background image

Copyright 

© 

2020 

congatec 

AG 

 

      DSTXm10 

       

13/75

Specifications

3.1 

Feature List

Table 1  

Feature Summary

Form Factor

Based on Intel Mini-STX form factor (147 mm by 140 mm)

Part Number

065450

Supported Modules

COM Express™ Type 7 compact and basic form factor

Operating 

Temperature Range

-40°C to 85°C 

Ethernet

Gigabit Ethernet with support for

:

 

-

4x 10 Gb SFP+ (Inphy CS4227) 

 

-

3x 1 Gb RJ45

Board Management 

Controller

ASPEED AST2500

Graphics

VGA from BMC

Back Panel I/O 

Connectors

4x 10 Gbe SFP+ 

3x 1 Gbe RJ45 

1

2x USB 3.1 Gen 2

12 V DC input

Onboard I/O 

Connectors

1x Board to board PCIe x16 connector for add-on cards

Extension Sockets:

 

-

2x M.2 key M, type 2280 (PCIe x4/SATA)

 

-

1x M.2 key B, type 3042 (PCIe x2/USB/I2C) 

2

COM Express Type 7 connectors

2x RS232 UART

1x Mini-Fit power connector

1x Feature connector 

(power button, reset,sleep, watchdog, GPIO, 

serial ports 0-1, SMB/I2C)

1x CPU fan

1x System fan

1x VGA (via the BMC)

1x SOIC8 for flashing external BIOS

IPMI

Baseboard Management Controller

Intelligent Platform Interface 2.0 (IPMI 2.0)

KVM, media redirection

IPMI over LAN

Serial over LAN

Software

AMI Megarc SPX BMC firmware
32 MB serial SPI flash with congatec Embedded BIOS features

Other Features

Buzzer

Thermal and voltage monitoring

CMOS Battery

Boot from external BIOS flash

Optional Features

BMC UART
Status LEDs powered from S0

Summary of Contents for 065450

Page 1: ...Copyright 2020 congatec AG DSTXm10 1 75 COM Express conga STX7 Detailed description of the congatec COM Express Type 7 carrier board User s Guide Revision 1 0...

Page 2: ...2020 congatec AG DSTXm10 2 75 Revision History Revision Date yyyy mm dd Author Changes 0 1 2020 02 12 AEM Preliminary release 1 0 2020 07 24 AEM Added section 6 BMC Configuration and Management Offici...

Page 3: ...special or exemplary damages whether based on tort contract or otherwise arising out of or in connection with this user s guide or any other information contained herein or the use thereof Intended A...

Page 4: ...he congatec COM Express carrier board and possible mating connector Link to connector layout diagram This link icon is located in the top left corner of each page It provides a direct link to the conn...

Page 5: ...at congatec s option and expense Customer will obtain a Return Material Authorization RMA number from congatec AG prior to returning the non conforming product freight prepaid congatec AG will pay for...

Page 6: ...nical support department by email at support congatec com Terminology Term Description BMC Board Management Controller GbE Gigabit Ethernet HDA High Definition Audio IPMI Intelligent Platform Manageme...

Page 7: ...r 34 4 11 SPI Flash Socket 34 4 12 Front Panel Header 35 4 13 Feature Connector 36 5 BMC Overview 38 5 1 Firmware 38 5 2 Features 38 6 BMC Configuration and Management 40 6 1 Before You Begin 40 6 2 E...

Page 8: ...Copyright 2020 congatec AG DSTXm10 8 75 8 2 PC Speaker 72 8 3 Ground Test Points 73 8 4 SM Bus 73 8 5 I2 C Bus 73 8 6 LPC Bus 73 8 7 PWR_OK 74 8 8 Module Type Detection 74 9 Mechanical Dimensions 75...

Page 9: ...ader X39 Pinout Description 24 Table 11 X48 Pinout Description 25 Table 12 X13 Pinout Description 29 Table 13 GbE Pinout Description 30 Table 14 X3 Pinout Description 31 Table 15 X14 Pinout Descriptio...

Page 10: ...of the I O interfaces as deemed necessary The carrier board can therefore provide all the interface connectors required to attach the system to the application specific peripherals This versatility al...

Page 11: ...om In Tool will change indicating there is a link Click on the link to navigate to the area in the document where the component is described Use the mouse icon in the top left hand corner of the desti...

Page 12: ...020 congatec AG DSTXm10 12 75 2 1 4 3 3 2 1 4 KEY ID M KEY ID M KEY ID B 22 00x80 00 SSD M2 CARD 22 00x80 00 SSD M2 CARD SSD M2 CARD 22 00x42 00 6 5 4 3 2 1 2 M22 M23 M20 U47 X41 X40 X42 X13 SW3 SW1 S...

Page 13: ...to board PCIe x16 connector for add on cards Extension Sockets 2x M 2 key M type 2280 PCIe x4 SATA 1x M 2 key B type 3042 PCIe x2 USB I2C 2 COM Express Type 7 connectors 2x RS232 UART 1x Mini Fit powe...

Page 14: ...side 2 mm PCB and 5 4 mm bottom side 3 3 Supply Voltage Power 12 V DC 10 3 4 Environmental Specifications Temperature Operation 0 C to 60 C Storage 40 to 85 C commercial temperature Temperature Operat...

Page 15: ...11 GND FIXED A66 GND B66 WAKE0 A12 GBE0_MDI0 B12 PWRBTN A67 GPI2 B67 WAKE1 2 A13 GBE0_MDI0 B13 SMB_CK A68 PCIE_TX0 B68 PCIE_RX0 A14 GBE0_CTREF B14 SMB_DAT A69 PCIE_TX0 B69 PCIE_RX0 A15 SUS_S3 B15 SMB_...

Page 16: ...1 A95 SPI_MOSI B95 NCSI_TXD1 A41 GND FIXED B41 GND FIXED A96 TPM_PP 2 B96 NCSI_TXD0 A42 USB2 B42 USB3 A97 TYPE10 B97 SPI_CS A43 USB2 B43 USB3 A98 SER0_TX B98 NCSI_ARB_IN 2 A44 USB_2_3_OC 2 B44 USB_0_1...

Page 17: ...IE_RX21 D68 PCIE_TX21 C14 GND D14 GND C69 PCIE_RX21 D69 PCIE_TX21 C15 10G_PHY_MDC_SCL3 D15 10G_PHY_MDIO_SDA3 C70 GND FIXED D70 GND FIXED C16 10G_PHY_MDC_SCL2 D16 10G_PHY_MDIO_SDA2 C71 PCIE_RX22 D71 PC...

Page 18: ...FIXED C96 GND D96 GND C42 10G_KR_RX1 D42 10G_KR_TX1 C97 RSVD D97 RSVD C43 10G_KR_RX1 D43 10G_KR_TX1 C98 PCIE_RX30 D98 PCIE_TX30 C44 GND D44 GND C99 PCIE_RX30 D99 PCIE_TX30 C45 10G_PHY_MDC_SCL1 D45 10...

Page 19: ...out Description Pin Function Inner Shell 12 V 10 Outer Shell GND Connector Type X43 DC power jack 7 4 x 5 1 mm diameter 4 1 2 Mini Fit 4 Pin Connector The conga STX7 provides an internal 4 pin Mini Fi...

Page 20: ...y replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Connector Type X31 X49 2 54mm 1 x 2 pin...

Page 21: ...king Link without activity Link established activity detected LAN 2 1 GbE Left Orange Green On 100 Mb or 1 Gb speed Right Green On steady blicking Link without activity Link established activity detec...

Page 22: ..._Rx7 30 N C 31 PCIe_Rx7 32 N C 33 GND 34 N C 35 PCIe_Tx7 36 N C 37 PCIe_Tx7 38 DEVSLP 39 GND 40 N C 41 PCIe_Rx6 42 N C 43 PCIe_Rx6 44 N C 45 GND 46 N C 47 PCIe_Tx6 48 N C 49 PCIe_Tx6 50 PERST 51 GND 5...

