background image

LEK

Installation

instruction

C 460

www.contura.eu

Installation instruction 

1

Installationsanleitung 20

Monteringsvejledning 40

Installasjonsanvisning 60

Asennusohje 80

GB

FI

DE

DK

NO

Summary of Contents for C 460

Page 1: ...LEK Installation instruction C 460 www contura eu Installation instruction 1 Installationsanleitung 20 Monteringsvejledning 40 Installasjonsanvisning 60 Asennusohje 80 GB FI DE DK NO ...

Page 2: ...ERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 50 mm to rear 330 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 12 NOx 25 mg m3 OGC 84 mg m3 PM 67 mg m3 Surface temperatures Approved Cleaning options Approv...

Page 3: ... is both environmen tally friendly and efficient for the best heat production Read through these installation instructions carefully befo re installation Read how to best light your stove in the lighting instructions WARNING The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Also take heed of the strong heat radiated throu...

Page 4: ...nstallation work make sure that you check which regulations apply Structural support Check to make sure that the floor is strong enough to support the weight of the stove and chimney If you intend to locate the stove on standard wooden floor joists contact a professional builder to make sure that the construction will withstand the load If the total weight of the stove and the chimney together doe...

Page 5: ... Centre mark for chimney Combustible wall 445 890 520 740 Air inlet Ø64 1025 700 305 410 450 1590 370 930 626 Air inlet Ø64 445 890 Ø280 OBS Min 20 mm Min 2200 mm 1135 1575 470 Air inlet Ø64 1020 700 305 385 190 450 2380 370 930 2715 1135 2655 Air inlet Ø64 Installation distances to walls and ceiling 1040 190 925 Floor plate accessory Centre mark for chimney 1200 min 900 330 250 775 50 240 Combust...

Page 6: ...ortant To prevent condensation in air ducts which pass through heated areas the duct must be insulated with 30 mm of mineral wool covered with aluminium tape It is important to seal carefully around the duct where it passes through the wall or floor Use joint ing compound For ducts longer than 1 0 metre the diameter must be increased to 100 mm and the size of the air vent increased correspondingly...

Page 7: ... fire box and place the steel profiles and metal plates on one side Unsecure the stove on the delivery pallet and fit the extension legs using the hexagon screw s By fitting these legs before removing the stove from the pallet you can avoid scratches to the floor Raise the fire box to a height of 87 mm and tighten the lock nut LEK Unscrew the metal brackets from the rear edge of the side windows L...

Page 8: ...ft the door upwards until it disengages from the lower hinge Ease the bottom of the door slightly sideways until it clears the hinge pin Lower the door to disengage it completely Fitting the smoke ba e Raise the folded front edge of the smoke baffle up over the side pegs Then lift the rear edge of the baffle up over the vermiculite holder LEK Stödtapp sida Vermiculitehållare LEK Side peg Vermiculi...

Page 9: ...e appropriate height To make this easier there is a die cut slot 100 mm from the end see illustration Place the two remaining profiles between the outer ones Cut the minerit boards to the desired width Position the minerit boards edge to edge with a bead of acrylic sealant in the gap and screw them into place with the supplied screws Do not install the upper board until the rear section of the hea...

Page 10: ...GB 8 Fitting the rear panel Secure the vent screen to the rear panel LEK Vent screen Rear panel Screw the rear panel to the supporting profiles of the stove body ...

Page 11: ...er the markings LEK Fit the fan optional accessory in accordance with the Installation Instructions for Fan 2000 C460 Follow the instructions on page 7 when making a hole through the ceiling Slide the flue base over the collar Make sure that the seal round the collar is not dislodged If further sealing material is required heat resistant sealant may be used LEK Top flue connection to steel chimney...

Page 12: ...d the connecting flue with sealing rope Slide the connecting flue over the collar Make sure that the seal round the collar is not dislodged If further sealing material is required heat resistant sealant may be used LEK LEK Täcklock LEK Brytlock For rear flues cut away the punched metal covers on the rear panel and the heat reflector The stove has been prepared for top flue connection before delive...

Page 13: ...sections have been assembled and any surplus cement has been pressed out LEK Kåpa övre Kåpa nedre Hylla Sidstolpe Sockel Passbit sockel Kåpa mitt Täckplatta Övre marmorhylla Nedre marmorhylla Passbit asklåda The supplied silicone is used to secure the marble shelves and to attach the concrete sections to the rear wall When sealing the joint to the rear wall only the paint over acrylic sealant must...

Page 14: ...se in place or squeeze out a few small blobs of acrylic sealant to keep it from moving Note however that it must be possible to remove the filler piece when cleaning the stove or servicing the fan If a fan is to be connected make holes for the cables either in the wall or in the back of the plinth Draw the cables through the hole before securing the plinth to the base plate LEK LEK Drill as marked...

Page 15: ...ntirely LEK LEK The gap between the rebate in the concrete components and the rear panel must be carefully sealed with silicone This is necessary to prevent the wrong kind of convection currents in the warm air Squeeze out a liberal amount of silicone all along the edge of the rear panel Any surplus pressed out when the concrete sections are fitted can be smoothed by hand if you first dip your fin...

Page 16: ...ver Insulate the sealing plate with the blocks of insulating material supplied For the low model only one of the insulation blocks is required LEK LEK In this instance it is extra important to make sure that there is a tight seal between the concrete surround and the rear panel as hot air will be collected in this cavity If you are installing the low 460 model you can now fit the marble top to the...

Page 17: ...n LEK Lay the first insulating block on top of the sealing plate Make sure that the insulation forms a tight seal around the flue base the start section of the flue and the concrete surround Then fit the second insulating block in place This has a larger hole in the middle and should form a tight seal with the outside of the chimney module Fit the bottom chimney module into place Startrör Avtätnin...

Page 18: ...ther with any height extension pieces that may be necessary Leave a gap of at least 20 mm between the top of the chimney surround and the ceiling LE K Fill the two expansion gaps in the hood with acrylic sealant LEK Fix the marble slabs to the mantelshelf with silicone ...

Page 19: ...the adhesive to fill the gaps between the different sections of the chimney hood adding pieces of fibre glass tape to reinforce the seal The adhesive should also be used to fill the gap between the hood and the marble slabs of the shelf The gap between the concrete surround and the marble shelf is filled with acrylic sealant LEK The grilles are simply placed loose over the air vents Before fitting...

Page 20: ...ire 4 Push the door to but do not close it until the fire is burning well after about 10 15 minutes 5 When the first pile of logs has burnt down stoke up the fire again by placing 3 or 4 logs weighing 2 2 5 kg in all on the embers Pulling out the damper bar opens the grate disc This should only be done for a short time when lighting or re stoking the fire to ensure that the wood catches light quic...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ... AB Box 134 285 23 Markaryd Sweden www contura se Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu ...

Reviews: