28
W415-1540 / D / 03.23.17
EN
* See venting section.
IMPORTANT: THE FIRESTOP ASSEMBLY PROVIDED MUST BE USED WHEN THE VENT PIPES PASS
THROUGH ANY COMBUSTIBLE WALL, FLOOR OR CEILING.
NOTE:
THE MINIMUM ENCLOSURE VOLUME MUST BE INCREASED BY NO LESS THAN THE VOLUME OF
THE RECESS. THIS ADJUSTMENT CAN BE MADE BY INCREASING ANY OR ALL OF THE HEIGHT, WIDTH,
AND DEPTH OF THE ENCLOSURE.
5.2.1 ALCOVE CLEARANCE TO COMBUSTIBLES ENCLOSURE
34 7/8"
[88.6cm]
1" [25mm]
FIRESTOP
ASSEMBLY
NON-COMBUSTIBLE
MATERIAL
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE
MYLAR
SLEEVE
COMBUSTIBLE
STEEL STUD
FRAME
3"
[76mm]
2"
[51mm]
49 3/4"
[126.4cm]
MINIMUM
PLUS RISE *
MAX.
4 1/2"
[114mm]
7 1/2"
[191mm]
42 3/8"
[107.6cm]
59 1/2"
[151.1cm]
CEILING
78"
[198cm]
ENCLOSURE
HEIGHT
FIRESTOP
ASSEMBLY
NON-COMBUSTIBLE
MATERIAL
STEEL STUD
FRAME
NON-COMBUSTIBLE
BRICK
COMBUSTIBLE
34 7/8"
[88.6cm]
1" [25mm]
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE
49 3/4"
[126.4cm]
MINIMUM
PLUS RISE *
59 1/2"
[151.1cm]
CEILING
78"
[198cm]
ENCLOSURE
HEIGHT
MYLAR
SLEEVE
3"
[76mm]
2"
[51mm]
NON-COMBUSTIBLE
BRICK
COMBUSTIBLE
6 3/4"
[883mm]
Summary of Contents for CX70NTE