Page 23: ..._Rx11 PCIe_Rx3 6 N C 7 PCIe_Rx11 PCIe_Rx3 8 N C 9 GND 10 M2_SATA_LED 11 PCIe_Tx11 PCIe_Tx3 12 3 3V 13 PCIe_Tx11 PCIe_Tx3 14 3 3V 15 GND 16 3 3V 17 PCIe_Rx10 PCIe_Rx2 18 3 3V 19 PCIe_Rx10 PCIe_Rx2 20 N...

Page 24: ...62 63 64 65 66 67 N C 68 N C 69 PEDET 70 3 3V 71 GND 72 3 3V 73 GND 74 3 3V 75 GND Connector Type X40 X41 Standard PCIe M 2 key M socket 4 2 2 1 HDD LED Pin Header The yellow LED D30 on the conga STX...

Page 25: ...VSB 9 CLKREQ 10 CB_RESET 11 3 3 V 12 3 3 V 13 3 3 V 14 GND 15 3 3 V 16 GND 17 GND 18 PCIe0_CLK 19 SUS_S3 20 PCIe0_CLK 21 GND 22 GND 23 GND 24 GND 25 PCIe_Tx16 26 PCIe_Rx16 27 PCIe_Tx16 28 PCIe_Rx16 2...

Page 26: ...e_Tx22 76 PCIe_Rx22 77 GND 78 GND 79 GND 80 GND 81 PCIe_Tx23 82 PCIe_Rx23 83 PCIe_Tx23 84 PCIe_Rx23 85 GND 86 GND 87 GND 88 GND 89 PCIe_Tx24 90 PCIe_Rx24 91 PCIe_Tx24 92 PCIe_Rx24 93 GND 94 GND 95 GND...

Page 27: ...PCIe_Rx29 131 PCIe_Tx29 132 PCIe_Rx29 133 GND 134 GND 135 GND 136 GND 137 PCIe_Tx30 138 PCIe_Rx30 139 PCIe_Tx30 140 PCIe_Rx30 141 GND 142 GND 143 GND 144 GND 145 PCIe_Tx31 146 PCIe_Rx31 147 PCIe_Tx31...

Page 28: ...STX7 PCIe lanes are routed as shown below PCIe x16 Board to Board Connector X48 M 2 Key M X40 M 2 Key B X42 M 2 Key M X41 Row A B Row C D VGA X13 RJ45 X21 PCIe 4 LPC NCSI USB Port 3 SER0 PCIe 0 3 PCI...

Page 29: ...en resolutions WXGA 1280 x 800 32 16 bpp 60 Hz WXGA 1440 x 900 32 16 bpp 60 Hz WSXGA 1680 x 1050 32 16 bpp 60 Hz FullHD 1920 x 1080p 32 16 bpp 60 Hz VESA compliant DDC interfaces for the display monit...

Page 30: ...erface from the conga STX7 on X22 lower slot and a BMC management interface on X21 The BMC management interface does not support network connectivity The status LEDS on X22 lower slot are powered from...

Page 31: ...Y on the carrier board and the MAC on the COM Express module Table 14 X3 Pinout Description Pin Signal 1 LAN1_MDC_SCL 2 LAN1_MDIO_SDA 3 LAN3_MDC_SCL 4 LAN3_MDIO_SDA Table 15 X14 Pinout Description Pin...

Page 32: ...s two RS 232 compliant serial ports via pin headers X25 and X26 Both ports are sourced from an LPC to UART transceiver by default With an assembly option the UART signals on pin header X25 can be sour...

Page 33: ...ault 2 and 4 OFF 1 and 3 OFF BMC Debug UART to pin header X25 assembly option 2 and 4 ON Connector Type X25 X26 2 54 mm 2 x 5 pin header SW3 DIP switch 4 9 2 General Purpose Serial Ports The conga STX...

Page 34: ...lies with 4 Wire Pulse PWM Controlled Fans Specification Revision 1 3 2 FAN_TACHOIN fan output shall provide two pulses per revolution 3 The fan must pull up the FAN_CTRL signal to high logic level Co...

Page 35: ...odule firmware but load management data from carrier SPI Connector Type U47 SPI flash SOIC8 socket M19 DIP switch 4 12 Front Panel Header The conga STX7 provides the following front panel headers X50...

