background image

 

Maintenance 

 

 

  

 

 

 

 

 

    

33

 

 

 

 

Calibration  

Scanner calibration is very easy to perform. Calibration is carried out using the 

WIDEsystem

 program you installed with your drivers. After manually cleaning the 

scan area, you just start the 

Calibration 

wizard

 and 

let it take over. The wizard will ask you to insert a calibration sheet. Other than that, scanner calibration is 

completely automatic.  
 

NOTE: 

Cleaning and calibration are tied together. Cleaning the scanner creates the need for renewed calibration and correct calibration will always require 

a clean scan area.   
 

Calibration 
 

Turn the scanner power ON 

 
Make sure that the scanner has been turned ON and in 

Wake

 mode for at 

least 

5 minutes

 prior to calibration. The short warm-up time will ensure that 

camera and light conditions have stabilized. 
 
 

      

 
 
 
 
 
 
 
 
 
 
 
 

1

 

Summary of Contents for HD iFLEX

Page 1: ...User s Guide HD iFLEX Scanner...

Page 2: ...dia 27 Monitoring your scanner with WIDEsystem 27 Maintenance 29 About scanner maintenance 29 Overview key maintenance points 29 Cleaning the scan area glass 30 Calibration 33 Replacing Scanner Parts...

Page 3: ...system TOOLS Help After installing your drivers open WIDEsystem and press F1 Contains information on using the WIDEsystem software IMPORTANT Be sure to use the WIDEsystem TOOLS CD ROM that came with y...

Page 4: ...Overview of Scanner 3 Overview of Scanner Scanner Front View Parts you need to recognize when installing and using the scanner...

Page 5: ...Overview of Scanner 4 Scanner Rear View Parts you need to recognize when installing and using the scanner...

Page 6: ...follow the steps below in their written order Set up the scan station Your wide format flatbed scanner should be placed on a stable level and completely flat plane surface such as a sturdy table If c...

Page 7: ...on its new surface They are delivered in that position from the manufacturer 3 The 2 adjustable feet in their original position as described in step 2 are slightly shorter than the 3 fixed feet There...

Page 8: ...plete installation 3 Remove the CD when done with installation 4 To verify correct installation of WIDEsystem the WIDEsystem icon will be visible in your system tray 5 After installing WIDEsystem inst...

Page 9: ...he scanner lid to expose the scan area glass plate Cleaning the scanner Clean the internal scan area Lightly wipe the internal scan area s glass plate free of dust Use a dry lint free cloth If you det...

Page 10: ...ect power cable Connect the scanner to a power outlet Connect the power plug end of the scanner power cable to a power outlet CAUTION The scanner is equipped with a three wire pin grounding type plug...

Page 11: ...r on its left side when facing the back 2 Connect the B connector end square shaped end to a USB port on the scanner NOTE For Gigabit enabled scanner models The installation wizard will instruct you o...

Page 12: ...t on the back of the PC Using USB ports on the front can affect performance on some PC models Scanner installation The Installation Wizard starts up 1 The driver will detect the scanner and start the...

Page 13: ...s be sure to select YES if Windows asks you to allow the software to access the network Scanner Installation Set energy star idle time preference On delivery the scanner is set for automatic entry int...

Page 14: ...ll additionally require an activation code Activation codes can be obtained from your dealer or through the manufacturer s License website Follow the instructions Manual Activation below to obtain an...

Page 15: ...vation method the dialog shown on the top right appears 1 Enter you license key in the designated field 2 The key will be authenticated online right after it is entered and if valid a green tick will...

Page 16: ...to enter an activation code in the empty field Click Next to obtain an activation code 2 The Manual activation wizard will display instructions Please note the actual scanner s ID hardware ID or S N s...

Page 17: ...Change the scanner s network name optional NOTE This step only appears with licensed Ethernet supported scanners as detected during activation You may wish to change the default name of the scanner t...

Page 18: ...ou see this message For using the optimal Gigabyte interface proceed to the steps for enabling gigabyte on the scanner plus sharing it on the network If using only the USB interface you can also choos...

Page 19: ...ner s back 3 Connect the other end of the gigabit cable to your LAN 4 Open WIDEsystem if not already open double click the WIDEsystem icon in the system tray 5 Press the Refresh Scanner List button 6...

Page 20: ...SB is connected to the LAN 2 Double click on the WIDEsystem program icon and select the Network tab 3 Select the option Share the scanner on the network 4 Press the OK button to accept the settings On...

Page 21: ...or OFF The scanner s Self Test Procedure When you turn the main power ON the scanner runs a short self test procedure This takes less than one minute The LEDs on the panel will be on during the self t...

Page 22: ...hut down after idle time Manually when you hold the power button down for 3 seconds The scanner will go into wake mode When you press any button on the panel Advantages with using Wake up and Sleep mo...

Page 23: ...set the sleep mode options 1 Open WIDEsystem double click the WIDEsysem icon in the system tray 2 Select the Timer Tab 3 Select or deselect the Enter Sleep mode automatically option 4 If you do not s...

Page 24: ...als into the Scanner Load face down align at the scanner s left side Open the scanner lid Pull back the scanner lid to expose the scan area glass plate Place your document Place your document face dow...

Page 25: ...t side for a straight scan Align the document middle with the center arrow marking on the alignment bar You can use the standard size markings to position the original and determine its standard size...

Page 26: ...document and calculate the input size for you 2 Set a standard size common standard sizes are marked on the left side of the scan area at the scanner alignment bar Use these markings to determine whi...

Page 27: ...to the on line help in these applications for instructions The one touch buttons on the panel Nextimage Scan Copy button The green button duplicates the scan copy button in the Nextimage software Onc...

Page 28: ...close the cover You can also scan very thick originals by placing the original on the scanner bed and leaving the cover completely open Monitoring your scanner with WIDEsystem You installed WIDEsyste...

Page 29: ...icon select Advanced Options Rescan Hardware Bus Assign reassign applications to the scanner s one touch scan buttons or disable the one touch scan buttons altogether Open the One Touch tab to make s...

Page 30: ...eaning the scan area 2 Calibration and camera alignment Scanner Calibration is easy to perform and most of it is completely automatic Scanner calibration includes camera alignment and calibration of B...

Page 31: ...he lid to access and clean the glass Follow the instructions below Caution do not use abrasives acetone benzene or fluids that contain these chemicals Do not spray liquids directly onto the scanner gl...

Page 32: ...an area glass plate Cleaning the scan area Clean the glass 1 Clean the glass with a lint free cloth and a mild streak free glass cleaner 2 Dry the glass completely using a separate clean dry lint free...

Page 33: ...Maintenance 32 Cleaning the scan area Cover when not in use Cover the scanner with its plastic dust cover when not in use Caution Make sure the scanner power is OFF when using the dust cover 4...

Page 34: ...ert a calibration sheet Other than that scanner calibration is completely automatic NOTE Cleaning and calibration are tied together Cleaning the scanner creates the need for renewed calibration and co...

Page 35: ...tem tray to open the WIDEsystem program 2 Press the Calibrate button Calibration Select the Calibration type Select either Camera Alignment or Full Calibration Camera Alignment will align the camera h...

Page 36: ...o analyze and correct the status of the sensors calibrate black and white values and calibrate color The calibration sheet will be rescanned a number of times as the program processes data Let the pro...

Page 37: ...ding WIDEsystem WARNING FLAG White background platen replacement After receiving a warning by WIDEsystem and replacing the part be sure to reset the part replacement warning flag through WIDEsystem s...

Page 38: ...round platen is recommended WIDEsystem monitors scanner usage and will warn you when it is time for a replacement Replacing the white background platen Turn scanner power off and disconnect 1 Press th...

Page 39: ...background platen The white background platen is attached to the lid s underside It is constructed as two layers upper layer and lower layer The lower layer faces the glass The upper layer is attached...

Page 40: ...upper layer Pull the platen free Replacing the white background platen Place the new white background platen on the glass Place the new white background platen on the glass plate with its Velcro corne...

Page 41: ...ro and the white background platen s Velcro Replacing the white background platen Press on the white background platen Make sure your hands are clean Open the lid and press firmly on the new white bac...

Page 42: ...ner monitors usage of the filters and will warn you when it is time for a replacement through WIDEsystem Replacing the Dust Filters Turn scanner power off and disconnect 1 Press the main power switch...

Page 43: ...sert a screw driver or other flat tool under one of the bin s corners to snap it down and detach it from its frame Replacing the Dust Filters Replace the filter The filter soft material is inside the...

Page 44: ...Maintenance 43 Replacing the Dust Filters Reattach the bin Reattach click on the bin to its frame on the underside of the scanner 5...

Page 45: ...em double click on the system tray s WIDEsystem icon 2 Select the Info tab 3 The Info tab displays useful data about your scanner firmware 4 Firmware release Upgradeable firmware version 5 Firmware do...

Page 46: ...2 The information on your screen may include instructions and actions to remedy the error Follow the instructions on your screen 3 Look for a description of the error and remedy in this users guide s...

Page 47: ...be entered on the system as a new device without functional drivers If this is the case the scanner will be displayed in the Windows Device Manager with a yellow error icon The scanner entry must be...

Page 48: ...a description of the error in this users guide Follow the instructions provided In some cases you may need technical assistance You should contact your service provider if one or more of the following...

Page 49: ...blem persists after cleaning the scanner area and all above possibilities have been attempted summon your technical service provider Application control keys one touch do not work 1 Check the One Touc...

Page 50: ...glass plate can apply a streak along your entire scan To remedy 1 Clean your glass plate as described in this users guide 2 Most dirt on the glass plate is introduced by the documents Wipe clean the...

Page 51: ...e cabinet at the back or bottom are provided for ventilation This ensures reliable operation of the product and protects it from overheating These openings must never be blocked or covered The opening...

Page 52: ...ications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Pursua...

Page 53: ...tes that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 SJ T11363 2006 X Indicates that this toxic or ha...

Reviews: