3.3
Operating conditions
Designation
Value
Notes
Temperature range
-5 °C to +60 °C
In temperatures of 0 °C and below, the
max. relative humidity must not exceed
30%.
Max. relative humidity
85 %
See above
Max. operating temperature
difference
40 K
Installation situation/environment
Indoors
No condensation, no direct UV radiation
(solar radiation)
Protection class
IP2X
IP4X
If the conductor rail is fitted in the
direction of the Z-axis (see Fig. 3) and the
current collector accesses it from the side
or from below (DIN EN 60204-1).
MASL
≤ 1000 m
Above mean sea level (DIN EN 60204-1).
3.3.1
Unsuitable environmental conditions
The conductor rail is not suitable for and
must not be installed and operated
under the following environmental conditions:
In environments containing chemical substances or gases that can potentially permanently damage the conductor rail's
materials (corrosion) or drastically impact on the insulation
In ambient air that contains solvent vapours or aromatic compounds
In ambient air that contains flammable or explosive gases or dusts
In dusty environments
Outside closed rooms
In environments with relative humidity of more than 85%
In close proximity to splashing water
In environments that require a higher protection class than IP 2X
WARNING!
Faults due to incorrect operating conditions!
If the operating conditions change or are no longer within the specified range, the conductor rails can
malfunction due to short circuits, premature aging and damage to electrical and mechanical
components.
→
The conductor rail must be switched off if the operating conditions are no longer within the
permissible range described above.
→
The conductor rail must be switched off if it gets wet or is dirty. Dry or clean as specified, see
section 12.3
→
Take the relevant measures required to restore the operating conditions to suitable conditions.