O-200-D & X Series Engine Installation and Operation Manual
4-21
3 January 2017
Engine Operation
4-5.2.2. Ground Operation in Hot Weather
1. Monitor oil and cylinder temperatures closely during taxiing and engine run up.
2. Operate with cowl flaps full open
3. Do not operate the engine at high RPM except for necessary operational checks.
4. If take-off is not to be made immediately following engine run-up, face the aircraft
into the wind with the engine idling at 900-1000 RPM.
4-5.2.3. Take-off and Initial Climb Out in Hot Weather
1. Mixture control ................................................ FULL RICH
NOTE: Under extreme conditions, it may be necessary to manually lean
the mixture to sustain engine operation at low RPM.
2. Do not operate the engine at maximum power longer than necessary to establish the
climb configuration recommended by the aircraft manufacturer.
3. Monitor temperatures closely.
4. Maintain sufficient airspeed and attitude to provide engine cooling.
5. Cowl flaps ........................................................ FULLY OPEN (if equipped)
Summary of Contents for O-200-D
Page 111: ......
Page 112: ...www continentalmotors aero...