5.6.1 Display messages
Status indications
The following tables indicate the various possible mnemonics which can
be displayed by the drive and their meaning.
Trip types are not listed here but can be found in Chapter
12
if required.
Alarm indications
5.7 Changing the operating mode
Changing the operating mode returns all parameters to their default
value, including the motor parameters.
Procedure
Use the following procedure only if a different operating mode is
required:
1. Enter either of the following values in Pr
0.00
, as appropriate:
1253 (Europe, 50Hz AC supply frequency)
1254 (USA, 60Hz AC supply frequency)
2. Change the setting of Pr
0.48
as follows:
The figures in the second column apply when serial communications are
used.
3. Press
or momentarily close the RESET contact.
The new setting takes effect and all the parameters revert to the
appropriate default values for the new mode.
5.8 Saving parameters
Procedure
Enter 1000 in Pr
xx.00
Press the red reset button or toggle the reset digital input
(ensure Pr
xx.00
returns to 0)
5.9 Defaulting the drive
Procedure
Enter 1233 (EUR 50 Hz settings) or 1244 (USA 60 Hz settings) in
Pr
xx.00
Press the red reset button or toggle the reset digital input (ensure
Pr
xx.00
returns to 0)
Lower
display
Conditions
Drive output
stage
Act
Regeneration mode active
Enabled
Regen mode> The Regen drive is enabled and
synchronised to the supply.
ACUU
AC Supply loss
Enabled
The drive has detected that the AC supply has been
lost and is attempting to maintain the
DC
bus voltage
by decelerating the motor.
dc
DC applied to the motor
Enabled
The drive is applying
DC
injection braking.
dEC
Decelerating
Enabled
The drive is decelerating the motor.
inh
Inhibit
Disabled
The drive is inhibited and cannot be run.
Drive enable
signal not applied to terminal 30 or Pr
6.15
is set to 0.
POS
Positioning
Enabled
The drive is positioning/orientating the motor shaft.
rdY
Ready
Disabled
The drive is ready to be run.
run
Running
Enabled
The drive is running.
SCAn
Scanning
Enabled
OL> The drive is searching for the motor frequency
when synchronising to a spinning motor.
Regen> The drive is enabled and is synchronising to
the line.
StoP
Stop or holding zero speed
Enabled
The drive is holding the motor at zero speed.
Regen> The drive is enabled but the AC voltage is too
low, or DC Bus voltage still rising or falling.
triP
Trip condition
Disabled
The drive has tripped and is no longer controlling the
motor. The trip code appears on the upper display.
Lower
display
Conditions
Air
Control PCB ambient temperature near maximum limit
The ambient temperature around the control PCB has reached 90
°
C
(194
°
F) and the drive will trip OA if the temperature continues to rise
(see the
OA
trip).
br.rS
Braking resistor overload
The braking-resistor [I x t] accumulator in the drive has reached 75%
of the value at which the drive will be tripped.
hot
Heatsink temperature near maximum limit
The drive heatsink has reached 90
°
C (194
°
F) and the drive will trip
Oh2 if the temperature continues to rise (see the
Oh2
trip).
OVLd
Motor overload
The motor [I x t] accumulator in the drive has reached 75% of the value
at which the drive will be tripped.
Pr 0.48 setting
Operating mode
0
Open-loop
1
Closed-loop Vector
2
Closed-loop Servo
3
For operation in this mode, refer to
the
Unidrive Regen Installation
Guide