Connect Tech Xtreme/10G User Manual Download Page 1

 

 
 
 
 
 
 
 

Xtreme/10G Managed Ethernet 

Switch/Router 

Users Guide 

 

 

 

 

 

Connect Tech Inc.

 

 

Tel:

 

519-836-1291 

42 Arrow Road

 

 

Toll:

 

800-426-8979 (North America only) 

Guelph, Ontario 

 

Fax:

 

519-836-4878 

N1K 1S6 

 

Email:

 

[email protected]  

www.connecttech.com

         

   

[email protected] 

 

CTIM-00472 Revision 0.04  2017-07-27

 

Summary of Contents for Xtreme/10G

Page 1: ...Users Guide Connect Tech Inc Tel 519 836 1291 42 Arrow Road Toll 800 426 8979 North America only Guelph Ontario Fax 519 836 4878 N1K 1S6 Email sales connecttech com www connecttech com support connecttech com CTIM 00472 Revision 0 04 2017 07 27 ...

Page 2: ...tch Summary Locations 10 Detailed Feature Description 11 Main Board to Board Connector 11 Pinout Table 12 Board to Board Reference Design Package 13 Switch Details 14 DIP Switch Details S1 14 Typical Installation 14 On Board Indicator LED s 14 CLI Management Interface 15 CLI Access via External Serial Port 15 CLI Basics 15 Complete CLI and Protocol Configuration Reference Guide 15 Web Management I...

Page 3: ...Ethernet Switch Router Users Guide www connecttech com Document CTIM 00472 Revision 0 04 Page 3 of 24 Connect Tech Inc 800 426 8979 519 836 1291 Date 2017 07 27 3D Model 23 2D Drawing Top Side 23 2D Drawing Bottom Side 24 ...

Page 4: ...sist you Our support section is available 24 hours a day 7 days a week on our website at www connecttech com sub support support asp See the contact information section below for more information on how to contact us directly Our technical support is always free Contact Information Mail Courier Connect Tech Inc Technical Support 42 Arrow Road Guelph Ontario Canada N1K 1S6 Email Internet sales conn...

Page 5: ... components are available Should the product prove to be irreparable Connect Tech Inc reserves the right to substitute an equivalent product if available or to retract the Warranty if no replacement is available The above warranty is the only warranty authorized by Connect Tech Inc Under no circumstances will Connect Tech Inc be liable in any way for any damages including any lost profits lost sav...

Page 6: ...g circuit boards at a minimum you should touch a grounded metal object to dissipate any static charge that may be present on you Only handling circuit boards in ESD safe areas which may include ESD floor and table mats wrist strap stations and ESD safe lab coats Avoiding handling circuit boards in carpeted areas Try to handle the board by the edges avoiding contact with components Revision History...

Page 7: ...s and 32K MAC table entries Push pop up to 3VLAN tags on ingress and egress RSTP and MSTP support Fully non blocking wire speed switching performance for all frame sizes IPv4 IPv6 unicast and multicast Layer 2 switching with up to 32K groups and 1K port masks IPv4 IPv6 unicast and multicast Layer 3 forwarding routing with reverse path forwarding RPF support IGMPv2 IGMPv3 MLDv1 and MLDv2 support Li...

Page 8: ...4 IPv6 Next hop ARP table entries 2k IP multicast groups 2k 512 Multicast router leg masks 1k ECMPs 16 Management Access Web Interface CLI via RS 232 Software API SMNP Input Voltage 4V to 14V Input Range External Connector Power Consumption 24W Max 14W Idle Dimensions 85mm x 85mm Weight TBD MTBF TBD Operating Temp 40 C to 85 C chipset rated to 125 C thermals Warranty and Support Lifetime Warranty ...

Page 9: ...witch Router Users Guide www connecttech com Document CTIM 00472 Revision 0 04 Page 9 of 24 Connect Tech Inc 800 426 8979 519 836 1291 Date 2017 07 27 Connector Locations Top Side Bottom Side Main Board to Board P1 Config Switch S1 ...

Page 10: ... Page 10 of 24 Connect Tech Inc 800 426 8979 519 836 1291 Date 2017 07 27 Connector Summary Designator Connector Description P1 Main Board to Board Primary Signal and Power Breakout Connector Switch Summary Locations Designator Function Description S1 Config Switch Used to Put Switch in to Manual Reset Mode ...

Page 11: ... 4x 10G for connection to SFP on the carrier board 8x 8G for connection to SFP on the carrier board LED management signal chain SFP detection and control chain LED and SFP management signals chains required specific circuitry on the carrier see the reference design for details Function Primary Signal and Power Breakout Location P1 XDG201 Module Connector Primary Part Manufacturer TE Connectivity P...

