Continental Disc Corporation SANITRX HPX Installation Instructions Manual Download Page 1

GEP-6070 

Rev. U  102335 

Ref. I.D.:  15574 

 

 
 
 
 
 
 
 
WARNING

 

 
 

USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING RUPTURE DISC.  

THESE INSTRUCTIONS DO NOT PURPORT TO ADDRESS ALL OF THE SAFETY FACTORS ASSOCIATED WITH THE RUPTURE 
DISC’S USE IN SERVICE.  IT IS THE RESPONSIBILITY OF THE USER TO ESTABLISH APPROPRIATE SAFETY, HEALTH, AND 
TRAINING MEASURES FOR THEIR PERSONNEL INSTALLING, SERVICING, OR WORKING IN AN AREA WHERE RUPTURE DISC 
ASSEMBLIES ARE IN USE.  SERVICE AND/OR MAINTENANCE ON OR AROUND THE RUPTURE DISC DEVICE MUST NOT BE 
PERFORMED WHILE THE DEVICE IS SUBJECTED TO OPERATING PRESSURES AND/OR TEMPERATURES. 

IT IS THE USER’S SOLE RESPONSIBILITY FOR DESIGN AND PLACEMENT OF RUPTURE DISCS WITHIN THEIR FACILITY AND 

UPON THE EQUIPMENT UPON WHICH THE RUPTUR

E DISC OF USER’S SELECTION IS TO BE LOCATED.  IT IS USER’S SOLE 

RESPONSIBILITY FOR THE DESIGN OF ADEQUATE VENTING AND INSTALLATION OF ADEQUATE VENT PIPING OR 
DIRECTIONAL FLOW AFTER RUPTURE OCCURS WITH THE RUPTURE DISC AS INTENDED.  WHEN SIZE IS SPECIFIED, 
CONTINENTAL DISC CORPORATION ASSUMES THAT ADEQUATE PROVISIONS HAVE BEEN MADE BY PURCHASER FOR 
PROPER VENTING OF A SYSTEM TO RELIEVE THE SPECIFIC PRESSURE.  LOCATE RUPTURE DISC WHERE PEOPLE OR 
PROPERTY WILL NOT BE EXPOSED TO THE SYSTEM DISCHARGE IN CASE OF RUPTURE.  VENT TOXIC OR FLAMMABLE 
FUMES OR LIQUIDS TO A SAFE LOCATION TO PREVENT PERSONAL INJURY OR PROPERTY DAMAGE. 

IT IS THE USER’S SOLE RESPONSIBILITY TO SPECIFY THE BURST PRESSURE RATING OF A RUPTURE DISC AT A 

COINCIDENT TEMPERATURE AT WHICH THE RUPTURE DISC IS TO BE USED.  A RUPTURE DISC IS A TEMPERATURE 
SENSITIVE DEVICE.  THE BURST PRESSURE OF THE RUPTURE DISC IS DIRECTLY AFFECTED BY ITS EXPOSURE TO THE 
COINCIDENT TEMPERATURE.  GENERALLY, AS THE TEMPERATURE AT THE RUPTURE DISC INCREASES, THE BURST 
PRESSURE DECREASES; INVERSELY, AS THE TEMPERATURE AT THE RUPTURE DISC DECREASES, THE BURST PRESSURE 
MAY INCREASE.  FAILURE TO PROPERLY UTILIZE A RUPTURE DISC AT THE SPECIFIED COINCIDENT TEMPERATURE 
COULD CAUSE PREMATURE FAILURE OR OVERPRESSURIZATION OF A SYSTEM. 

THE INSTANTANEOUS RELEASE OF PRESSURE FROM THE RUPTURE DISC CAN CREATE VIOLENT NOISES DUE TO THE 

DISCHARGE AT SONIC VELOCITY.  IT IS THE 

USER’S SOLE RESPONSIBILITY TO PROTECT AGAINST HEARING DAMAGE TO 

ANY BYSTANDERS. 

RUPTURE DISCS AND TAGS ARE MADE OF METAL FOILS OF VARYING THICKNESS.  THE METAL EDGES MAY BE SHARP.  

PERSONNEL INSTALLING OR EXAMINING THE RUPTURE DISCS SHOULD PROTECT AGAINST CUTS OR INJURY WHEN 
HANDLING THE RUPTURE DISC.  DO NOT LIFT A RUPTURE DISC BY ITS ATTACHED TAG. 

PARTICLES MAY BE DISCHARGED WHEN THE RUPTURE DISC RUPTURES.  THESE PARTICLES MAY BE PART OF THE 

RUPTURE DISC ITSELF, OR OTHER ENVIRONMENTAL MATTER IN THE SYSTEM.  IT IS THE USE

R’S SOLE RESPONSIBILITY 

TO ASSURE THAT THESE PARTICLES ARE DIRECTED TO A SAFE AREA TO PREVENT PERSONAL INJURY OR PROPERTY 
DAMAGE. 

