4. Functions
32
DIG-100M1002-PCI
All the data, which combines pre-trigger sampling and post-trigger sampling, can be acquired.
Waveform judgment instrument mode
It is the mode that assumes the usage as waveform judgment instrument.
It is a function to compare the data used for waveform judgment and set beforehand with the actual
input waveform, so as to perform one by one, pass or fail judgment of the record waveform
automatically.
In waveform judgment instrument mode, it is possible to count the number of generation times of the
waveform judgment result (PASS/FAIL).
A limit value is set to the counter, when the number of generation times of PASS or FAIL reached the
limit, the digitizer operation is stopped and the signal is output to outside.
Moreover, by acquiring the conversion data and the waveform judgment result, the PASS/FAIL result of
the acquisition data can be confirmed by a record unit.
And a detailed analysis for judgment results such as whether each sample data exceeding the upper
bound/lower bound value of the mask data, is also possible.
The figure is a data acquisition image in the waveform judgment instrument mode.
The record loss is inhibited.
The digitizer operation stops when all records cannot be acquired by exceeding the limit of the
processing performance.