background image

5+1+1 day Programmable Thermostat

 For electric baseboard & convection heaters

Instruction Manual

model: M6001A

High VOLTAGE

120 V/240 V AC, 60 Hz

BY/PAR 

CANARM

Summary of Contents for M6001A

Page 1: ...5 1 1 day Programmable Thermostat For electric baseboard convection heaters Instruction Manual model M6001A High VOLTAGE 120 V 240 V AC 60 Hz BY PAR CANARM ...

Page 2: ...ntary Information Setting of High Limit Function Clock Settings About Programs Default Programs and Customize Programs Customizing the Programs Reset Programs All Settings Temporary Override and Hold Function Current Temperature Display Power Bar and Heat ON Icon Usage Monitor Memory Backup and Thermostat Surface Temperature Specifications Troubleshooting Warranty 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Page 3: ...or Sunday with up to 4 temperature settings per day morning day evening night Set and display temperature in Celsius or Fahrenheit in half degrees High limit function set a maximum temperature to help manage heating costs TRIAC system operates on 20 second or 240 second cycles for accurate temperature reading and provides quiet operation Maintain room temperature accurately to within 0 3 C 0 6 F U...

Page 4: ...tat Do not expose this thermostat to dripping or splashing Do not expose this thermostat to excess heat Do not attempt to disassemble repair or modify this thermostat Prior to Use THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE IT IS STRONGLY RECOMMENDED TO HAVE A CERTIFIED ELECTRICIAN ON SITE TO ENSURE THE SAFE INSTALLATION OF YOUR THERMOSTAT IN QUEBEC THIS PRODUCT ...

Page 5: ...ace system 24 V Wall mounted furnace Multi stage system Single stage heat pump Electric radiant floor heater Heat pump Electric baseboard heater 120 V 240 V Fan assisted convection heaters Electric radiant ceiling heater Not compatible with some hot water heating systems NOT COMPATIBLE WITH CENTRAL HEATING FURNACES LOW VOLTAGE CIRCUITS DO NOT WIRE TO A SYSTEM EXCEEDING 12 5 A 3000 W 240 V OR 1500 ...

Page 6: ... at these temperatures but should be kept away from fire hazards For NEW home installation choose the location of the metal electrical box carefully It SHOULD BE MOUNTED Approximately 5 1 5 m from the floor Near or in a frequently used room preferably on an inside partitioning wall On a section of wall without pipes or duct work It SHOULD NOT BE MOUNTED Near temperature radiating objects that may ...

Page 7: ...mproper wiring or any resulting damages Improper installation by a non professional automatically voids the warranty Before installation begins Verify that the heating appliance being connected to is within the specified load range Ensure that the thermostat being replaced is also rated for 120 V or 240 V Ensure that the heating system is protected by appropriate circuit breakers or fuses connecte...

Page 8: ...res in the wall box Refer to the diagram CAUTION ENSURE NO BARE WIRE IS EXPOSED Note If there are four wires connected to the old thermostat the two extra wires should be connected together with a wire nut not supplied 5 Mount the thermostat on the wall box using the two supplied screws through the mounting holes then replace the faceplate Place screws in the two right or two left holes 6 Reconnec...

Page 9: ...on has been enabled the lock symbol will begin flashing for five minutes See page 14 for further details on the Setting of High Limit Function Reset All Settings If the above method does not work you may have to reset all thermostat settings Note This is a total reset which clears all settings of custom programs clock time and option settings The unit will be restored to factory default settings T...

Page 10: ...ons and Display CURRENT TEMPERATURE POWER OUTPUT LEVEL OVERRIDE ON ICON HOLD FUNCTION WEEKDAYS TEMPERATURE SCALE CELSIUS OR FAHRENHEIT HEAT ON ICON PROGRAM PERIODS TIME USAGE LOCK SYMBOL P M DISPLAY FOR 12 HR CLOCK MODE ...

Page 11: ...ons or to set the clock and the day of the week HOLD To override temperature programs PROG To enter program mode and scroll settings To manually adjust the temperature or to make selections in program mode or option mode RESET Resets program clock to factory defaults Buttons and Display RESET Remove the faceplate to locate the Reset button ...

Page 12: ...k format 12 Hr will flash 2 Press or to toggle between 12 hour or 24 hour format 3 Press SET to proceed to OPTION 2 or wait for 15 seconds to confirm and exit Option Settings Note 12 hour clock format is the default mode OPTION 2 Heat Cycle Rate 1 Press SET again to advance to the second option Cr 1 will flash 2 Press or to adjust setting See cycle rate supplementary information on page 12 Cr 0 Fu...

Page 13: ...Press or to toggle between ºC or ºF temperature scales 3 Press SET or wait for 15 seconds to confirm and exit Option Settings Note A change of the temperature display mode will result in the reset of all programs i e All programs set by user will be deleted Heat Cycle Rate supplementary information Cycle rate determines the heating on off time cycles and the level of proportional power required to...