THERE IS NO GUARANTEE OF RUPTURE DISC LIFE.  SUCH LIFE SPAN IS AFFECTED BY CORROSION, CREEP AND 

FATIGUE, AND PHYSICAL DAMAGE.  THESE CONDITIONS WILL DERATE THE RUPTURE DISC TO A LOWER SET PRESSURE.  
THE CUSTOMER AND/OR USER SHOULD BE PREPARED TO HANDLE PREMATURE FAILURE OF THE RUPTURE DISC.  THE 
MEDIA OR OTHER ENVIRONMENTAL CONDITIONS SHOULD NOT ALLOW ANY BUILDUP OR SOLIDIFICATION OF MEDIA TO 
OCCUR ON A RUPTURE DISC.  THIS MAY INCREASE THE PRESSURE SETTING OF THE RUPTURE DISC. 

CUSTOMER AND/OR ITS INSTALLER SHALL BE SOLELY RESPONSIBLE FOR THE PROPER INSTA

LLATION OF SELLER’S 

HOLDERS AND RUPTURE DISCS INTO A SYSTEM.  CUSTOMER AND/OR ITS INSTALLER SHALL BE SOLELY RESPONSIBLE 
FOR IMPROPER INSTALLATION AND PHYSICAL DAMAGE RESULTING THEREFROM, INCLUDING BUT NOT LIMITED TO, 
DAMAGE RESULTING FROM LEAKAGE, IMPROPER TORQUING OR SEATING OF A RUPTURE DISC OR FAILURE TO FOLLOW 
INSTALLATION INSTRUCTIONS WHERE PROVIDED. 

RUPTURE DISCS ARE PRECISION SAFETY DEVICES AND MUST BE INSTALLED PROPERLY.  RUPTURE DISCS MUST BE 

INSTALLED BY TRAINED, KNOWLEDGEABLE INSTALLERS AND ONLY WITHIN ENVIRONMENTS SUITABLE AND 
APPROPRIATE FOR A RUPTURE DISC.  CARE MUST BE USED IN A FACILITY'S DESIGN TO PROTECT BOTH THE RUPTURE 
DISC FROM INADVERTENT DAMAGE WHICH COULD CAUSE ITS PREMATURE RELEASE AND TO PROTECT INDIVIDUALS 
EXPOSED TO HAZARDS CREATED BY SUCH SUDDEN RELEASE. 

PROPER INSTALLATION OF A RUPTURE DISC IS CRITICAL TO PERFORMANCE AND TO SAFETY.  FAILURE TO PROVIDE 

PROPER SEATING OF A RUPTURE DISC MAY AFFECT RUPTURE DISC PERFORMANCE, BURST PRESSURE ACCURACY AND 
MAY RESULT IN ITS PREMATURE FAILURE.

 

 

Preparation and Installation of the SANITRX HPX

®

SANITRX HPX

®

 II, or SANITRX

®

 LPX Rupture Disc 

Summary of Contents for SANITRX HPX

Page 1: ...ARGE AT SONIC VELOCITY IT IS THE USER S SOLE RESPONSIBILITY TO PROTECT AGAINST HEARING DAMAGE TO ANY BYSTANDERS RUPTURE DISCS AND TAGS ARE MADE OF METAL FOILS OF VARYING THICKNESS THE METAL EDGES MAY BE SHARP PERSONNEL INSTALLING OR EXAMINING THE RUPTURE DISCS SHOULD PROTECT AGAINST CUTS OR INJURY WHEN HANDLING THE RUPTURE DISC DO NOT LIFT A RUPTURE DISC BY ITS ATTACHED TAG PARTICLES MAY BE DISCHA...

Page 2: ...WHEN INSTALLING A NEW RUPTURE DISC ASSURE THAT THE FLOW DIRECTIONAL ARROWS ON THE RUPTURE DISC THREE DIMENSIONAL TAG POINT IN THE VENT DIRECTION OF THE RELIEF SYSTEM 1 If the Burst Disc Indicator B D I Alarm System is used disconnect the alarm strip from the monitor by unplugging the B D I connector from the lead wire connector 2 Clean the rupture disc sealing areas of both the sanitary fitting in...

Page 3: ...d nuts to finger tightness Torque nuts number 1 and 2 see Figure D with a calibrated torque wrench at 50 increments to a final torque of 20 Ft Lbs 27 N m Based on gasket material type and rupture disc material thickness the torque compression may close the gap between the clamp halves If it does not maintain an equal and parallel gap between the clamp halves throughout the torque sequence Torque n...

Page 4: ... lead wire into the standoff clip 5 Torque each nut with a calibrated torque wrench in a cross torquing pattern to the recommended torque value shown below The gaps between the locking ring halves and the welding flange must be equal during torquing SIZE TORQUE 1 30 In Lbs 3 4 N m 1 1 2 30 In Lbs 3 4 N m 2 42 In Lbs 4 8 N m 3 46 In Lbs 5 2 N m 6 Plug the B D I connector into the lead wire connecto...

Page 5: ...amb 40 C Ta 204 C EC Type Examination Certificate ITS13ATEX27734X THE MAXIMUM INTRINSICALLY SAFE INPUT PARAMETERS ARE AS FOLLOWS Ui 24V dc Ii 50 mA Pi 0 3W THE EQUIVALENT PARAMETERS ARE Ci 0 Li 0 SPECIAL CONDITIONS FOR SAFE USE 1 Temperature Class of the BDI sensor is marked as Tx since the surface temperature is controlled by the process temperature being monitored The sensor itself exhibits negl...