62
5.7
MOUNTING THE WATER SOFTENER WITHOUT
BYPASS VALVE
/
Firstly flush the pipe with the newly installed built-in rotary flange. The built-in rotary flange is still
closed by the black assembly cover.
/
Then shut off the water again (at the main water tap or shut-off valve) and remove the assembly cover
of the built-in rotary flange.
The connection flange of the water softener is covered by a white protector cap. This protector cap is se-
cured by four cylinder screws M6×100.
/
Loosen all four cylinder screws M6×100, but don’t remove them (bayonet fixture).
/
Remove the white protector cap.
The section of the profiled flange gasket must point towards the built-in rotary flange (see fig. 3). Failure
to observe this can lead to leaks and water escaping. This can in turn cause water damage to the house and
its installations.
/
Lift up the water softener and swivel it through approx. 30° in an anti-clockwise direction.
/
Position it on the built-in rotary flange so that the screw heads pass through the bayonet fixing drill
holes (see fig. 5 I).
/
Swivel the softener through approx. 30° back in a clockwise direction (see fig. 5 II).
/
Tightly fasten the four cylinder screws M6×100.
After assembling the water softener unscrew the wall support so far that it rests against the water soften-
er casing and the water softener hangs vertically to the wall.
Do not grasp into the connection flange of the device after removing the white
protector cap (crush hazard)!
Select the torque (approx. 4 Nm) so that the gasket closes and the water softener
is not damaged or strained!
Fig. 5: Mounting the water softener
I
II
Summary of Contents for CLEAR SOFT TWIN
Page 43: ...43 10 6 2 ELEKTRONISCHE STEUERUNG Abb 19 Elektronische Steuerung mit St rmelderelais...
Page 44: ...44 11 ERSATZTEILE Abb 20 Ersatzteile CLEAR SOFT TWIN A B C D E E D H H G F J F B...
Page 89: ...89 10 6 2 ELECTRONIC CONTROL Fig 19 Electronic control with fault indication relay...
Page 90: ...90 11 SPARE PARTS Fig 20 Spare parts CLEAR SOFT TWIN A B C D E E D H H G F J F B...
Page 136: ...136 11 CZ CI ZAMIENNE Rys 20 Cz ci zamienne CLEAR SOFT TWIN A B C D E E D H H G F J F B...