Starter Replacement
10-3.1. Starter Removal
Procedure
WARNING
Turn the ignition switch OFF and disconnect engine electrical
power before commencing maintenance. Do not stand or place
equipment within the arc of the propeller.
1.
Disconnect engine electrical power; verify the Ignition Switch is turned OFF.
2.
Disconnect the aircraft battery and electrical cable from the starter motor in
accordance with the airframe manufacturer’s instructions.
3.
Remove the bolt (Figure 10-3) (7), lock washer (4), and washers (6) from the rear of
the accessory case and the rear engine lifting eye. Discard the lock washers.
4.
Remove three sets of nuts (5), lock washer (4), washers (3) and spacers (8) from the
starter mounting flange. Carefully remove the starter motor assembly without
damaging the mounting stud threads. Discard the lock washers.
5.
Remove and discard the gasket (1).
NOTE: The IOF-240 starter is not field serviceable. Operational
defects may only be corrected by replacement.
6.
Replace a defective starter with a serviceable starter.
Lifting Eye
Lifting Eye
Figure 10-3.
IOF-240 Starter
1 Gasket
5 Nut
2 Starter
Motor
6 Washers
3 Seal
washer
7 Bolt
4 Lock
Washer
8 Spacer