Page 12: ...1GC P13 D3_N 1GC P4 D3_N C58 D58 1GC P1 D3_N 1GC P16 D2_P A57 B57 1GC P13 D2_P 1GC P4 D2_P C57 D57 1GC P1 D2_P 1GC P16 D2_N A56 B56 1GC P13 D2_N 1GC P4 D2_N C56 D56 1GC P1 D2_N 1GC P16 D1_P A55 B55 1GC P13 D1_P 1GC P4 D1_P C55 D55 1GC P1 D1_P 1GC P16 D1_N A54 B54 1GC P13 D1_N 1GC P4 D1_N C54 D54 1GC P1 D1_N 1GC P16 D0_P A53 B53 1GC P13 D0_P 1GC P4 D0_P C53 D53 1GC P1 D0_P 1GC P16 D0_N A52 B52 1GC ...

Page 13: ...for the XBG301 breakout board This details how to properly interface to the XDG201 Switch This package contains the following for the XBG301 Breakout Board Altium Designer ECAD Source Files PDF Schematic Files Gerbers Manufacturing Files Bill of Materials Tech Data B2B Pinout Information 3D Models as well for the Switch Module and Heatspreader The Reference Design Package can be downloaded here ht...

Page 14: ...allation 1 Install XHG201 heatplate to XDG201 module 2 Prepare breakout carrier board with 4 x M3 8mm standoffs 3 Ensure breakout carrier board will be supplying module with 12V DC 4 Mate board to board connector from XDG201 module to that of the breakout carrier board 5 Turn power ON to breakout carrier board XDG201 will now boot up On Board Indicator LED s The XDG201 has 2 on board indicator LED...

Page 15: ... will display a list of the available commands Below is a list of common quick CLI commands For a complete CLI reference please see the documents described below Common Task CLI Command Syntax What are the IP addresses used by my switch show ip int br What ports are linked and at what speed show int status What software version is on my switch show ver How do I save my configuration copy running c...

Page 16: ...o your host PC using a standard Cat5e ethernet cable o Setup your host PC s IP address to be on the same subnet as Xtreme 10G 10 10 10 X o Open a web browser and go to the 10 10 10 1 address o Now you should see the login screen and from here you can setup the Xtreme 10G to an IP address on your network Method 2 Changing the Xtreme 10G IP to one on your network via the CLI This method requires hav...

Page 17: ...ocol Configuration reference guide from Microsemi for the VSC7429 device can be downloaded here It will have CLI and Web configuration methods listed The following document AN1115Layer2ProtocolConfigurationGuide Will have the below mentioned copyright notice Copyright 2002 2015 Microsemi Corporation All Rights Reserved Unpublished rights reserved under the copyright laws of the United States of Am...

Page 18: ...h is a COTS breakout board solution for the XDG201 switch This breakout board is also meant to serve as a Reference Design platform for customers to use for their own development purposes CTI provides full Bill of Materials Schematics Layout files and user documentation for the XBG301 embedded carrier in a Reference Design Package The Reference Design Package for this breakout board be downloaded ...

Page 19: ... Managed Ethernet Switch Router Users Guide www connecttech com Document CTIM 00472 Revision 0 04 Page 19 of 24 Connect Tech Inc 800 426 8979 519 836 1291 Date 2017 07 27 XBG301 XDG201 XHG201 Dimensioned Drawing ...

Page 20: ...0G Managed Ethernet Switch Router Users Guide www connecttech com Document CTIM 00472 Revision 0 04 Page 20 of 24 Connect Tech Inc 800 426 8979 519 836 1291 Date 2017 07 27 XBG301 XDG201 XHG201 Assembly Drawing ...

Page 21: ...ximum Operating Junction Temperature of all chipsets 125 C Total Solution TDP 24 Die junction to package case top SoC PHY 3 27 C W Die junction to PCB SoC PHY 6 03 C W Die junction to Ambient SoC PHY 12 14 C W Die junction to moving air 1 m s SoC PHY 9 42 C W XHG201 Conduction Cooled Heatplate The XHG201 is a flat heatplate that can be used to interface the XDG201 to another thermal extraction lay...

Page 22: ...XDG201 Switch Theoretical Maximum Amps Watts Theoretical absolute maximum total draw of all functionality on the board 2 00 24 Below are measurements taken with the XDG201 Switch running in various configurations All measurements below are used with 12V applied to the Input Power Connector Actual Measurements Amps Watts Idle No Links Up 1 17 14 04 1x 1G Link Up 1 20 14 40 24 x 1G Links Up 1 76 21 ...

Page 23: ...tech com Document CTIM 00472 Revision 0 04 Page 23 of 24 Connect Tech Inc 800 426 8979 519 836 1291 Date 2017 07 27 Mechanical Details 3D Model Download Link http www connecttech com ftp 3d_models XDG201_3D_MODEL_v001 zip 2D Drawing Top Side Dimensions in millimeters ...

Page 24: ...itch Router Users Guide www connecttech com Document CTIM 00472 Revision 0 04 Page 24 of 24 Connect Tech Inc 800 426 8979 519 836 1291 Date 2017 07 27 2D Drawing Bottom Side Dimensions in millimeters Location of Pin 1 detailed below ...

Reviews: