C-7.5. Rosan
®
Studs Installation
Any type of Rosan
®
stud (size-on-size type or step type) may be installed using the
appropriate wrench. Install the stud to the dimensions specified in Figure C-10.
CAUTION: Location of the flange is important in preventing the
lock ring drive tool from making contact with surface “A” in Figure
C-10. Any impact or pressure on surface A may damage the threads
in the cylinder head resulting in a loose fit.
Figure C-10.
Rosan® stud installation dimensions