Continental Refrigerator RBT240 Operation Manual Download Page 8

The RBT240 and RBT270 are braking test benches for
light vehicles.

3.1

Presentation of the different

elements

The electric control box communicates with the
braking test bench and sends the information to the
control trolley PC.

3.1.1

Control Trolley

The mobile cabinet

houses,

A large 23" coloured

screen with directional
mount for clear
visibility.

Windows 10 PC

Mouse & keyboard

with protective cover

A4 printer

The image can be
echoed to a remote
screen via the HDMI
port.

Optional:

Vehicle Exhaust Gas Analyser (VEGA)

Diesel Smoke Meter (DSM)

3.1.2

Electric Control Box

This unit houses:

the processing

card

The connection

terminals for the
sensors and
actuators

the control part

(contactors)

There is a location
for an emergency
stop.

3.1.3

RBT240 and MK240: Braking Bench

RBT240 Class 4 ATL

MK240 Motorcycle Adapter

3

Overview

Width of the braking area

800mm - 2,200mm

Height

275mm

Max. force

750 daN

Operating Manual RBT240 / RBT270

Operating Manual RBT240 / RBT270

14

15

2.14

Warranty terms and conditions

The warranty is voided by any alteration of the equipment
or use other than that defined by the manufacturer and
made without the manufacturer's permission, and by any
deterioration of specifications resulting from incorrect
servicing or the absence of precautions.

Any use of hardware and/or software not been approved by
Continental constitutes a modification of our products, and
hence exclusion of all liability and warranty claims, even if
the hardware has been subsequently removed, or the
software erased in the interim. Our products must not be
modified in any way. Furthermore, our products may only
be used with original accessories. Disregard for the above
will render all warranty claims invalid.

The present Continental tester may only be used with
operating systems approved by Continental. Using the
Continental tester with different operating systems to those
which we have approved will render our warranty obligation
null and void, in accordance with our terms of delivery. In
addition, we cannot assume liability for damages and
consequential damages which are the result of the use of a
non-approved operating system.

Full terms and conditions are available on request.

Continental cannot be held liable for incorrect
measurements resulting from the use of an operating mode
different from the one recommended in this manual, or if
the operating, servicing and safety conditions are not
followed.

2.15

Working environment conditions

The equipment environment must meet the following
specifications:

The equipment must be used under shelter.

Temperature:
field of reference

20ºC 5.

Surrounding
temperature
(max. Range)

B0ºC and +40ºC

Operating
conditions

Relatively humidity between 5% and 85%

Water

Negligible (no vertical dripping of drops of water).
No traces of damp on the wall of the premises
and correct ventilation

Dust

The dust must not have any electrical impact
Presence of solid bodies greater than 2.5mm

Corrosive
substances

Possible presence of corrosive or polluting agents
from atmospheric pollution, but no direct contact

Impacts

Impacts less than 2 joules

Vibrations

Usual in an industrial environment. Frequency
between 10 and 50Hz. Amplitude less than
0.15mm

Electromagnetic
and electronic
influences or
radiation

No power switchgear, high frequency current
emitters, devices containing radioactive
substances, high voltage power lines, electricity
transport lines close by.

Sunlight

It should be reduced to a minimum

Grounding

Grounding must be carried out according to the
type of soil and in compliance with applicable
regulations.

Summary of Contents for RBT240

Page 1: ...I324455 Issue 1 ATL Roller Brake Tester Class 4 Class 7 Operations Manual RBT240 RBT270 ...

Page 2: ...ecked on the brake tester 13 2 11 Servicing maintenance verification or repair work 13 2 12 Recycling 13 2 13 Fire prevention 13 2 14 Warranty terms and conditions 14 2 15 Working environment conditions 14 3 Overview 15 3 1 Presentation of the different elements 15 3 2 Technical Specifications 17 3 3 Installation Commissioning 17 4 Control 18 4 1 Selecting the vehicle and configuring the test 18 4...

Page 3: ...ators must wear work clothes without loose straps and loops This includes work shoes without laces Loose straps and laces may catch in the rollers Operating Manual RBT240 RBT270 Operating Manual RBT240 RBT270 4 5 1 About This Manual and endanger the operator 2 2 Information Before commissioning it is essential to Correctly understand what is described in this manual and to be aware of the capaciti...

Page 4: ...of Conformity Continental Automotive Trading Uk Ltd Sales Enquiries 44 0 121 725 1400 36 Gravelly industrial Park Email sales cryptontechnology com B24 8TA Web www cryptontechnology com This declaration of conformity is issued under the sole responsibility of the manufacturer Manufacturer Details of Equipment Description Conformity The object of the declaration is in conformity with the relevant U...

