background image

2

General Safety

Transport the air conditioner in an
upright position only, or leave it in an
upright position for at least 2 hours
before use (Fig 1).

Use only in the upright position on a flat
level surface and at least 50cm from any
objects.

Ensure the air conditioner is connected to
a correctly grounded power supply (refer
to the rating label located at the back of the
unit).

Do not place objects on the air conditioner
or restrict air inlets / outlets (Fig 2).

Closely supervise any children and pets
when the air conditioner is in use.

For indoor use only.

Do not store or operate the appliance near
any flammable substances.

During operation, water will collect in the
bottom tank of the air conditioner.

Be

careful when moving the unit to prevent
water from spilling.

Electrical Safety

! Check voltage: before

connecting the electrical power cord to
a power outlet, check that the air
conditioner voltage is the same as your
power supply.

Caution

Ensure the appliance has been installed in
a c c o r d a n c e w i t h n a t i o n a l w i r i n g
regulations.

Plug the air conditioner directly into a
properly installed power outlet. Never use
an extension cord, double adaptor or multi
power outlet board to run this air
conditioner.

Switch off and unplug when not in use.

Do not use in humid environments such as
bathrooms or other steamy or wet areas.

Do not touch or operate the air conditioner
with wet/damp hands or when standing
barefoot.

Do not pull the unit along by the power cord
or place the power cord near a source of
heat.

Always unroll the power cord

completely before use.

If the power cord is damaged, in order to
avoid a hazard, it must be replaced by an
electrician, or similarly qualified person or
service agent.

1

2

SAFETY

Summary of Contents for Supercool

Page 1: ...Instruction Manual Please read these instructions carefully and save this book for future reference Supercool Portable Refrigerated Air Conditioner Supercool NR TRB TRC FR...

Page 2: ......

Page 3: ...ning unit that supplies refrigerated air to a personal area within a room It is not intended to function as a house or room air conditioner Be sure the appliance has been securely and correctly instal...

Page 4: ...rom spilling Electrical Safety Check voltage before connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply Caution Ensure the ap...

Page 5: ...d Exhaust Fitting window end 3 Remote Control Remote Control compartment Air outlet Control panel Air Intake Filter Power cord Condensate drain pipe Drain Air Intake Exhaust Air Outlet 3 4 Handle Wind...

Page 6: ...d The window attachment can be installed horizontally or vertically depending on the window Attach the condensate hose to the air conditioner Then run it out through the rubber grommet in the window a...

Page 7: ...ss to decrease the outlet temperature Temperature set button Swing Control button Press to enable disable air outlet louvres to sweep from side to side To avoid damage to the control panel do not oper...

Page 8: ...ion point Display area On Off button Mode button Clock button Fan speed adjust button Hold button Battery compartment Battery cover Swing button Minute button Hour button Timer button Temperature incr...

Page 9: ...select the desired temperature Press the FAN SPEED button on the control panel or FAN button on the remote control to select fan speed Each press will cycle the fan speed as below High speed Medium s...

Page 10: ...button to adjust the time Each time the button is pressed the time will increase in 1 hour increments OFF When the air conditioner is working only the TIMER OFF can be set When the air conditioner is...

Page 11: ...ain and will now disappear and the buttons will perform their normal functions Self check function Self lock function 9 How to cancel the timer Setting the timer at the cooler To cancel the timer pres...

Page 12: ...ioner clean regularly Cleaning the housing Cleaning the filter Note Never operate the air conditioner without the filter Use a soft damp cloth to wipe the body clean Never use aggressive chemicals spi...

Page 13: ...d All exhaust air needs to be completely removed from the room The air conditioner is not as cool as it once was Is the filter dusty or dirty restricting the airflow Is the air inlet or outlet blocked...

Page 14: ...z Supercool NR Supercool FR Supercool TRB Supercool TRC Personal Cooling Personal Cooling Personal Cooling Personal Heating Cooling 2600 9000Btu hr 3500 12000Btu hr 4100 14000Btu hr 3500 12000Btu hr 3...

Page 15: ...out notice 13 Supercool TRC wiring diagram GN CC compressor capacitor 25uF 450V Supercool NR 30uF 450V Supercool TRB TRC TRX CF fan capacitor 4uF 450V Waste electrical products must not be disposed of...

Page 16: ...e policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specification...