11
W415-1540 / D / 03.23.17
EN
3.2 TYPICAL VENT INSTALLATION
TOP VENT
34 5/8"
(88cm)
THE FIRST TWO FEET
OF OUTER 8” (203mm)
DIAMETER VENT PIPE FROM
THE APPLIANCE MUST BE
WRAPPED IN THE 1” (25mm)
THICK INSULATION SLEEVE
(SUPPLIED).
WARNING!
15 1/8" (38.4cm)
MINIMUM
34 5/8"
(88cm)
18" (45.7cm)
MAXIMUM
* See "VENTING" section
49 3/4"
(126.4cm)
MINIMUM
PLUS RISE*
Use the periscope kit to locate the air termination above grade. The periscope
must be installed so that when fi nal grading is completed, the bottom air slot is
located a minimum 12” (305m) above grade. The maximum allowable vent length
(including both rise and run) is 10’ (3m).
9.3B
REV B : ADDED METRIC DIMENTIONS
12" (30.5cm)
MIN. TO
GRADE
30" (76.2cm)
MINIMUM
40 FT (12m)
MAXIMUM
3 FT (0.9m)
MINIMUM
16" (40.6cm)
MINIMUM
3.3 SPECIAL VENT INSTALLATIONS
3.3.1 PERISCOPE TERMINATION
THE FIRST TWO FEET
OF OUTER 8” (203mm)
DIAMETER VENT PIPE FROM
THE APPLIANCE MUST BE
WRAPPED IN THE 1” (25mm)
THICK INSULATION SLEEVE
(SUPPLIED).
WARNING!
34 5/8"
(88cm)