Page 5: ...ger Continental Automotive Trading UK Ltd I324444Iss 1 Operating Manual RBT240 RBT270 Operating Manual RBT240 RBT270 8 9 2 4 Certificates of Acceptance 2 4 1 RBT240 Class 4 Roller Brake Tester CERTIFICATE OF ACCEPTANCE ROLLER BRAKE TESTER RBT Brand CONTINENTAL Model RBT240 Equipment Identification Number EINCBR20612A112093 Software Version above V2 00 Suitable to testing ATL Class 4 Suitable to te...

Page 6: ...Product Manager Continental Automotive Trading UK Ltd I324446 Iss 1 Operating Manual RBT240 RBT270 Operating Manual RBT240 RBT270 10 11 2 4 3 MK240 Class 4 Motorcycle Adapter CERTIFICATE OF ACCEPTANCE ROLLER BRAKE TESTER RBT Brand CONTINENTAL Model MK 240 Adaptor plate for RBT240 for class 1 2 Equipment Identification Number EIN BR2063 112095MC Software Version above n a Suitable to testing ATL No...

Page 7: ...and installed by trained qualified engineers The chassis is fitted with lifting rings and are delivered on pallets Their installation over an inspection pit must be carried out using a sling with chains attached to the 4 lifting rings screwed onto each chassis Once installed over an inspection pit they are completely embedded and cannot be moved 2 6 Instructions for the electric installation Remar...

Page 8: ... warranty claims invalid The present Continental tester may only be used with operating systems approved by Continental Using the Continental tester with different operating systems to those which we have approved will render our warranty obligation null and void in accordance with our terms of delivery In addition we cannot assume liability for damages and consequential damages which are the resu...

Page 9: ... when using with a PC and touch screen using IR technology In this case the touch function will be disrupted and will not work properly In this case it is recommended to pivot the screen slightly away from the sunlight Operating Manual RBT240 RBT270 Operating Manual RBT240 RBT270 16 17 3 1 4 RBT270 and MK270 Braking Bench RBT270 Class 4 5L 7 ATL MK270 Motorcycle Adaptor 3 1 5 Remote Control The re...

Page 10: ...rol 4 1 Selecting the vehicle and configuring the test The following information is required for all vehicle classes Class I II Number of wheel Motorbike brake type brake system Front Rear Linked Registration number Make Model Registration date Class III 4x4 Selection Note See the car manufacturer s prescriptions before Single wheel axle Axle1 front or Axle2 Rear Parking brake type Axle1 front Axl...

Page 11: ... have any time you can press OK Class III Class IV or Class VII example Operating Manual RBT240 RBT270 Operating Manual RBT240 RBT270 20 21 Software Command To Do Drive into brake tester on the right or on the left The weight measurement starts automatically The weighing results are displayed on the screen Select options Left Right wheel Exit if you don t have any brake only weight And Press OK Ap...

Page 12: ...g Manual RBT240 RBT270 Operating Manual RBT240 RBT270 22 23 4 3 2 Automatic Mode ATL Refer to the MOT Insection Manual for details of the correct MOT test procedure Software Command To Do Drive into brake tester The weight measurement starts automatically The weighing results are displayed on the screen Motors starts automatically 2 secs to centralise Stay inside the car Nobody around the car duri...

Page 13: ...he completed test report 5 4 Centralisation In order to connect to AWS the equipment will require an X 509 client certificate which is issued by DVSA These certificates are being supplied to the Authorised Examiner Designated Manager in a zip file format and are unique for each client Unzip this file with Authorised Examiner Designated Manager ID as password The minimum list files form DVSA requir...

Page 14: ...e of waste can have negative effects on the environment and public health because these electric and electronic products generally contain potentially dangerous substances In parallel your complete collaboration in the correct disposal of this product will contribute to a better use of natural resources For more information on equipment collection points for recycling contact your town hall the wa...

Page 15: ...5 1366 Email support cryptontechnology com Continental Automotive Trading UK Ltd 36 Gravelly Industrial Park Birmingham B24 8TA United Kingdom www cryptontechnolgy com E O E The Company reserves the right to introduce improvements in design or specification without prior notice The sale of this product is subject to our standard terms conditions and relevant product warranty ...

Page 16: ...e The sale of this product is subject to our standard terms conditions and relevant product warranty Print identification number I322990 Issue 4 November 2020 Continental Automotive Trading UK Ltd 36 Gravelly Industrial Park Birmingham B24 8TA United Kingdom Phone 0121 725 1366 uksupport continental corporation com www continental aftermarket com ...

Reviews: