Consort Heatflow BFH2T Using Manual Download Page 1

 

 

57000584 Iss 06 

I

NSTALLATION

 

Ensure  the  electricity  supply  is  disconnected  from  any  relevant  fixed  wiring  before  commencing  the 
installation.  Ensure that the mains supply voltage is as stated on the rating label. 
The supply circuit must be adequate for the input of the appliance.  
 

I

MPORTANT

 

When installed in a bathroom the unit must not be connected via a plug and socket. 
The heater must also be located in the appropriate zone of the bathroom, in accordance with section 601 of 
the Wiring Regulations BS 7671).  The appliance should be fitted horizontally such that the cable entry is 
uppermost and the pullcord is at the bottom.  The unit must be mounted a minimum of 1.8 metres from the 
floor, also a minimum of 150 mm below ceiling level or any other projecting surface.  It must also not be 
less than 250 mm from any adjacent projecting surface.  The unit must not be located immediately below a 
fixed socket outlet.  This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision  or  instructions  concerning  use  of  the  appliance  by  a  person  responsible  for  their  safety.  
Children  should  be  supervised  to  ensure  that  they  do  not  play  with  the  appliance.    The  heater  is  to  be 
installed so that the switches and other controls cannot be touched by a person in the bath or shower.  The 
heater must not be installed in front of a socket-outlet.  Means for disconnection must be incorporated in 
the fixed wiring in accordance with the wiring rules.  If the supply cord is damaged, it must be replaced by 
the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 
 
Ensure that when in use the airstream is not obstructed by a cupboard or similar object. 

WARNING

 – THIS APPLIANCE MUST BE EARTHED 

 

 

WARNING

  –  DO 

NOT

  PLACE  AEROSOLS  OR  SIMILAR  CONTAINERS  OR  MATERIALS 

SUSCEPTIBLE TO HEAT IN THE DIRECT AIRSTREAM. 
 

C

ONNECTION 

T

T

HE 

M

AIN 

S

UPPLY

 

Electrical  installation  should  be  carried  out  by  a  competent  installer, preferably  registered  with  NICEIC 
(National Inspection Council for Electrical Installation Contracting) in accordance with the 16 edition of 
the IEE Wiring Regulations, (BS.7671) and any relevant Local Authority Bye-Laws. 
The  heater  is  fitted  with  a  3-core  mains  supply  cable  and  should  be  permanently  connected  to  the 
electricity supply via a double pole switch having 3 mm gap on each pole. 
A  switched  Fused  Connection  unit  to  BS.1363  Part  4  is  a  recommended  mains  supply  connection 
accessory to ensure compliance with safety requirements applicable to fixed-wiring installation. 
 

M

OUNTING 

P

ROCEDURE

 

Using  the  mounting  bracket  supplied  as  a  template, 
position it horizontally a minimum of 1.92 m from floor to 
underside  of  bracket  and  mark  the  position  of  the  three 
fixing holes (ref A. in diagram). 
Drill and plug the wall suitable for No 8 screws. 
Insert  the  two  keyhole  screws  in  wall  leaving 
approximately 2 mm gap between head and wall. 
Secure  the  mounting  bracket  to  the  appliance  using  the  3 
No 6 screws supplied (ref B in diagram). 
Position the appliance on the partially inserted wall screws 
and  secure  the  third  wall  screw  immediately  above 
appliance. 

C

ONTROLS

 

The BFH2T has a heat loading of 2 kW.  The heater is controlled by a pullcord operated on/off switch.  A 
neon indicator when lit shows that the unit is operational. 
The appliance is fitted with an Electronic Safety Control (ES).  This is a safety device which switches off 
the heater if for any reason the appliance overheats.  The ES Control can only be re-set after the appliance 
has cooled down.  In order to re-set the ES Control proceed as follows:- 

 

 

Switch off appliance by means of pullcord and leave for approximately 5 minutes. 

 

Switch appliance back on and ES Control will re-set. 

 

Ensure  that  the  appliance  is  functioning  correctly.    If  the  ES  Control  operates  again,  the  appliance 
should be checked by a competent electrician. 

 

T

HERMOSTAT 

C

ONTROL

 

The BFH2T is fitted with a thermostat. 
 

o  set  the  thermostat  to  the  required  temperature,  turn  the  control  knob  fully  clockwise.    When  the 

desired room temperature is reached, turn the knob slowly anti-clockwise and when the thermostat ‘clicks’ 
off, leave the control at this setting.  Thereafter, the fan heater will control the heat output automatically. 
To set the  heater to the Frost Watch  mode, rotate the thermostat control knob fully to the lowest setting 
(N

o

 1).  Thereafter the heater will trip in if the temperature drops sufficiently.  The heater needs to be in 

the ‘ON’ mode with the neon indicator light illuminated for this function to operate.

 

 

T

HERMOSTAT 

C

ONTROL 

K

NOB

 

 
 
 

 

 

 

 

 

 

I

Y

OUR 

H

EATER 

D

OES 

N

OT 

W

ORK

 

 

Check re-set of E.S. Control as described under ‘controls’. 

 

Check that the plug is firmly pushed into the wall socket with the socket switched ‘on’. 

 

Check that the socket is live by using another appliance in it.  (If it is not live, check the fuse at the 
distribution board). 

 

Check that the plug is wired correctly. 

 

Check that the fuse has not blown.  (This can be done by replacement with another suitable fuse). 

 

If you are replacing a fuse in the plug, a 13 Amp fuse approved by A.S.T.A to BS 1362 must be used. 

 

Should  none  of  the  above  remedies  work,  than  disconnect  heater  from  the  mains  and  consult  an 
accredited service agent. 

 

Do 

NOT 

attempt to repair the heater or unscrew the outer casing yourself. 

 

 

Reviews: