Sales: 1-888-994-2663
Sales Fax: 1-888-907-2663
Traverse City, MI. 49685
Series B
240 E. 12th Street, P. O. Box 272, Traverse City MI 49685-0272 USA
www.Conedrive.com
1. GENERAL INFORMATION
The following instructions will help you achieve a satisfactory installation of your Cone Drive Series B
unit, ensuring the best possible conditions for a long and trouble free operation.
All units are tested and checked prior to shipment, a great deal of care is taken in packing and
shipping arrangements to ensure that the unit arrives at the customer in the approved condition.
Optimum performance is best achieved by a process of gradual load increments, up to the full value,
over the first 50 hours or so of their working life. During these early stages of running, sensible
precautions should be taken to avoid overloads.
The gear unit operating temperature may be higher during this period of run-in. A progressive
reduction in temperature may occur over many hours until the unit has reached its highest efficiency.
2. MOUNTING OF COMPONENTS TO EITHER THE UNIT INPUT OR OUTPUT SHAFT
Shaft dimensions and tolerances are on page 13 of Series B Catalog.
-
Items (such as gears, sprockets, couplings etc) should not be hammered onto these shafts
since this would damage the shaft support bearings.
-
The item should be pushed onto the shaft using hydraulic or hand press with the shaft sup-
ported at the opposite end.
3. WEATHER PROTECTION OF UNIT
All Series B units are provided with protection against normal weather conditions. Where units are
to operate in extreme conditions, or where they are to stand for long periods without running, e.g.
during plant construction, we should be notified when ordering so that arrangements for adequate
protection can be made.
4. INSTALLATION
4.1
MOTORIZED AND REDUCERS
All sizes are factory filled with a high quality synthetic lubricant. They are ‘Lubricated for Life’
and require no routine maintenance in service.
4.2
MOUNTING TO CUSTOMER EQUIPMENT
Mounting the gearhead flange facing or feet to the customer equipment use screws
to ISO grade 8.8 minimum.
Torque tighten to:
4.3
MOTOR CONNECTIONS TO MAINS
Connection of the electric motor to the mains supply should be made by a qualified person.
The current rating of the motor will be identified on the motor plate, and correct sizing of the
cables to electrical regulations is essential.
Screw Size
Tightening Torque
Tightening Torque
M6
88 lb-ins
7.3 lb-ft
M8
220 lb-ins
18.3 lb-ft
M10
450 lb-ins
37.5 lb-ft
M12
750 lb-ins
62.5 lb-ft
M16
1770 lb-ins
147.5 lb-ft
M20
3100 lb-ins
258.3 lb-ft
M24
5400 lb-ins
450.0 lb-ft
Installation & Maintenance