Important

Be sure to read the attached safety instruc-
tions before installing and commissioning the 
 system  /product. 
Incorrect installation can cause malfunc tions 
and damage and become a danger for the 
user and specialist craftsmen.
The manufacturer does not assume any war-
ranty for improper operation and im proper use.

Electrical wiring and installations must be carried 
out by a qualifi ed electrician in accordance with DIN 
VDE 105-100.
Only insert cables at specifi ed positions. Assump-
tion of warranty only if the specifi ed cable types are 
used.
Observe DIN VDE 100-701 when installing central 
control units.
•  Coin-operated machines must be installed 

in a splash-proof vestibule

•  Control cabinets must be installed in a dry room
At water temperatures above 45 °C there is a risk 
of scalding!
The worksheet DVGW W 551 must be observed!
To avoid damage to functional components, mal-
functions and water damage, comply with operat-
ing  pressures in accordance with specifi ed technical 
data.
Disconnect the water supply before assembly and 
disassembly of water-bearing components and 
 fi ttings.
Before and after installation, fl ush pipes in accord-
ance with DIN EN 806-4 or ZVSHK leafl et “Flushing, 
dis infecting and commissioning of drinking water 
installa tions”.

Store product in a frost-free, dry environment.
Check the fi xing material in the scope of delivery for 
usability for current wall condition.
Only use stainless steel fi xing screws.
Observe maintenance and repair obligations in 
 accordance with VDI/DVGW 6023 or DIN EN 806-5.
Observe DIN 1988-200 or VDI/DVGW 6023 when 
tempo rarily shutting down valves or other water- 
bearing components.
Do not insert or swallow small parts such as screws, 
seals or other metal or plastic parts into the body! 
This can lead to health  damage, even life-threaten-
ing  situa tions!
Before cleaning components, always read the in-
structions for use of the cleaning agent! Consult a 
qualifi ed specialist before using the cleaner.
Water-carrying sections of components must always 
be operated with water only! Oil or other liquids are 
not suitable for operation and can lead to damage 
and malfunction of the component.
The use of spare parts from other manufacturers 
can cause damage to the component and requires 
immediate cancellation of the warranty.

Do not dispose of batteries in house-
hold waste. Obligation to return to 
 municipal collec tion points or trade.

CONTI Sanitärarmaturen GmbH | Hauptstraße 98 | 35435 Wettenberg | Deutschland | Tel. +49 641 98221 0 | Fax: +49 641 98221 50 | [email protected]
www.conti.plus | Druckfehler und Irrtümer sowie technische und maßliche Änderungen vorbehalten. | Errors and technical changes remain reserved.

4

Cleaning information

Surfaces

The most common coating of a sanitary fi tting is the 

chrome-nickel surface fi nish which should be cleaned 

in accordance with DIN EN 248. This would also 

 apply to materials such as stainless steel and plastic 

as well as surfaces which could include  powder and 

wet paint, anodised aluminium and galvanised steel.
Coloured, non-metallic surfaces are generally 

more sensitive than metallic surfaces, especially to 

scratches. It is therefore absolutely necessary to de-

termine the type of surface to be cleaned before 

starting the cleaning process.

General information on cleaning and care of 

 sanitary fi ttings and accessories 

In order to meet the market needs in terms of de-

sign and functionality, modern sanitary products 

today consist of very different materials and thus 

place different demands on the cleaning agents 

used and their ingredients. 

Cleaning agents and tools

Acids are indispensable as a component of cleaning 

agents for the removal of lime deposits.
For sanitary products, however, it is important to 

note that: 
•  Only use cleaning agents intended for the area 

of application.

•  Do not use cleaners containing hydrochloric 

acid, formic acid or acetic acid, as they can 

cause considerable damage even after a single 

application.

•  Only use cleaning agents containing phosphoric 

acid in exceptional cases.

•  Do not use detergents containing chlorine 

bleach.

•  The mixing of cleaning agents is generally not 

permitted.

•  Use of abrasive cleaning agents and equipment, 

such as unsuitable scouring agents and pad 

sponges, may cause damage. 

•  Preferably cleaning textiles are used which bind 

as few particles as possible. (Knitted towels are 

more suitable than woven.)

Tip

Residues of body care products can also cause dam-

age and must be rinsed off immediately after using 

the fi ttings and accessories with clear, cold water 

without leaving any residue. Ongoing damage to 

surfaces that have already been damaged will pro-

gress as a result of the action of cleaning agents. 

Recommendations for cleaning and care 

The instructions for use issued by the cleaning 
agent manufacturers must be strictly followed. 
Generally, it should be noted that:
•  Cleaning must be carried out as required.
•  The detergent dosage and duration of action 

must be adapted to the object-specifi c require-
ments and the detergent must never be allowed 
to work  longer than necessary. 

