Operating Instructions
750 W 27 V pickup
CQF 04/2 + Interface M12
BAL9100-0145a-EN
www.conductix.com
translated document
Page 35 of 40
10.4
Reset
If the interface is used:
If the interface is used, a device reset can simply be done by switching off (opening contacts 1 - 4) and then switching back on
(release, closing contacts 1 - 4).
If the interface is not used:
If the interface is not used, a reset of the device can be carried out via the pilot contacts, that is, disconnecting and reinserting the
connection cable of the DC power output.
NOTE!
The pilot contacts are not intended as on-off switches; therefore disconnecting them under load
should be avoided. See chapter 7.4.3.
In all cases:
If the device departs from the position tolerances described in chapter 8.3 or it is overloaded with increased horizontal/vertical offset,
an automatic reset occurs. The device will then automatically restart, provided contacts 1 - 4 are closed or the release signal is
present.
NOTE!
Removing the device from the magnetic field of the primary track or turning off the primary track will also
reset the device.