Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 117 of 123
Index Parameter
Description
54
Overload Container 1
Number of Container 1 overloads
55
Overload Container 2
Number of Container 2 overloads
56
Overload Container 1+2
Number of Container 1+2 overloads
57
Status 0
For the Status 0 definition (see chapter 7).
58
Status 1
For the Status 1 definition (see chapter 7).
59
Status 2
For the Status 2 definition (see chapter 7).
60
Status 3
For the Status 3 definition (see chapter 7).
61
Alarm 1
For the Alarm 1 definition (see chapter 7).
62
Alarm 2
For the Alarm 2 definition (see chapter 7).
63
Alarm 3
For the Alarm 3 definition (see chapter 7).
64
Alarm 4
For the Alarm 4 definition (see chapter 7).
65
Alarm 5
For the Alarm 5 definition (see chapter 7).
6.4.2
Serial communication protocol
The serial communication is only available for the singe-lift mode.
Communication option 1
Index Parameter
Description
0
Weight Container
Stabilized total container weight [kg]
1
Weight Twislock 4
Weight on Twistlock 4 [Ton]
2
Weight Twislock 3
Weight on Twistlock 3 [Ton]
3
Weight Twislock 1
Weight on Twistlock 1 [Ton]
4
Weight Twislock 2
Weight on Twistlock 2 [Ton]
5
Eccentricity X (length) container
Eccentricity in x direction container [%]
6
Eccentricity Y (width) container
Eccentricity in x direction container [%]
Communication option 2
Index Parameter
Description
0
Weight Container
Stabilised total container weight [kg]
1
Date
Date of measurement [dd.mm.yyyy]
2
Time
Time of measurement [hh.mm.ss]
Communication option 3
Index Parameter
Description
0
Crane number
Number of the crane (optional)
4
Weight Container
Stabilized total container weight [Ton]
5
Eccentricity X (length) container
Eccentricity in x direction [%]
6
Eccentricity Y (width) container
Eccentricity in y direction [%]
7
Weight Twistlock 1
Weight on Twistlock 1 [Ton]
8
Weight Twistlock 2
Weight on Twistlock 2 [Ton]
9
Weight Twistlock 3
Weight on Twistlock 3 [Ton]