Page 14: ...tandard electric heating devices without fans and will provide the most energy efficient heating and a stable temperature Cr 2 is a 240 second cycle rate This means the heating will turn on and off once every 240 seconds This is the recommended setting for fan assisted heaters and radiant floor ceiling heating devices Pre comfort Recovery supplementary information This thermostat is equipped with ...

Page 15: ...me for three seconds to activate high limit function at the set temperature The LOCK symbol will appear to confirm that the high limit feature is on To DISABLE the high limit setting feature 1 Press the RESET button Remove the faceplate to locate the reset button Press with a blunt object Clock will be reset and the lock symbol will begin flashing for five minutes 2 Press the USAGE and SET buttons...

Page 16: ...etting mode SET icon will appear 2 Press or button to scroll to the correct time of day Hold the button to accelerate 3 Press SET again to enter weekday settings Weekday symbols will flash 4 Press or button to set day of the week Press SET or wait 15 seconds for normal display to return 5 Press SET or wait 15 seconds to complete clock setting and exit Setup Set Clock Time flashes Set Weekday Weekd...

Page 17: ...amming P1 MORNING P2 DAY P3 EVENING P4 NIGHT This is typically the morning period when you may prefer to wake up at a warmer temperature This is usually an energy saving period for the time when you are away from home The temperature setting can be reduced to minimize energy consumption If you are not away from home on a particular day you may override this setting by manually adjusting the temper...

Page 18: ... temperature settings PERIOD PROG TIME HEAT SET POINT Morning P1 7 00 a m 20 5ºC 69 0ºF Day P2 8 00 a m 20 5ºC 69 0ºF Evening P3 5 00 p m 20 5ºC 69 0ºF Night P4 11 00 p m 17 5ºC 63 5ºF 1 Default Pre programmed time and temperature settings PERIOD PROG TIME HEAT SET POINT Morning P1 6 00 a m 20 5ºC 69 0ºF Day P2 8 00 a m 17 5ºC 63 5ºF Evening P3 5 00 p m 21 0ºC 70 0ºF Night P4 10 00 p m 17 0ºC 62 5...

Page 19: ...its will flash 3 Press USAGE TIME to switch to start time mode Start time will flash 4 Press or to set start time for P1 Time will flash Note USAGE TIME will toggle between temperature and start time modes 5 Press PROG to adjust the next program periods P2 P3 P4 Repeat the above steps until all four programs are adjusted to your needs 6 Press PROG to enter Saturday programming periods P1 will appe...

Page 20: ...ms Note This action will restore custom programs to the factory default programs only but will not affect the clock time or option settings Reset All Settings to delete all settings 1 Remove the thermostat faceplate to reveal the RESET button Page 7 2 Press HOLD and RESET buttons at the same time to clear all settings Note This is a total reset which clears settings for custom programs clock time ...

Page 21: ... next scheduled program period Hold Function This function maintains a constant temperature and disables temperature program periods 1 Press the HOLD button once to enter the Hold mode HOLD symbol will appear When Hold mode is activated you may manually adjust the temperature by pressing or However all programs will be disabled If no temperature changes are manually selected the current temperatur...

Page 22: ... the temperature setting The Power Bar indicates the current output power level 1 bar 10 power 10 bar 100 power When the heating system is activated at partial power a proportional number of bars will appear e g 60 6 bars When the heating system is activated at maximum power all 10 bars will be displayed Heat ON Icon The flashing fire symbol will be displayed when the heating system is on Operatio...

Page 23: ...AGE TODAY Press the USAGE button again to view USAGE THIS WEEK total time from Monday to today Press the USAGE button again to view 7 DAY USAGE total time from last six days plus today USAGE TODAY starts at midnight USAGE THIS WEEK automatically resets itself on Monday morning after midnight on Sunday A new week begins Monday morning Operation ...

Page 24: ...ermostat Surface Temperature In normal operation the surface temperature of the thermostat may range from 45 55ºC 113 31ºF This is perfectly normal as this thermostat is rated to operate safely at these temperatures However it is recommended that the thermostat not be installed near heat sensitive flammable material such as exposed wood wallpaper or other fire hazards Specifications Number of Prog...

Page 25: ...cuit breaker is open Check heating device to see if it is disabled Check the wiring installation with a certified electrician The heating system is running constantly Check if the temperature is set too high Check the wiring installation with a certified electrician The temperature display is incorrect Ensure thermostat is not installed near a draft in direct sunlight or near heat generating devic...

Page 26: ... dated proof of purchase to the retailer from which you purchased it NOT COMPATIBLE WITH ANY 120 240 VOLT CIRCUIT CONTROL by par Canarm Customer Service number English 1 800 265 1833 Numéro du Service à la Clientèle de Canarm Français 1 800 567 2513 Made in China Imported by Importé par CONTROL by Canarm CANARM Ltd ltée 2157 Parkedale Avenue Brockville Ontario K6V 5V6 www canarm com 2012 Kelan Hud...

Reviews: