27
W415-1540 / D / 03.23.17
EN
5.2 MINIMUM ENCLOSURE CLEARANCES
34 7/8"
[88.6cm]
1" [25mm]
FIRESTOP
ASSEMBLY
NON-COMBUSTIBLE
MATERIAL
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE
MYLAR
SLEEVE
COMBUSTIBLE
STEEL STUD
FRAME
3"
[76mm]
2"
[51mm]
49 3/4"
[126.4cm]
MINIMUM
PLUS RISE *
MAX.
4 1/2"
[114mm]
7 1/2"
[191mm]
42 3/8"
[107.6cm]
59 1/2"
[151.1cm]
CEILING
78"
[198cm]
ENCLOSURE
HEIGHT
FIRESTOP
ASSEMBLY
NON-COMBUSTIBLE
MATERIAL
STEEL STUD
FRAME
NON-COMBUSTIBLE
BRICK
COMBUSTIBLE
34 7/8"
[88.6cm]
1" [25mm]
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE
49 3/4"
[126.4cm]
MINIMUM
PLUS RISE *
59 1/2"
[151.1cm]
CEILING
78"
[198cm]
ENCLOSURE
HEIGHT
MYLAR
SLEEVE
3"
[76mm]
2"
[51mm]
NON-COMBUSTIBLE
BRICK
COMBUSTIBLE
6 3/4"
[883mm]
TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 59 1/2" (151.1cm). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
* See "MINIMUM FRAMING DIMENSION" section for details on reducing vent pipe top clearances.
These parameters also apply to the illustrations found in the "MINIMUM ENCLOSURE
CLEARANCES" section.