Reference selection
Frequency/speed ref. 1
Frequency/speed ref. 2
Keypad
reference
Precision reference
(not used with Menu 0)
Preset references
(use Macro 3)
JOG
SELECT
RUN
FORWARD
RUN
REVERSE RESET
Menu 0 changes from default configuration
6
0.35
0.05
Reference
selector
ANALOG INPUT 1/
INPUT 2 SELECT
Minimum
frequency/
speed clamp
Maximum
frequency/speed
clamp
0.01
0.02
OL> EXTERNAL TRIP
CL> DRIVE ENABLE
6
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
9.4 Macro logic diagrams and Menu 0 parameter changes
Figure 9-1 Macro 1 Easy mode logic diagram