Page 36: ...a 12 SMB_CLK OD 3 3 V standby SM bus clock output up to 100 kHz 13 SMB_ALERT Input 3 3 V standby SM bus alert system wake or SMI active low 14 GND Ground 15 Tx_CGBC Output 3 3 V standby UART transmit...

Page 37: ...active low 38 THRM Input 3 3 V External thermal event active low 39 WDOUT Output 3 3 V Watchdog output event module 40 N C Not connected 41 I2C_DAT I OD 3 3 V standby I2C data bus from module general...

Page 38: ...es that all the BMC management tasks defined by IPMI 2 0 as well as video redirection and remote monitoring using SoL or KVM over LAN are performed 5 2 Features Some of the features supported by the f...

Page 39: ...de SSH based Serial Over LAN SoL 1 Power control of the server Complete command support Dynamic target discovery Firmware update Role based authentication and authorization IPMI chassis boot device ma...

Page 40: ...er installation 3 Insert the LAN cable plug to the BMC LAN port X21 or the 10 GbE 2 cable to X15 or X17 Note 1 The BMC configuration examples in this document were tested on Ubuntu 18 04 2 For remote...

Page 41: ...he BMC remotely you need to configure the IP address of LAN channel 2 for DHCP or static addressing You can do this in two ways using the BIOS setup menu using the IPMI commands in Linux 6 3 1 Configu...

Page 42: ...Lan channel 2 select Current Configuration Address Source 6 Press Enter and then select Static or Dynamic Address Note For static addressing configure the IP address subnet mask and gateway address F...

Page 43: ...75 7 Navigate to Save Exit 8 Select Save Changes and Exit and then press Enter to restart the system with new LAN settings 9 During POST press DELETE to enter the BIOS setup menu 10 Follow steps 2 4...

Page 44: ...hout connecting a network cable to the BMC LAN For more information see section 7 1 2 Local Access Using Ipmitool Linux 2 Set the network addressing of channel 2 to DHCP or static The example below se...

Page 45: ...ing the BIOS Setup Menu or the Linux ipmitool tool 7 1 1 Local Access Using BIOS Setup Menu 1 Plug one end of a LAN cable into the conga STX7 BMC LAN port Plug the other end into a Windows or Linux la...

Page 46: ...age For instructions on how to log in see section 7 2 1 2 Logging In 7 1 2 Local Access Using Ipmitool Linux The ipmitool is an open source utility to monitor configure and manage devices that support...

Page 47: ...the sensor readings and status summarized list of all sensors and their status congatec congatec desktop sudo ipmitool sdr list comprehensive list of all sensors and their status congatec congatec des...

Page 48: ...ol sel get 1 7 1 2 4 LAN Configuration Parameters With the ipmitool you can configure and view the IP network settings configure the channel s network assignment as dynamic or static Dynamic network a...

Page 49: ...et 2 netmask 255 255 0 0 Setting LAN Subnet Mask to 255 255 0 0 congatec congatec desktop sudo ipmitool lan set 2 defgw ipaddr 10 11 0 254 Setting LAN Default Gateway IP to 10 11 0 254 view network co...

Page 50: ...c desktop sudo ipmitool chassis power on Chassis Power Control Up On reset the conga STX7 server congatec congatec desktop sudo ipmitool chassis power cycle Chassis Power Control Cycle shut down the o...

Page 51: ...based MegaRAC SP X GUI to remotely monitor and configure the server 7 2 1 1 Supported Browsers The MegeRAC SP X GUI supports the following browsers Internet Explorer Windows Edge Firefox Safari Opera...

Page 52: ...Copyright 2020 congatec AG DSTXm10 52 75 3 When the security warning appears click Advanced to continue 4 Click Accept the Risk and Continue...

Page 53: ...G DSTXm10 53 75 5 When the Login page appears enter the default username and password Username admin Password admin Note For security reasons change the username and password after the first login 6 C...

Page 54: ...tion FRU Information Displays the BMC Field Replaceable Unit file information Note The conga STX7 does not feature FRUs Logs Reports Shows event logs and reports of the IPMI system audit and video Set...

Page 55: ...out of the current MegaRAC session 7 2 1 3 KVM Remote Control Operation The remote control allows you to do the following control the conga STX7 operating system remotely using KVM over IP redirect lo...

Page 56: ...Copyright 2020 congatec AG DSTXm10 56 75 2 Click H5Viewer or JViewer button to access the conga STX7 screen Note JViewer requires the installation of Java Runtime Environment plugin...

Page 57: ...57 75 Redirect Local Media 1 At the upper right hand corner click Browse File to open the file browser 2 Navigate to a bootable image 3 Select the image and click open 4 Click Start Media at the upper...

Page 58: ...Copyright 2020 congatec AG DSTXm10 58 75 5 Click Power and then Power Cycle Server to restart the system 6 When the Power Cycle dialog box appears click OK to restart...

Page 59: ...Copyright 2020 congatec AG DSTXm10 59 75 7 When the startup screen appears press F11 to show the boot options 8 Select UEFI AMI Virtual CDROM 0 1 00 with the UP ARROW key...

Page 60: ...Copyright 2020 congatec AG DSTXm10 60 75 9 Press any key to start the installation...

Page 61: ...I open H 10 11 9 149 U admin lan set 2 netmask 255 255 0 0 Configures channel 2 s netmask sudo ipmitool I open H 10 11 9 149 U admin lan set 2 defgw 10 11 0 254 Configures channel 2 s default gateway...

Page 62: ...r to access monitor and manage a server remotely via console redirection 7 2 3 1 SoL Configuration Follow the steps below to configure the conga STX7 for Serial over LAN 1 Turn on the system 2 During...

Page 63: ...Copyright 2020 congatec AG DSTXm10 63 75 iii Enable Serial Port d Scroll down to Serial Port Console Redirection...

Page 64: ...Xm10 64 75 i Press Enter to display all conga STX7 COM ports ii Scroll down to Aspeed COM Port 0 and select Console Redirection iii Press Enter and enable Console Redirection iv Select Console Redirec...

Page 65: ...opyright 2020 congatec AG DSTXm10 65 75 v Configure the console redirection with the settings below vi Navigate to Save Exit vii Select Save Changes and Exit and then press Enter to restart the system...

Page 66: ...for accessing and managing the BMC in Windows and in Linux 1 Download the ipmiView installer from the Supermicro website at www supermicro com and install it 2 Double click the ipmiView utility to ope...

Page 67: ...Copyright 2020 congatec AG DSTXm10 67 75 5 Click Start to discover the BMC s IP address 6 Highlight the discovered IP address and then click Save...

Page 68: ...he IPMI Device Discovering window 8 On the left bar under IPMI Domain double click the saved IP address to open the login page 9 Enter the login details Login ID admin Password admin Note For security...

Page 69: ...Copyright 2020 congatec AG DSTXm10 69 75 10 Click Login to connect to the BMC 11 Click Text Console tab at the bottom of the window and then click Start...

Page 70: ...0 70 75 12 Click IPMI Device tab at the bottom of the window to select chassis power control option 13 Click Power Cycle to restart the system 14 Click Yes to confirm the request and then click Text C...

Page 71: ...Copyright 2020 congatec AG DSTXm10 71 75 15 Press DELETE or ESC when you see press DEL or ESC to enter the BIOS setup menu 16 Use LEFT ARROW and RIGHT ARROW keys to navigate the BIOS setup menu...

Page 72: ...an ATX power supply the COM Express module starts after the power on button M22 is pressed 8 1 2 Reset The COM Express module and all connected components will perform a hard reset when this button is...

Page 73: ...SMB are powered by the 3 3 V main power 8 5 I2 C Bus The I C signals are available in different locations on the conga STX7 including the feature connector X32 described in section 4 13 Feature Connec...

Page 74: ...E10 are either left open NC strapped to ground GND or connected to 12 V by the module to encode the pinout type according to the following table For more information refer to the COM Express Specifica...

Page 75: ...G DSTXm10 75 75 9 Mechanical Dimensions X18 X20 X15 X17 X21 X43 X22 X44 X36 X38 M19 2 1 X3 X1 X2 M7 M12 M11 X19 X16 D10 D47 D13 D48 D4 D45 D7 D46 M6 X26 X25 M5 X51 X52 X50 X39 D30 X49 X31 X32 D1 293 3...

Reviews: