Alerts - Edit
The
Alerts Edit
page functions the same way as scheduling Events. However, Alerts behave differently than
Events or Presets. When an Alert is sent, the iC-Net controllers will save their current power and channel
settings. When an Alert ends, the controllers will return displays to their saved setting.
Editing Modes
•
Create New Alert
– Clears values in Alert fields.
•
Edit Existing Alert
– Fills in the values of the Alert command. Change and Save.
•
Copy Existing Alert
– Copies the values of the Alert Command. Change and Save.
Alert Parameters
Add or change values to an existing or new Alert. Commands that are checked on the left will be sent; those
unchecked will not be saved or sent.
•
Name
– Enter a name for a new or copied Alert.
•
Use Preset
– uses the values of a selected Preset.
•
Zone
– Select from 15 Zones or All Zones.
•
Single Display –
use radio button to select a command to a specific display.
•
Power
- Set Power (Power On for Alerts).
•
HDTV Channel
– Enter HDTV channel in dashed (XX-X) or CableCard format (XXXXX)
•
NTSC Channel
– Enter desired analog channel (digital TVs will ignore this command)
•
Volume
during Alert-
Set volume level 0 (Mute) to 63 (Full)
•
Volume after Alert
- Set volume level 0 (Mute) to 63 (Full)
•
Control Lock
- Enable or disable display’s front-panel and IR control (not all sets have this feature)
Save the Alert. Up to 16 Alerts will appear on the Alerts Control page.
Contemporary Research