1. GENERAL INFORMATION

The following instructions will help you achieve a satisfactory installation of your Cone Drive Series B 

unit, ensuring the best possible conditions for a long and trouble free operation.
All units are tested and checked prior to shipment, a great deal of care is taken in packing and 

shipping arrangements to ensure that the unit arrives at the customer in the approved condition.
Optimum performance is best achieved by a process of gradual load increments, up to the full value, 

over the first 50 hours or so of their working life.  During these early stages of running, sensible 

precautions should be taken to avoid overloads.
The gear unit operating temperature may be higher during this period of run-in.  A progressive 

reduction in temperature may occur over many hours until the unit has reached its highest efficiency.

2. MOUNTING OF COMPONENTS TO EITHER THE UNIT INPUT OR OUTPUT SHAFT

  

Shaft dimensions and tolerances are on page 13 of Series B Catalog.

-

Items (such as gears, sprockets, couplings etc) should not be hammered onto these shafts

since this would damage the shaft support bearings.

-

The item should be pushed onto the shaft using hydraulic or hand press with the shaft sup-

ported at the opposite end.

3. WEATHER PROTECTION OF UNIT

All Series B units are provided with protection against normal weather conditions.  Where units are 

to operate in extreme conditions, or where they are to stand for long periods without running, e.g. 

during plant construction, we should be notified when ordering so that arrangements for adequate 

protection can be made.

4. INSTALLATION

 

4.1

 

MOTORIZED AND REDUCERS 

All sizes are factory filled with a high quality synthetic lubricant.  They are ‘Lubricated for Life’ 

and require no routine maintenance in service.

  

4.2

 

MOUNTING TO CUSTOMER EQUIPMENT

Mounting the gearhead flange facing or feet to the customer equipment use screws 

to ISO grade 8.8 minimum. 

Torque tighten to:

   

4.3

 

MOTOR CONNECTIONS TO MAINS

Connection of the electric motor to the mains supply should be made by a qualified person.

The current rating of the motor will be identified on the motor plate, and correct sizing of the 

           cables to electrical regulations is essential.

Screw Size

Tightening Torque

Tightening Torque

M6

88 lb-ins

7.3 lb-ft

M8

220 lb-ins

18.3 lb-ft

M10

450 lb-ins

37.5 lb-ft

M12

750 lb-ins

62.5 lb-ft

M16

1770 lb-ins

147.5 lb-ft

M20

3100 lb-ins

258.3 lb-ft

M24

5400 lb-ins

450.0 lb-ft