Safety Instructions 

Read before operating equipment. 

 

1.

 

Cleaning - 

Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol 

cleaners. Use a damp cloth for cleaning. 

 

2.

 

Power Sources - 

Use supplied or equivalent UL/CSA approved low voltage DC plug-in transformer. 

 

3.

 

Outdoor Antenna Grounding - 

If you connect an outside antenna or cable system to the product, be 

sure the antenna or cable system is grounded so as to provide some protection against voltage surges 

and built-up static charges. Section 810 of the National Electrical Code, ANSI/NFPA No. 70, provides 

information with respect to proper grounding of the mast and supporting structure, grounding of the lead-
in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge unit, 

connection to grounding electrodes, and requirements for the grounding electrode. 

 

4.

 

Lightning

 - Avoid installation or reconfiguration of wiring during lightning activity. 

 

5.

 

Power Lines - 

Do not locate an outside antenna system near overhead power lines or other electric light 

or power circuits or where it can fall into such power lines or circuits. When installing an outside antenna 

system, refrain from touching such power lines or circuits, as contact with them might be fatal. 

 

6.

 

Overloading - 

Do not overload wall outlets and extension cords as this can result in a risk of fire or 

electric shock. 

 

7.

 

Object and Liquid Entry -

 Never push objects of any kind into this product through openings as they 

may touch dangerous voltage points or short out parts, resulting in a fire or electric shock. Never spill 

liquid of any kind on the product. 

 

8.

 

Servicing - 

Do not attempt to service this product yourself as opening or removing covers may expose 

you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. 

 

9.

 

Damage Requiring Service - 

Unplug this product from the wall outlet and refer servicing to qualified 

service personnel under the following conditions: 

 

When the power supply cord or plug is damaged. 

 

If liquid spills or objects fall into the product. 

 

If the product is exposed to rain or water. 

 

If the product does not operate normally by following the operating instructions. Adjust only those 

controls that are covered by the operating instructions. An improper adjustment of other controls may 
result in damage and will often require extensive work by a qualified technician to restore the product 

to its normal operation. 

 

If the video product is dropped or the cabinet is damaged. 

 

When the video product exhibits a distinct change in performance, this indicates a need for service. 

 

*

 Note to CATV system installer

: This reminder is provided to call CATV system installer's attention to 

Article 820-40 of the National Electrical Code (Section 54 of Canadian Electrical Code, Part I), that provides 

guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the 

grounding system of the building as close to the point of cable entry as possible.

 

 

 
 
 
 

Summary of Contents for ICC2-IRC

Page 1: ...avenport Road Suite 113 Dallas TX 75252 Phone 972 931 2728 Toll Free 888 972 2728 Fax 972 931 2765 E Mail Sales crwww com Website www crwww com Product Manual ICC2 IRC IR TV Controller Ver 7 8 August...

Page 2: ...iCC Net Operation 6 TV Power Sensing 6 A V Setup 7 IR Control Wiring 7 IR Mode and Power Sensing 7 Programming the IC RC Remote 7 On Screen Setup Menus 8 IR Control Chart 9 RS 232 Control Protocol 10...

Page 3: ...ost brands of TVs from IR control port o Creates on screen channel labels messages text menus and feedback using onboard character generator o Supports closed captioning text o Receives wireless comma...

Page 4: ...es UL CSA listed wall power supply Power Sensor 3 5mm jack for optional CC HSD scan sensor or 5V logic level input Aux Factory Option 3 5mm jack sends volume control data to optional 232 Amp IR Out 3...

Page 5: ...sor input does not see scanning activity the Power LED blinks rapidly Net LED Blinks when it is receiving network data LED Response Off DC power to IRC missing or other internal power problem Solid On...

Page 6: ...but is not sensing the presence of TV scanning operation 3 Insert the CC HSD Scan Sensor plug into the IRC Power Sensor jack 4 Turn on the TV using the TV s power button 5 Move the CC HSD sensor block...

Page 7: ...IRC to set IR options and TV Power sensing Note this affects the front panel sensing not an external IR sensor Turning off both sensors would limit sensing to the external IR sensor only If you have...

Page 8: ...IR receive in 0 disable 4 Enable IR output carrier 0 no carrier 8 Set power sensor for high sensitivity 0 low sensitivity 16 Set IR output for high current 0 low current Add up the values and enter th...

Page 9: ...3 21 Zenith LG Discrete PDP LCD Discrete Added DVI input 4 2 22 Philips Discrete PDP LCD TV Discrete 3 3 23 JVC Discrete PDP LCD TV Discrete 3 3 24 Sampo Discrete NetTV Gateway ViewSonic PDP LCD TV D...

Page 10: ...ers Video Display Controllers and Tuners As it s unlikely any system will use all 4000 devices this may be a good device standard for your system as well The Remote RS 232 port on the Head End Network...

Page 11: ...off 1 alpha labels on IR Device Type T1 A5 dh dl 2 T1 type 7 bytes Sets IR device type Identical to on screen menu 45700 command on Page 8 Specify value to match make and model of video display Volume...

Page 12: ...VDC external A V input also selects TV video input 127 Select S Video Input 0 Blank video output to TV 255 Unblank TV video restore to previous channel Tip Not all inputs are available on every TV mak...

Page 13: ...ange using MSB bit for the first channel the next byte is the last Channel Labels TN A5 dh dl ncb TN channel label variable bytes Stores an ASCII string as the channel label The text will appear brief...

Page 14: ...ibility with Smart TVs mixed in the same system that can display other colors and fonts Fast Write DN A5 dh dl ncb DN text variable bytes Clears display writes specified text starting at column 1 row...

Page 15: ...ands or parameters are set apart by brackets Commas separate the bytes but are not part of the protocol Double quotes enclose the command string but are not part of the protocol Command format dh dl n...

Page 16: ...e in msh and msl Menu Parameter high and low bytes are in mph and mpl A Menu command is initiated by pressing the Menu key followed by a numeric entry then the Enter or Channel Up key During the Menu...

Page 17: ...multiple commands there would be a long delay between the first and last command Sending one command with instant response is far easier As we noted before ABC Media Retrieval Systems reserve Zone 0 f...

Page 18: ...uits the application iC Net Zone Zone Room Device 1 W 1st Floor 256 W151 257 W152 258 W153 259 W154 260 2 W 2nd Floor 512 W251 513 W252 514 W253 515 W254 516 3 E 1st Floor 768 E151 769 E152 770 E153 7...

Page 19: ...ical RF and ICC Net Signal Flow The diagram below shows the structure of a typical Contemporary Research media retrieval system One of the key aspects for iCC Net communication is to provide a forward...

Page 20: ...s our optional RK2 Brackets to mount the IRC to the TV as shown below Some combine the two approaches using Velcro during the initial phase of installation then securing with brackets when testing and...

Page 21: ...hock 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock Nev...

Page 22: ...re sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived...

Reviews: