Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 23 of 82
3
Technical Specifications
3.1
General Information
Designation
Value, unit
System length (without segmentation)
500 m
Profile length
5000 mm
External profile dimensions (width x height)
50 mm x 56 mm
Power supply:
ProfiDAT
®
transceiver
ProfiDAT
®
infeed cabinet
24 V DC*
120–500 V AC / 50–60 Hz
Maximum data transmission rate
100 Mbit/s
Maximum travel speed of the mobile transceiver
(connection trolley)
5 m/s
Interface
Ethernet (RJ45 as standard)
System service life (except wear parts and
electrical components)
10 years
* Deviations may occur, see the manufacturer’s documentation (chapter 11.2 “Other applicable Documents”)
3.2
Interfaces
3.2.1
Electrical
The interfaces to the customer system are:
Data interface
Power supply/control voltage
PE
Data interface:
ProfiDAT Ethernet, RJ45 connection.
The customer has to connect the ProfiDAT
®
system with its own system at both ends of the ProfiDAT
®
system with a RJ45 connector
or an optional LC (fiber-optic) connector. The interface is located on both the mobile and the stationary transceivers.
The customer system must provide the data using the Ethernet protocol. If the customer control system is not Ethernet capable, the
appropriate conversions must be made.
PE interface:
The interface for the customer's grounding cable is located at the PE rail connector (see chapter 4.3.1). At the flap (M10 drilled hole),
the PE cable must be connected according to the applicable standards.