76
SM-Universal Encoder Plus User Guide
www.controltechniques.com
Issue Number: 6
9.3
Parameter descriptions
The menu for the relevant slot appears for the new Solutions Module category with the
default parameter values for the new category. When no Solutions Module is fitted in the
relevant slot this parameter is zero. When a Solutions Module is fitted this parameter
displays the identification code as shown below.
The new parameters values are not stored in EEPROM until the user performs a
parameter save. When parameters are saved by the user in the drive EEPROM the
option code of the currently fitted Solutions Module is saved in EEPROM. If the drive is
subsequently powered-up with a different Solutions Module fitted, or no Solutions
Module fitted where one was previously fitted, the drive gives a Slot.dF or SLot.nf trip.
x.01
Option ID code
RO
Uni
PT
US
Ú
0 to 599
Ö
Update rate: Write on power-up
Code
Solutions Module
Category
Dumb
module
0
No Solutions Module fitted
101
SM-Resolver
Feedback
9
102
SM-Universal Encoder Plus
104
SM-Encoder Plus
9
201
SM-I/O Plus
Automation
9
203
SM-I/O Timer
204
SM-PELV
206
SM-I/O 120V
207
SM-I/O Lite
301
SM-Applications
302
SM-Application Lite
303
SM-EZMotion
403
SM-Profibus DP
Fieldbus
404
SM-Interbus
406
SM-CAN
407
SM-DeviceNet
408
SM-CANopen
409
SM-SERCOS
410
SM-Ethernet
501
SM-SLM
SLM
x.02
Option software version
RO
Uni
NC
PT
Ú
00.00 to 99.99
Ö
Update rate: Write on power-up
When operating with an Issue 3 SM-Universal Encoder Plus, the software must be of
version
03.xx.xx
. When operating with an Issue 4 SM-Universal Encoder Plus, the
software must be of version
04.xx.xx
.
Failure to comply with the above can result in Solutions Module failure.
NOTE