System Resources
9.1
I/O Address Assignment
The I/O address assignment of the conga-TCA3 module is functionally identical with a standard PC/AT. The BIOS assigns PCI and PCI Express
I/O resources from FFF0h downwards. Non PnP/PCI/PCI Express compliant devices must not consume I/O resources in that area.
9.1.1
LPC Bus
On the conga-TCA3, the Platform Controller Hub (PCH) acts as the subtractive decoding agent. All I/O cycles that are not positively decoded
are forwarded to the PCH and the LPC Bus. Some fixed I/O space ranges seen by the processor are:
Device
IO Address
8259 Master
20h-21h, 24h-25h, 28h-29h, 2Ch-2Dh, 30h-31h, 34h-35h, 38h-39h, 3Ch-3Dh
8254s
40h-43h, 50h-53h
Ps2 Control
60h, 64h
NMI Controller
61h, 63h, 65h, 67h
RTC
70h-77h
Port 80h
80h-83h
Init Register
92h
8259 Master
A0h- A1h, A4h-A5h, A8h-A9h, Ach-ADh, B0h-B1h, B4h-B5h, B8h-B9h, Bch-BDh, 4D0h-4D1h
PCU UART
3F8h-3FFh
Reset Control
CF9h
Active Power Management
B2h-B3h
Some of these ranges are used by a Super I/O if implemented on the carrier board or are occupied by the COM Express on-module UARTs if
these are enabled in the setup. If you require additional LPC Bus resources other than those mentioned above, or more information about this