•  The build-up of calcifi cation must be prevent-

ed by regular cleaning. Water droplets should 
therefore be wiped off with a soft cloth or 
chamois leather after use.

•  Any limescale deposits must be removed by di-

rect application of detergent if necessary.

•  In the case of spray cleaning, do not spray the 

 cleaning solution on the sanitary fi ttings and 
acces sories, but on the cleaning textile (cloth/
sponge) and thus the cleaning is to be carried 
out, as the spray mist can penetrate into open-
ings and cracks etc. of the fi tting and accesso-
ries and cause damage.

•  Wash cleaning textiles as often and thoroughly 

as possible so that only clean cleaning textiles 
with out foreign particles are used. Particles de-
posited in cleaning textiles can lead to scratches 
and damage to surfaces.

•  After cleaning, rinse thoroughly with clear wa-

ter to remove any remaining product buildup.

Surface protection

Lacquered and galvanized surfaces should be pro-
tected with a thin protective fi lm on a regular basis. 
The use of a preservative specially formulated for 
lacquered or galvanised surfaces is recommended.

Cleaning information

Summary of Contents for CONB22000430

Page 1: ...Technical documentation suitable for CONB22000430 CONTI Motor vehicle fogging device for cold fogging of vehicle interiors with adjustable nozzle angle...

Page 2: ...st be observed To avoid damage to functional components mal functions and water damage comply with operat ing pressures in accordance with specified technical data Disconnect the water supply before a...

Page 3: ...chlorine bleach The mixing of cleaning agents is generally not permitted Use of abrasive cleaning agents and equipment such as unsuitable scouring agents and pad sponges may cause damage Preferably cl...

Page 4: ...OUR ELIMINATION IS THOROUGH CLEANING 4 2 STEPS FOR COMMISSIONING 5 CLEANING AND MAINTENANCE 6 TROUBLESHOOTING FOR FAULTS 7 WARRANTY CONDITIONS We reserve the right to make changes in line with technic...

Page 5: ...vice If you have any problems please contact CONTI Sanit rarmaturen GmbH we will be happy to help you with advice and support 2 Conditions of use 2 1 Intended use of the device The cold fogger can be...

Page 6: ...s that of the appliance it must be able to supply at least 10 A of current All parts of the structure technical equipment stored goods and other items in the room to be treated must be checked for the...

Page 7: ...aterial Without adequate personal protective equipment nebulised substances penetrate the organism faster through inhalation via the lungs than in other forms Neglect of personal protective measures g...

Page 8: ...lso be used However these are often not suitable for continuous operation For this reason it is absolutely neces sary to coordinate with the fog machine manufacturer Breaks must be observed if necessa...

Page 9: ...ors should under no circumstances suck air from rooms into which agents are fogged To protect the compressed air generator it is essential that it is installed in a frost free room not fog ged and pro...

Page 10: ...nen Stark kontaminierte Fl chen sind vor der Applikation direkt zu behandeln Vor der Applikation sind Ledersitze durch eine geeignete Folie abzudecken Nach der Anwendung sollten die Fahrzeugscheiben v...

Page 11: ...belzeit bleibt das Fahrzeug f r ca 30 Minuten verschlossen Bild 8 Nebelrichtung der D se am Nebelge r t einstellen optimale Nebelrichtung nach hinten ber die Kopfst tzen Sitze schr g stellen keine Obe...

Page 12: ...n ist der Kaufbeleg Sch den die durch unsachge m e Behandlung entstehen unterliegen nicht der Gew hrleistung Bei Fragen bitten wir um An gabe der Daten die Sie dem Typenschild entnehmen k nnen Entspre...

Page 13: ...006 42 EC Annex II A and the amending directive 2009 125 EC we declare that the product Cold Fogger complies with these relevant regulations The following harmonized standards were applied EN 12100 1...

Page 14: ...a e 98 35435 Wettenberg Deutschland Tel 49 641 98221 0 Fax 49 641 98221 50 info conti plus www conti plus Druckfehler und Irrt mer sowie technische und ma liche nderungen vorbehalten Errors and techni...

Page 15: ...a e 98 35435 Wettenberg Deutschland Tel 49 641 98221 0 Fax 49 641 98221 50 info conti plus www conti plus Druckfehler und Irrt mer sowie technische und ma liche nderungen vorbehalten Errors and techni...

Page 16: ...uable contribution to their projects Every last detail is contem plated when developing tailor made products resulting in smart individual solutions to suit a plethora of applications and equipment Th...

Reviews: