GETTING TO KNOW YOUR 
CONTOUR P12 PUMP

EARTH TERMINAL

PUMP TERMINALS

By swapping the wires around the pump will 
change direction. Use the ‘Test’ button 
(in the Control Box) to set the 
direction to match the inflow and outflow.
Once the inlet and outlet direction has been 
established this 

should not

 be changed.

The pump speed can also be adjusted (in the 
Control Box) to match the shower flow rate.

WALL PLATE

Quick release wall bracket allows for easy 
installation.
The pump housing clips onto the wall plate 
for easy fitting.

INLET & OUTLET CONNECTORS

Elongated inlet & outlet connectors ensure an 
airtight fit.
Ensure all pipework is tightened securely to 
avoid any air being sucked in whilst the pump 
is operating. 
Once the inlet and outlet direction has been 
established this 

should not

 be changed.

Technical Helpline: 0845 402 9924

Pump Housing 
Dimensions

A = 190mm
B = 210mm
C = 330mm

The housing clips onto the wall plate. 
Manufactured from ABS.

The fl ow switch & control box covers 
are optional accessories, 
see above.

Pump Only 
Dimensions

(Housing not fi tted) 

A = 180mm
B = 205mm
C = 270mm

B

C

A

ENSURE

 

YOU USE   

22mm Flexible 

Pipe supplied.

 

FOR SHOWER TRAYS - Kit A

• UPSW3 is only 30mm in depth
• 22mm outlet
• Chrome top fl ange

STANDARD KIT REF: 05PP01A 
LINK PUMP ONLY: 05PP01A-L

FOR FLOOR FORMERS - Kit B

• Use with an Eagle Two shower tray or Prinia shower tray 
• UPSW-4 is only 32mm in depth
• 22mm outlet
• Chrome top fl ange

STANDARD KIT REF: 05PP01D 
LINK PUMP ONLY: 05PP01D-L

FOR SHOWER TRAYS - Kit D

• USG1-WH is only 45mm in depth
• 22mm outlet
• Manufactured in white ABS
• Withstands wheelchair loadings  

  

STANDARD KIT REF: 05PP01B 
LINK PUMP ONLY: 05PP01B-L

FOR TOP ACCESS SHOWER TRAYS - PUMP ONLY

Pump only should be used with a Gannet top access 
shower tray.

 

STANDARD KIT REF: 05PP01 
LINK PUMP ONLY: 05PP01-L

ADDITIONAL ITEMS

Additional fl owswitch for 
use with a mixer shower.

 

Ref: 05PP11

Optional Control Box  

Ref: 05PP16

Optional Flow Switch cover 

Ref: 05PP17

•  

STANDARD

 kits include 1 x flowswitch and are meant for typical 

    electric shower installations. 
•  

LINK

 kits have no flowswitch and are meant to be wired directly to  

     a suitable link enabled electric shower.

Summary of Contents for P12

Page 1: ...ED BY ALL POLE DISCONNECTION A QUALIFIED ELECTRICIAN MUST MAKE THE MAINS ELECTRICAL CONNECTION THE PUMP MUST NOT BE FITTED IN THE SHOWERING AREA INSTALLATION GUIDELINES READ BEFORE BEGINNING YOUR INSTALLATION TO ENSURE YOU MAINTAIN P12 AT PEAK PERFORMANCE ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE If you are installing an electric shower single flowswitch see sections A B D If you are instal...

Page 2: ...imensions Housing not fitted A 180mm B 205mm C 270mm B C A ENSURE YOU USE 22mm Flexible Pipe supplied FOR SHOWER TRAYS Kit A UPSW3 is only 30mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01A LINK PUMP ONLY 05PP01A L FOR FLOOR FORMERS Kit B Use with an Eagle Two shower tray or Prinia shower tray UPSW 4 is only 32mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01D LIN...

Page 3: ...nector can be used ENSURE ALL PIPEWORK IS SECURELY FIXED TO THE WALL WITH SUITABLE PIPE CLIPS Do not leave excess pipe colied up beneath the shower tray Fit the pump within 2 metres of the gully or waste To achieve optimum pump performance of 12 litres per minute we recommend the pump be installed no higher than 350mm from the top of the shower waste outlet to the underside of the wall plate as sh...

Page 4: ...ter in the water supply going to the shower This must be fitted before the flowswitch The arrow on the filter must point in the direction the water is flowing Install the flowswitch control in the cold water supply going to the shower IMPORTANT FIT AS CLOSE AS POSSIBLE TO THE SHOWER TO STOP ANY FALSE READINGS OCCURRING Fit in any position or orientation the arrow on the flow switch must point in t...

Page 5: ...ur fuse connect the cable to the connections in the control box as follows BROWN to L BLUE to N See WIRING DIAGRAM ABOVE BY PRESSING HOLDING THE TEST BUTTON THE PUMP WILL RUN THE PUMP WILL STOP WHEN THE BUTTON IS RELEASED THERE IS AN EARTH TERMINAL ON THE PUMP SEE POINT 18 Connect the cable from the motor output to the pump and run the rest of the cable to the control box Attach the 2 wires with t...

Page 6: ...ed in any way The warranty does not include Damage or blockages caused by foreign objects to the pump or flowswitch The cost arising from the removal or reinstatement of tiling etc Damage resulting from the product failing General wear and tear To report a fault contact our Technical Helpline on 0845 402 9924 TECHNICAL SPECIFICATION Self priming 24 volt pump 22mm inlet outlet Outlet from the pump ...

Page 7: ...aintain the pump at it s peak performance ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE Assess your installation prior to installing to ensure the pump control box and flow switch are situated in an accessible area CONTOUR P12 Shower Waste Pump the P12 instructions supplied before beginning your installation to ensure you Technical Helpline 0845 402 9924 ...

Reviews: