Please note that the fog machines are calibrated for water.

 With thicker, foaming or oily agents 

the medium flow rate changes. The set is calibrated on each other at the factory. Therefore, the indi-
vidual components 

cannot

 be replaced by identical units.

Note:

The fogging time should always be selected according to the quantity to be fogged. Follow the stan-
dard values table in section 3.2.

3.3 

Compressed air supply

Cross sections for compressed air lines

Note:

When using cold fogging technology, please note that compressed air generators should under no 
circumstances suck air from rooms into which agents are fogged.
To protect the compressed air generator, it is essential that it is installed in a frost-free room (not fog-
ged) and protected from moisture. Fog sucked in by the compressor will very quickly contaminate the 
filters. Normally the filter must then be disposed of as hazardous waste. There is also the risk that the 
compressor will suffer mechanical and optical damage in the form of corrosion if it is exposed to fog.
The above recommendations serve to ensure the long-term reliable operation of your air compressor 
and contribute to maintaining the value of the unit.

In order to ensure the required pressure on the unit, 
the compressed air hose plays an important role in 
addition to the compressor performance.
The longer the hose, the larger the hose diameter 
should be used in order to keep the pressure losses 
resulting from the hose length as low as possible.

Nozzle

Hose length

up to 20 m

up to 50 m

W03

8 mm

10 mm

Summary of Contents for CONB22000430

Page 1: ...Technical documentation suitable for CONB22000430 CONTI Motor vehicle fogging device for cold fogging of vehicle interiors with adjustable nozzle angle...

Page 2: ...st be observed To avoid damage to functional components mal functions and water damage comply with operat ing pressures in accordance with specified technical data Disconnect the water supply before a...

Page 3: ...chlorine bleach The mixing of cleaning agents is generally not permitted Use of abrasive cleaning agents and equipment such as unsuitable scouring agents and pad sponges may cause damage Preferably cl...

Page 4: ...OUR ELIMINATION IS THOROUGH CLEANING 4 2 STEPS FOR COMMISSIONING 5 CLEANING AND MAINTENANCE 6 TROUBLESHOOTING FOR FAULTS 7 WARRANTY CONDITIONS We reserve the right to make changes in line with technic...

Page 5: ...vice If you have any problems please contact CONTI Sanit rarmaturen GmbH we will be happy to help you with advice and support 2 Conditions of use 2 1 Intended use of the device The cold fogger can be...

Page 6: ...s that of the appliance it must be able to supply at least 10 A of current All parts of the structure technical equipment stored goods and other items in the room to be treated must be checked for the...

Page 7: ...aterial Without adequate personal protective equipment nebulised substances penetrate the organism faster through inhalation via the lungs than in other forms Neglect of personal protective measures g...

Page 8: ...lso be used However these are often not suitable for continuous operation For this reason it is absolutely neces sary to coordinate with the fog machine manufacturer Breaks must be observed if necessa...

Page 9: ...ors should under no circumstances suck air from rooms into which agents are fogged To protect the compressed air generator it is essential that it is installed in a frost free room not fog ged and pro...

Page 10: ...nen Stark kontaminierte Fl chen sind vor der Applikation direkt zu behandeln Vor der Applikation sind Ledersitze durch eine geeignete Folie abzudecken Nach der Anwendung sollten die Fahrzeugscheiben v...

Page 11: ...belzeit bleibt das Fahrzeug f r ca 30 Minuten verschlossen Bild 8 Nebelrichtung der D se am Nebelge r t einstellen optimale Nebelrichtung nach hinten ber die Kopfst tzen Sitze schr g stellen keine Obe...

Page 12: ...n ist der Kaufbeleg Sch den die durch unsachge m e Behandlung entstehen unterliegen nicht der Gew hrleistung Bei Fragen bitten wir um An gabe der Daten die Sie dem Typenschild entnehmen k nnen Entspre...

Page 13: ...006 42 EC Annex II A and the amending directive 2009 125 EC we declare that the product Cold Fogger complies with these relevant regulations The following harmonized standards were applied EN 12100 1...

Page 14: ...a e 98 35435 Wettenberg Deutschland Tel 49 641 98221 0 Fax 49 641 98221 50 info conti plus www conti plus Druckfehler und Irrt mer sowie technische und ma liche nderungen vorbehalten Errors and techni...

Page 15: ...a e 98 35435 Wettenberg Deutschland Tel 49 641 98221 0 Fax 49 641 98221 50 info conti plus www conti plus Druckfehler und Irrt mer sowie technische und ma liche nderungen vorbehalten Errors and techni...

Page 16: ...uable contribution to their projects Every last detail is contem plated when developing tailor made products resulting in smart individual solutions to suit a plethora of applications and equipment Th...

Reviews: