1.    Features 

1.1 

Time 

 

 

 

-        Radio Controlled Time   

 

  

 

 

                   

Perpetual Calendar Up to Year 2099 

 

  

 

                 

 

Day of week in 8 languages user selectable 

                                                            -      Daily Alarm Snooze Function                               

 

 

  

 

 

 

 

 

 

 

 

 

1.2 

Humidity

 

 

                 

-      Indoor & Outdoor measurable range: 20 ~ 99% 

 

 

 

 

                -      Outdoor Humidity Record from Start-Up/Reset, and the corresponded time 

                                                            -      24 Hours Min/Max Display for Outdoor Humidity 

 

 

1.3 

Temperature

   

   

-

  Indoor measurable range: -10~ 50°C   

 

  

 

 

 

        -      Measures °C / °F user selectable 

 

  

 

 

-

Outdoor measurable range: -20 ~ 50°C 

   

 

 

         

-      Outdoor Temperature Record from Start-Up/Reset, and the corresponded time 

                                                    -      24 Hours Min/Max Display for Outdoor Temperature 

                                                    -      Comfort Indicator 

 

 

1.4 

Wireless Outdoor Sensor

 

Low-battery indicator for Outdoor Thermo Sensor 

 

  

 

 

 

Wall Mount or Table Stand   

 

  

 

 

 

                - 

One Wireless Thermo Sensor Included   

 

  

 

 

                   

433MHz RF transmitting frequency 

 

  

 

 

                   

100 meter    transmission range in an open area 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.    Main Unit Appearance 

 

 
2.1 Part A- LCD 

 

A1: Comfort Indicator 
A2: Indoor Temperature 
A3: Indoor Humidity 
A4: Outdoor Temperature 
A5: Outdoor Humidity 

A6: Temperature Memory 
A7: Humidity Memory 
A8: Time 
A9: Radio Controlled Icon 
A10: Date 

               

2.2 Part B- Buttons 

B1: “

MODE 

“button

                                             

B2: “

AL ON/OFF

” button

 

B3: “

MEM

” button                                 

 

B4: “

SNOOZE/LIGHT

” button

 

B5: “

RESET

” button                       

 

B6: “

SEARCH

” button

 

B7: “

ALERT

” button                                             

 

B8: “

ϰ

/C/F/

 button               

B9: “

ϧ

” button

   

 

2.3 Part C- Structure

 

C1: Battery Compartment   
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

 

 

2XWGRRU7KHUPR6HQVRU

 

D1: Transmission Indication LED                     
D2: Outdoor Temperature display 
D3: Outdoor Humidity display                       
D4: Battery Compartment 

D5: Wall Mount Hole                                     

D6: “RESET”

 button                                         

D7: “C/F” button                                           

                               

D8: Stand 

 

4. Getting Started: 

4.1 Main Unit: 

l

 

Open main unit battery compartment cover [C1] 

l

 

 Insert 2 x A

A batteries observing polarity [ “+” and “ –“ marks]

 

l

 

 Replace main unit battery compartment cover 

l

 

 Use a pin to press the RESET [B5] button on the rear of the main unit, the main 

unit is now ready for use 

 

4.2 Outdoor Thermo Sensor 

l

 

Batteries compartment (D4) of thermo sensor is locating behind the back cover,   

l

 

Insert 2 x AA

A batteries observing polarity [ “+” and “–“ marks]

 

 

5. Installation 

5.1 Main Unit 

The main unit can be placed onto any flat surface. 

 

5.2 Outdoor Thermo sensor 

The remote sensor should be securely mounted onto a horizontal surface.   

Note: 

Transmissions  between  receiver  and  transmitter  can  reach  up  to  100m  in 

open area.    Open Area: there are no interfering obstacles such as buildings, trees, 
vehicles, high voltage lines, etc. 
 

6. Thermometer 

 

 

6.1 RF Transmission Procedure: 

l

 

The  main unit  automatically  starts  receiving transmission  from  outdoor  thermo 

sensor for outdoor temperature & humidity after batteries inserted. 

l

 

The outdoor sensor will automatically transmit temperature and humidity signal 

to the main unit after batteries inserted.   

l

 

If main unit failed to receive transmission from outdoor thermo sensor in first 3 

minutes after the batteries inserted 

(“

- - . 

display on the LCD), 

hold “

SEARCH

” 

button (B6) for 3 seconds to receive transmission manually. 

RF icon “

 flashes 

on the LCD 

 
6.2 Temperature & Humidity 

(1) Past 24 Hours Maximum / Minimum Outdoor Temperature and Humidity 

l

 

After  start  up,  the  unit  automatically  shows  past  24  hours  maximum  outdoor 

temperature and humidity record. 

MAX

” 

show on the LCD 

l

 

After  start  up,  the  unit  automatically  shows  past  24  hours  minimum  outdoor 

temperature and humidity record. 

MIN

” show

 on the LCD. 

 

(2)  Recorded  Maximum/Minimum  Outdoor  Temperature  and  Humidity  from 

Start-up/Reset. 

l

 

Press 

MEM

 button (B3) to view the maximum and minimum temperature and 

humidity record from start-up or reset. 

 flash on the LCD. 

l

 

When  viewing  the  memory  record,  hold 

MEM

  button  for  3  seconds  to  clear 

the maximum and minimum record.   

l

 

When viewing the memory record, press 

MEM

 button (B3) again to check the 

corresponded  time  and date for  memory  maximum  and  minimum  temperature 

&  humidity  record.  The  memory  record  value  and  corresponded  time  and  date 

flash. Press 

MEM

 button select to view: 

Time  &  date  for  minimum  temperature  memory  record,  Time  &  date  for 

minimum  humidity  memory  record,  Time  and  date  for  maximum  temperature 

memory record, Time and date for maximum humidity memory record. 

 

(3)

 

Celsius / Fahrenheit 

l

 

P

ress “°C /°F” button (

B8) to select Indoor/Outdoor Temperature in Celsius mode 

or Fahrenheit mode.   

l

 

If  the  temperature  is  out  of  the  measurable  range,  LL.L  (beyond  the  minimum 

temperature) or HH.H (beyond the maximum temperature) will be shown on the 

LCD. 

(4) Humidity 

l

 

The  humidity  measurable  range  is  20%  ~  99%.  If  the  current  humidity 

Reviews: