Contemporary Research ICC-HE Product Manual Download Page 1

 

 

17630 Davenport Road, Suite 113  • Dallas, TX  75252 

Phone:972-931-2728 • Toll-Free: 888-972-2728  • Fax: 972-931-2765  

E-Mail: 

[email protected]

   •  Website: www.crwww.com 

Product Manual 

 

ICC-HE 

Head-End Network Controller 
Ver. 3.1  June 27, 2007

Summary of Contents for ICC-HE

Page 1: ...port Road Suite 113 Dallas TX 75252 Phone 972 931 2728 Toll Free 888 972 2728 Fax 972 931 2765 E Mail Sales crwww com Website www crwww com Product Manual ICC HE Head End Network Controller Ver 3 1 Ju...

Page 2: ...O Port Connection 7 RS 232 Terminal Commands 8 RS 232 Control Protocol 9 Overview 9 Command String Structure 9 Command format 9 RS 232 HE Commands 10 RS 232 Controller Commands 11 General Commands 11...

Page 3: ...g runs of up to 3 300 feet 1 Km In addition iCW Net data can be sent to remote locations over RS 422 fiber and RS 232 video conferencing codec data ports Networks with up to 4 000 TVs through wired iC...

Page 4: ...gnal DIP Off On 1 RF In Low RF In High 2 3 4 5 6 Baud 7 Baud 8 Baud Baud 6 7 8 38 400 ON ON ON 19 200 OFF ON ON 9 600 ON OFF ON 4 800 OFF OFF ON 2 400 ON ON OFF 1 200 OFF ON OFF Default setting Net LE...

Page 5: ...o provide DC on off Dry closure 2 close pins 3 4 for dry contact to external power relay AMX PC1 or similar Sense closure 3 4 on Input 1 trigger control system to power off for all rooms iCW Net Conne...

Page 6: ...level 0 to 15 dBmV nominal RF Out F female 75 ohm impedance RF to CATV distribution to TVs tuners and controllers Data Transmit Mid band VHF 74 7 MHz narrow band signal between channels 4 and 5 80 KHz...

Page 7: ...ommand p8 a few times to measure the level of background RF compared to the current Sensitivity setting DIP switch 1 p4 7 Set one iC Net controller to constantly transmit using iC ToolKit Send the AR...

Page 8: ...SP Displays number of present devices and number of devices expected Example Response Num Devs Present 1 Num Devs Expected 53 Scan and Show SZ Scans iC Net and displays list of all 2 way devices found...

Page 9: ...control system Zones 1 16 are used for CR TV Controllers Video Display Controllers and Tuners As it s unlikely any system will use all 4000 devices this may be a good device standard for your system a...

Page 10: ...7 bytes Turns the two internal closures on and off Closure 1 is typically used to control the optional buzzer Closure 2 typically used to control an external camera power relay A5 0 0 3 Y10 turns Clo...

Page 11: ...l to on screen menu 45700 command for IR format controllers X X Closures Y A5 dh dl 3 Y I 0 Port 7 bytes Turns the two internal closures on and off Closure 1 is typically used to control the optional...

Page 12: ...X X Mute Off VX A5 dh dl 2 VX 6 bytes Unmutes volume X X Toggle Mute VT A5 dh dl 2 VT 6 bytes Toggles between mute on and off X X Save Level VW A5 dh dl 2 VW 6 bytes Save current volume level default...

Page 13: ...annel Down QD A5 dh dl 2 QD 6 bytes Tunes to next channel down in Tune Ring X X X X X Q Channel Previous QP A5 dh dl 2 QP 6 bytes Tunes to previous channel in Tune Ring X X X X X Force Q Chan QC A5 dh...

Page 14: ...bytes This command stores a Tune Ring a series of preset channels accessed by channel up down commands Ex1 A5 dh dl 6 TR 5 4 8 11 sets ring to channels 5 4 8 and 11 Tip The ring follows the stored or...

Page 15: ...olors and fonts 5 5 X X Advanced The following commands provide advanced CG text operation Fast Write DN A5 dh dl ncb DN text variable bytes Clears display writes specified text starting at column 1 r...

Page 16: ...enclosed in single quotes Numbers shown that are not in single quotes are a single decimal byte Parameters shown in brackets are single byte A series of multiple commands or parameters are set apart...

Page 17: ...ponse and activate a programmed event 101 Reset button pressed 229 Reset button released 102 Emergency button pressed 230 Emergency button released 103 I O 1 input closed 231 I O 1 input opened 104 I...

Page 18: ...Pause 4 Fast Forward 5 Rewind 8 Record IR Key K dh dl 2 K IR Key 6 bytes Sent when unit receives a new key command is pressed 10 23 or released 0 from the IR remote 0 Release 102 Timer 10 19 Numeric...

Page 19: ...followed by a numeric entry then the Enter or Channel Up key During the Menu process the Channel Down key acts as a backspace or delete key Some selections that need only a single numeric entry and wi...

Page 20: ...o the hassles of creating multiple commands there would be a long delay between the first and last command One command instant response is easier ABC Media Retrieval Systems reserve Zone 0 for devices...

Page 21: ...plication iC Net Zone Zone Room Device iC Net Zone Zone Room Device 1 W 1st Floor 256 5 Coffee Areas 1280 W151 257 G100 1281 W152 258 G150 1282 W153 259 G151 1283 W154 260 6 Day Care 1536 2 W 2nd Floo...

Page 22: ...structure of a typical Contemporary Research media retrieval system One of the key aspects for iCC Net communication is to provide a forward and return sub channel path for data if you re using 2 way...

Page 23: ...ic shock 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock...

Page 24: ...es are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be wai...

Page 25: ...5 276 0138 585 25 65 469 25 468 0234 777 25 103 667 25 666 0333 97 103 25 102 0051 103 25 34 283 25 282 0141 591 25 66 475 25 474 0237 783 25 104 673 25 672 0336 Mid 35 289 25 288 0144 597 25 67 481 2...

Reviews: