Summary of Contents for CONPROSYS CPS-MM-LC

Page 1: ...al Hardware CONTENTS Measurement Module CPS MM LC Introduction 4 Safety Precautions 10 Product Nomenclature and Function 16 Installation 20 Appendix 35 Optional Products 41 Customer Support and Inquir...

Page 2: ...Description of Product Components 18 1 Stack Bus 18 2 LED Indicator 18 3 ZCT Connection 19 4 Voltage Measurement Connector 19 Installation 20 1 Install the Product 21 1 Installation Conditions 21 2 Se...

Page 3: ...3 Table of Contents 1 Optional Products 42 Customer Support and Inquiry 43 1 Services 44 Index 45...

Page 4: ...4 Introduction This section provides necessary information of the product such as the outline bundled items and manuals before actual use...

Page 5: ...ad this when setting up the product This describes the required items for setup and configuration procedure Download from the Contec website PDF Reference Manual Hardware Read this when operating the...

Page 6: ...roduct visit our website to check the firmware version and update to the latest one if necessary Updating firmware to the latest version will resolve troubles and stabilize the operation Download http...

Page 7: ...ee phase alternating current power Set this module to operate along with the CONPROSYS series configurable type CPU module controller It has a function useful for early deterioration discovery in the...

Page 8: ...product can be set either in front of or behind the inverter The measurement method of TANASHIN DENKI CO LTD is applied for this product No base board required As the product requires no base board f...

Page 9: ...amaged or missing items contact your retailer Product 1 Product Guide 1 Warranty Certificate 1 Serial Number Label 1 4 pin Connector 1 ZCT Unit 1 This product is verified in conformity with our recomm...

Page 10: ...10 Safety Precautions Understand the following definitions and precautions to use the product safely Never fail to read them before using the product...

Page 11: ...erstand the meanings of these labels to operate the equipment safely DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNI...

Page 12: ...tion provided by the equipment may be impaired The product is not intended for use in aerospace space nuclear power medical equipment or other applications that require a very high level of reliabilit...

Page 13: ...f the product must be used in such an environment install it on a dust proof control panel for example Avoid using or storing the product in locations subject to shock or vibration that exceeds range...

Page 14: ...ws and municipal ordinances Always attach the end cover while power is active The product is an open type device a device designed to be housed inside other equipment and must always be mounted inside...

Page 15: ...not disassemble the ZCT unit otherwise troubles may be caused Regardless of the foregoing statements CONTEC is not liable for any damages whatsoever Including damages for loss of business profits aris...

Page 16: ...16 Product Nomenclature and Function This section describes product component names and their functions pin assignment of each connector...

Page 17: ...gure below No Name Function 1 Stack Bus Used for power supply and communication with the configurable type module 2 LED Indicator This indicates status of the product 3 ZCT Connector Used to connect t...

Page 18: ...the PWR LED is turned off before setting or removing the devices 2 LED Indicator Status of the product is indicated by ON OFF and flashing of LED The meaning of each LED is described below Color and D...

Page 19: ...of each phase of three phase power supply base on to the ground potential Use the 4 pin connector included in the package to connect to external power Connector type PHOENIXCONTACT GMSTB 2 5 HCV 4 ST...

Page 20: ...20 Installation This section describes how to mount the product on a DIN rail and to connect to an external device with a cable...

Page 21: ...Install the Product 1 Installation Conditions Installation Orientation Install the product in the orientations shown below 0 C Other orientations may cause problems such as malfunctions due to inadequ...

Page 22: ...operational malfunction may occur if there is other device generating high heat the radiation will influence the product to increase its temperature Do not install this product into the fully sealed s...

Page 23: ...oller on DIN rail in order to avoid the trouble Always confirm the PWR LED is turned off before setting or removing the modules Always check the module is firmly fixed on DIN rail with hooks when sett...

Page 24: ...the side rail of the controller or another module that is already mounted When the rails fit slide the setting module all the way toward the DIN rail 4 Fix and secure the module on the DIN rail by loc...

Page 25: ...LC Reference Manual Hardware 25 How to Remove 1 First slide the attached end cover from the configurable type module to remove it 2 Unlock the hooks of the module If the hooks are stuck use a slotted...

Page 26: ...r as leverage Insert a slotted screwdriver the point should be smaller than 4 5mm into a hole see the figure below By using the screwdriver as leverage move it upward in the direction of the arrow to...

Page 27: ...Installation CPS MM LC Reference Manual Hardware 27 3 With the hooks unlocked pull the module toward you 4 Put back the end cover to the controller...

Page 28: ...ecure the ZCT unit Recommended screws M4 captive washer SW JIS flatW binding head screw Length 14 mm or longer Recommended tightening torque 1 2 1 5 N m Decide the most appropriate tightening torque t...

Page 29: ...art by turning screws with a slotted driver to prevent it from disconnecting CAUTION Removing the connector plug by grasping the cable can break the wire Always grasp the connector to remove it Tighte...

Page 30: ...ngth Shorter than 3 0 meters Refer to Voltage Measurement Connector in the page 19 for details of the voltage measurement connector and pin assignment Connecting example with three phase Delta 3 wire...

Page 31: ...onnect phases L1 L2 and L3 as well as the ground terminal with the voltage input terminal L1 T1 L2 T2 L3 T3 and REF respectively Then put three cables of L1 L2 and L3 through the ZCT unit AT this time...

Page 32: ...e measuring Measuring may not start if the cable is unconnected If the connecting cable is affected by the noise measuring may not be done accurately Place the connecting cable away from the noise sou...

Page 33: ...n the page 19 for details of the voltage input connector and pin assignment Connecting example with inverter powered by three phase Delta 3 wire three phase corner grounded system When connecting to t...

Page 34: ...terminal L1 T1 L2 T2 L3 T3 and REF respectively Then put three cables of T1 T2 and T3 through the ZCT unit AT this time these cables should be connected to the three phase induction motor CAUTION The...

Page 35: ...35 Appendix This section lists the specifications and the physical dimensions of the product and the details of model name...

Page 36: ...unded neutral system Rated input voltage 2 Phase voltage10VAC 600VAC 50Hz 60Hz three phase Measurement Leakage current range All equipment measurement 0 000mA 999 999mA Inverter output part measuremen...

Page 37: ...nt connector and stack bus CAUTION You can set the modules as you desire to the configurable controller up to 16 modules The total current consumption of the modules should be less than 3 3A Function...

Page 38: ...2 Level 2 Air 8kV IEC61000 4 2 Level 3 EN61000 4 2 Level 3 Vibration resistance The product alone 8 Sweep resistance 10 57Hz 7 semi amplitude vibration 0 15mm 57 150Hz 2 0G 40minutes each in X Y and Z...

Page 39: ...Appendix CPS MM LC Reference Manual Hardware 39 2 Physical Dimensions 1 Product 2 ZCT unit 25 2 124 8 14 18 4 4 14 18 mm 94 7 5 1 55 100 4 74 5 37 2 mm 115 9...

Page 40: ...LC Reference Manual Hardware 40 3 The Details of Model Name Details of the model name are described below No Item Description 1 Model MM Measurement Module 2 Function LC Leakage current CPS MM LC CONP...

Page 41: ...41 Optional Products This section lists optional items that can be used along with the product...

Page 42: ...MCS341 DS1 131 Configurable type CPU module OPC UA server MT Connect CPS MCS341G DS1 130 Configurable type CPU module 3GWAN CPS MCS341Q DS1 131 Configurable type CPU module 920MHz LAN DIN rail fitting...

Page 43: ...43 Customer Support and Inquiry CONTEC provides the following support services for you to use CONTEC products more efficiently and comfortably...

Page 44: ...e useful information including product manuals that can be downloaded through the Contec website Download https www contec com download You can download updated driver software firmware and differenti...

Page 45: ...45 Index...

Page 46: ...Index CPS MM LC Reference Manual Hardware 46 Revision History MONTH YEAR Summary of Changes September 2018 The First Edition...

Page 47: ...5 0025 Japan https www contec com No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD CPS MM LC Reference Manual Hardware NA062...

Reviews: