Installation Instructions
Positioning module
Conductor rail program 0832, C-rail,
Console, ProShell
MV0800-0015a-EN
www.conductix.com
translated document
Page 5 of 23
2.2
Installation
2.2.1
Add-on variants
The positioning band profile is mounted at one of the positions provided, depending on the system specifications:
Band holder
Installation variant P0
(top)
Installation variant P0
(bottom)
Installation variant P7
08-H016-0257
08-H016-0258
—
—
08-H016-0259
—
The distance between the band holders should be between 500 and 1000 mm. The band holders should be positioned in such a way
that they do not move during operation. Two installation variants are possible:
Inserting/clipping the positioning band profile into the preassembled band holders
Mounting the band holders with positioning band profile already inserted/clipped