Don’t let the remote control drop onto hard
surfaces or be subjected to sudden shocks
in any way. The warranty does not cover
misuse or accidental damage.

Don’t place the remote control in direct
sunlight, or near extremes of temperature.
This will affect the control’s temperature
reading.

Don’t allow the remote control to get wet.

Don’t place near strong electromagnetic
waves.

Don’t mix old and new batteries

!

If the

remote control will not be used for a long
time, remove the batteries to avoid
corrosion.

Care of your remote control

!

NOTE:

WASTE BATTERIES SHOULD
BE DISPOSED OF CORRECTLY

9

10

6

Summary of Contents for Supercool

Page 1: ...Instruction Manual Please read these instructions carefully and save this book for future reference Supercool Portable Refrigerated Air Conditioner Supercool NR TRB TRC FR...

Page 2: ......

Page 3: ...ning unit that supplies refrigerated air to a personal area within a room It is not intended to function as a house or room air conditioner Be sure the appliance has been securely and correctly instal...

Page 4: ...rom spilling Electrical Safety Check voltage before connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply Caution Ensure the ap...

Page 5: ...d Exhaust Fitting window end 3 Remote Control Remote Control compartment Air outlet Control panel Air Intake Filter Power cord Condensate drain pipe Drain Air Intake Exhaust Air Outlet 3 4 Handle Wind...

Page 6: ...d The window attachment can be installed horizontally or vertically depending on the window Attach the condensate hose to the air conditioner Then run it out through the rubber grommet in the window a...

Page 7: ...ss to decrease the outlet temperature Temperature set button Swing Control button Press to enable disable air outlet louvres to sweep from side to side To avoid damage to the control panel do not oper...

Page 8: ...ion point Display area On Off button Mode button Clock button Fan speed adjust button Hold button Battery compartment Battery cover Swing button Minute button Hour button Timer button Temperature incr...

Page 9: ...select the desired temperature Press the FAN SPEED button on the control panel or FAN button on the remote control to select fan speed Each press will cycle the fan speed as below High speed Medium s...

Page 10: ...button to adjust the time Each time the button is pressed the time will increase in 1 hour increments OFF When the air conditioner is working only the TIMER OFF can be set When the air conditioner is...

Page 11: ...ain and will now disappear and the buttons will perform their normal functions Self check function Self lock function 9 How to cancel the timer Setting the timer at the cooler To cancel the timer pres...

Page 12: ...ioner clean regularly Cleaning the housing Cleaning the filter Note Never operate the air conditioner without the filter Use a soft damp cloth to wipe the body clean Never use aggressive chemicals spi...

Page 13: ...d All exhaust air needs to be completely removed from the room The air conditioner is not as cool as it once was Is the filter dusty or dirty restricting the airflow Is the air inlet or outlet blocked...

Page 14: ...z Supercool NR Supercool FR Supercool TRB Supercool TRC Personal Cooling Personal Cooling Personal Cooling Personal Heating Cooling 2600 9000Btu hr 3500 12000Btu hr 4100 14000Btu hr 3500 12000Btu hr 3...

Page 15: ...out notice 13 Supercool TRC wiring diagram GN CC compressor capacitor 25uF 450V Supercool NR 30uF 450V Supercool TRB TRC TRX CF fan capacitor 4uF 450V Waste electrical products must not be disposed of...

Page 16: ...e policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specification...