background image

Click Dome

 ConnexxAir

User Guide

Draft | english | 2016-12-13

Summary of Contents for ConnexxAir

Page 1: ...Click Dome ConnexxAir User Guide Draft english 2016 12 13...

Page 2: ...oop 10 Connecting ConnexxAir 11 Programming with ConnexxAir 13 Wearing ConnexxAir 14 Programming on the table 15 Important safety information 16 Important information 21 Status LEDs 21 Troubleshooting...

Page 3: ...atient s neck and wirelessly connect your patient s hearing instruments to the programming software on the PC No programming cables are necessary Follow these instructions to set up ConnexxAir and to...

Page 4: ...Draft english 2016 12 13 Included in delivery ConnexxAir Charging cradle Neckloop is also the antenna Power plug with different adapters depending on your country USB power cable USB Bluetooth dongle...

Page 5: ...5 Draft english 2016 12 13 Components Power button Status LEDs Pairing button Reset button recessed USB port for firmware updates Battery compartment...

Page 6: ...r country you have to assemble the power plug with an adapter X For US sockets no adapter is required Fold out the plugs left picture X For all other sockets an adapter is required right picture Fold...

Page 7: ...the middle LED is flashing orange Battery is low X Connect the charging cradle with the power plug to a power supply X Carefully push ConnexxAir in the charging cradle ConnexxAir is automatically turn...

Page 8: ...ir out of the charging cradle ConnexxAir is automatically turned on Further information A fully charged ConnexxAir can be used for approximately 10 programming sessions before recharging is required D...

Page 9: ...X Turning on Shortly press the power button The middle LED first shines green then goes off Left and right LED light up shortly X Turning off Press the power button until the middle LED fades off The...

Page 10: ...Further information If the neckloop is not plugged in completely the programming software displays a warning message If the neckloop is disconnected for more than 15 minutes ConnexxAir turns automatic...

Page 11: ...gle for the first time ConnexxAir searches for the dongle it is in pairing mode All three LEDs flash green from left to right X In the software for programming the hearing instruments e g Connexx sele...

Page 12: ...n to the hearing instruments is established ConnexxAir is ready for programming the hearing instruments When left or right LED flash green data are transferred to the respective hearing instrument Fur...

Page 13: ...ng instruments while your patient is wearing them you have to ensure that ConnexxAir is worn correctly Refer to section Wearing ConnexxAir When programming hearing instruments that are lying on the ta...

Page 14: ...n correctly your patient must wear the hearing instruments and ConnexxAir with the neckloop around the neck The neckloop is also the antenna X Unplug one neckloop plug and place the neckloop loosely a...

Page 15: ...Place the hearing instruments along the neckloop refer to the picture X Keep a minimum distance of 3 cm 1 2 inches between the two hearing instruments X Keep a distance of 5 to 10 cm 2 to 4 inches bet...

Page 16: ...s batteries and accessories out of reach of children and mentally disabled persons X If parts have been swallowed consult a physician or hospital immediately NOTICE Your device is sensitive to extreme...

Page 17: ...ir is not compatible with active implants WARNING Interference with implantable devices X The device can be used with all electronic implants that comply with the ANSI AAMI ISO 14117 2012 Electromagne...

Page 18: ...cuit pierce crush or disassemble the rechargeable battery X Prior to return the battery for recycling tape the electrodes to prevent short circuit which may cause the battery to explode X Do not place...

Page 19: ...t the power plug is easily accessible to remove it from power supply if necessary WARNING Risk of electrical shock X Do not use obviously damaged devices and return them to point of sale WARNING Note...

Page 20: ...trangulation X Ensure that the neckloop does not get entangled e g in moving mechanical parts of machines X Use only the delivered neckloop It will automatically detach when entangled X Do not use the...

Page 21: ...lashing slowly once every 3 seconds Programming connection is not established Data transfer between ConnexxAir and hearing instruments is not possible Flashing quickly once per second Programming conn...

Page 22: ...e with ConnexxAir Connection to the dongle cannot be established all three LEDs are flashing green from left to right Ensure that the dongle is plugged and within operating distance Ensure that dongle...

Page 23: ...battery is installed on delivery If the battery deteriorates and it does not store charge as well as before you can replace the battery Spare batteries are available as service parts X Slide the batte...

Page 24: ...ols used in this document Points out a situation that could lead to serious moderate or minor injuries Indicates possible property damage Advice and tips on how to handle your device better Symbols on...

Page 25: ...conditions Operating conditions Temperature 10 to 45 C Relative humidity 5 to 93 During extended periods of transport and storage please observe the following conditions Storage Transport Temperature...

Page 26: ...ng according to local regulations X To avoid environmental pollution do not throw batteries into household trash X Recycle or dispose of batteries according to local regulations or return them to your...

Page 27: ...Devices with the FCC marking comply with the standards of the FCC regarding electromagnetic interference This Class B digital apparatus complies with Canadian ICES 003 This device complies with Part...

Page 28: ...ipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or...

Page 29: ...nglish 2016 12 13 www sivantos com brands Document No 99T Order Item No Master Rev 2016 Sivantos GmbH 2016 Legal Manufacturer Sivantos GmbH Henri Dunant Strasse 100 91058 Erlangen Germany Phone 49 913...