3. Hardware Setup
BX-320 User’s manual
23
Installation Requirements
There are limits to the ambient temperature range depending on the installation orientation.
Be sure that the operating temperature is within the range specified in the installation environment
requirement by making space between the product and device that generates heat or exhaust air.
Installable directions at operating temperature 0 - +50°C: (1)
(When using 1000BASE-T: 0 - +45°C)
Installable directions at operating temperature 0 - +35°C: (2)
(When using 1000BASE-T: 0 - +30°C)
Installable directions that is unusable: (3), (4), (5), (6)
Figure 3.11. Installation Orientation
-
Note that even though the ambient temperature is within the specified range, an operational
malfunction may occur if there is other device generating high heat; the radiation will influence the
product to increase its temperature.
-
When the installation orientation is (1) and the ventilation holes on the bottom may become blocked,
use the included rubber feet.
CAUTION