6.3.2.2
Making a notch for the PE
plus
rail
Required tools:
Notching tool (Order No.: 081094) or side cutter for finishing the ends of the PE
plus
rail
Drill Ø 5 mm
NOTE!
The PE
plus
rail has a plastic bar in the insulating profile!
→
A notch, i.e., the removal of the plastic bar, is required in order to be able to mount the connector
(see Section 6.3.3.2) or the end cap (see Section 6.3.3.8) on the PE
plus
rail later.
→
If the notch was sawed away when cutting to length (see Fig. 22), this must be re-made with the notching tool or a side cutter
(see Fig. 23).
→
Make a notch with the notching tool:
→
Slide the insulating profile approx. 30 cm from the conductor bar.
→
Place the notching tool on a firm mounting surface (e.g., a table) and push the insulating profile into the notching tool up
to the stopper.
→
Press the notching tool handle down.
→
After the notch has been made, remove the insulating profile from the notching tool and reinsert the conductor bar back
into the insulating profile.
Fig. 22: PE
plus
rail without notching (with plastic bar)
Fig. 23: PE
plus
rail with notching (without plastic bar)
Use the QR code (“click” or “scan”), to watch our animation
Cutting Phase Rail and PE
plus
Rail, Notching for PE
plus
Rail.
A
A
A-A
A
A
A-A
1.
B
B
B-B
2.
B
B
B-B