Contemporary Research ICW-STA Product Manual Download Page 21

Contemporary Research Corporation 

 

21 

   

ICW-STA

 

 

Safety Instructions 

Read before operating equipment

 

1.

 

Cleaning - 

Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol 

cleaners. Use a damp cloth for cleaning. 

 

2.

 

Power Sources - 

Use supplied or equivalent UL/CSA approved low voltage DC plug-in transformer. 

 

3.

 

Outdoor Antenna Grounding - 

If you connect an outside antenna or cable system to the product, be 

sure the antenna or cable system is grounded so as to provide some protection against voltage surges 

and built-up static charges. Section 810 of the National Electrical Code, ANSI/NFPA No. 70, provides 

information with respect to proper grounding of the mast and supporting structure, grounding of the 

lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge 

unit, connection to grounding electrodes, and requirements for the grounding electrode. 

 

4.

 

Lightning

 - Avoid installation or reconfiguration of wiring during lightning activity. 

 

5.

 

Power Lines - 

Do not locate an outside antenna system near overhead power lines or other electric light 

or power circuits or where it can fall into such power lines or circuits. When installing an outside antenna 

system, refrain from touching such power lines or circuits, as contact with them might be fatal. 

 

6.

 

Overloading - 

Do not overload wall outlets and extension cords as this can result in a risk of fire or 

electric shock. 

 

7.

 

Object and Liquid Entry -

 Never push objects of any kind into this product through openings as they 

may touch dangerous voltage points or short out parts, resulting in a fire or electric shock. Never spill 

liquid of any kind on the product. 

 

8.

 

Servicing - 

Do not attempt to service this product yourself as opening or removing covers may expose 

you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. 

 

9.

 

Damage Requiring Service - 

Unplug this product from the wall outlet and refer servicing to qualified 

service personnel under the following conditions: 

 

When the power supply cord or plug is damaged. 

 

If liquid spills or objects fall into the product. 

 

If the product is exposed to rain or water. 

 

If the product does not operate normally by following the operating instructions. Adjust only those 

controls that are covered by the operating instructions. An improper adjustment of other controls may 

result in damage and will often require extensive work by a qualified technician to restore the product 

to its normal operation. 

 

If the video product is dropped or the cabinet is damaged. 

 

When the video product exhibits a distinct change in performance, this indicates a need for service. 

 

*

 Note to CATV system installer

: This reminder is provided to call CATV system installer's attention to 

Article 820-40 of the National Electrical Code (Section 54 of Canadian Electrical Code, Part I), that provides 

guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the 

grounding system of the building as close to the point of cable entry as possible.

 

 

 

 

 

 

Summary of Contents for ICW-STA

Page 1: ...avenport Rd Suite113 Dallas TX 75252 USA Tel 972 931 2728 888 972 2728 Fax 972 931 2765 Web www crwww com www contemporaryresearch com Product Manual ICW STA Video Display Controller Ver 2 0 January 2...

Page 2: ...iCW Net Connection 6 A V Setup 6 External IR Sensor 7 Programming the IC RC Remote 7 Audio Settings 7 On Screen Menus 8 RS 232 Control Protocol 9 Overview 9 Command String Structure 9 RS 232 Commands...

Page 3: ...tworked with up to 4000 TV and Video Display controllers For custom systems applications all ICW STA units and other CR devices can be accessed from a single RS 232 port on an ICC HE or ICW HE Head En...

Page 4: ...North American version includes UL CSA listed wall power supply RS 232 Control Not operational in this model iCW Net RJ 45 input for iCW Net connection IR In 3 5mm stereo jack for optional IR RXC IR...

Page 5: ...off On LED Blinks Net LED Blinks once per second when it is receiving network data LED Response Off DC power to unit missing or other internal power problem Solid On no network communication Blinks on...

Page 6: ...1 Connect the RF Coax cable into the Antenna Cable input on the STA 2 Connect the iCW Net RJ 45 plug into the iCW Net input on the STA 3 If the iCW Net signal is operating the Net LED will now blink...

Page 7: ...set the format of IR codes in the remote 1 Press and hold the Select button and a numeric key for the code below 2 Release the two keys at the same time 3 The remote will now send the selected codes 4...

Page 8: ...Display the unit s Device At this point you can use the Channel Down key as a Delete key enter a new device with the remote s numeric keypad then hit Enter to save the new number 65478 Reset unit simi...

Page 9: ...system Zones 1 16 are used for CR TV Controllers Video Display Controllers and Tuners As it s unlikely any system will use all 4000 devices this may be a good device standard for your system as well...

Page 10: ...age 8 Treble Gain S9 A5 dh dl 3 S9 mode 7 bytes Sets treble gain see chart on page 8 Ts Qs T series channel commands select a channel and display the channel label on the TV while Q series commands do...

Page 11: ...dl 8 TR 82 5 87 11 sets channels 2 5 and 7 11 You can specify a range using MSB bit for the first channel the next byte is the last Channel Labels TN A5 dh dl ncb TN channel label variable bytes Stor...

Page 12: ...patibility with Smart TVs mixed in the same system that can display other colors and fonts Fast Write DN A5 dh dl ncb DN text variable bytes Clears display writes specified text starting at column 1 r...

Page 13: ...ple commands or parameters are set apart by brackets Commas separate the bytes but are not part of the protocol Double quotes enclose the command string but are not part of the protocol Command format...

Page 14: ...tes are in msh and msl Menu Parameter high and low bytes are in mph and mpl A Menu command is initiated by pressing the Menu key followed by a numeric entry then the Enter or Channel Up key During the...

Page 15: ...tiple commands there would be a long delay between the first and last command One command instant response is easier As we noted before ABC Media Retrieval Systems reserve Zone 0 for devices used in t...

Page 16: ...ion whichever suits the application iC Net Zone Zone Room Device 1 W 1st Floor 256 W151 260 W152 261 W153 262 W154 263 2 W 2nd Floor 512 W251 560 W252 561 W253 562 W254 563 3 E 1st Floor 768 E151 860...

Page 17: ...A Typical RF and ICC Net Signal Flow The diagram below shows the structure of a typical Contemporary Research media retrieval system One of the key aspects for iCC Net communication is to provide a fo...

Page 18: ...iple iCW Net devices Open wiring runs do not need termination Head End iCW Net 1 Screw Terminals iCW Series iCW Net RJ 45 PWR RXD RXD TXD TXD GND 8 7 6 5 4 3 2 1 TXD TXD GND RXD RXD NC NC NC 8 7 6 5 4...

Page 19: ...75 38mm deep Size Short Bracket 1 0 22mm wide x 1 75 38mm height 1RU x 1 75 38mm deep Weight 3 25 oz 0 148kg Enclosure All aluminum with durable black powder coat paint Hardware Qty 4 CS Phillip Flath...

Page 20: ...nit with three 3 supplied 4 40 by 1 4 silver colored panhead screws and split lock washers Note that only one side of the second 232 STA has the 3 built in nuts to accept the screws above 3 Reinstall...

Page 21: ...tric shock 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric sho...

Page 22: ...ages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be w...

Reviews: