SM-Universal Encoder Plus User Guide
107
Issue Number: 6
www.controltechniques.com
11.4
Encoder inputs PL1
Ab, Fd, Fr, Ab.SErvo, Fd.SErvo, Fr.SErvo, SC, SC.HiPEr, SC.EndAt, SC.SSI and
SC.SErvo encoders
11.5
Encoder outputs PL1
Simulated Ab, Fd encoder output (software simulation and hardware)
1
+24V freeze
8
RS485 freeze
9
RS485\ freeze
Type
EIA 485 differential receivers
Maximum frequency
600kHz
Line loading
<2 unit loads (for terminals 1 to 4)
32 unit loads (for terminals 5 and 6)
1 unit load (for terminals 7 to 12)
Line termination components
120
Ω
Working common mode range
+12V to –7V
Absolute maximum applied voltage relative to
0V
±
25V
Absolute maximum applied differential voltage
±
25V
The freeze input function is not available with EndAt only and SSI only encoders
NOTE
3
Channel A frequency F
4
Channel A\ frequency F\
5
Channel B direction D
6
Channel B\ direction D\
8
Marker pulse Z
9
Marker pulse Z\
Type
EIA 485 differential receivers
Maximum frequency
500kHz
Line loading
<2 unit loads (for terminals 1 to 4)
32 unit loads (for terminals 5 and 6)
1 unit load (for terminals 7 to 12)
Line termination components
120
Ω
Working common mode range
+12V to –7V
Absolute maximum applied voltage relative to
0V
±
25V
Absolute maximum applied differential voltage
±
25V