CONDTROL Digi Staff User Manual Download Page 1

Congratulations on your purchase of digital staff Digi Staff 

CONDTROL.

Safety instructions can be found in the end of this user manual 

and should be carefully read before you use the device for the 

first time.

SAFETY REGULATIONS

Attention! 

This user manual is an essential part of this product.

The user manual should be read carefully before you use the 

product for the first time. If the product is given to someone for 

temporary use, be sure to enclose user manual to it.

- Do not misuse the product 

- Store the product beyond reach of children and unauthorized 

people.  

- It is prohibited to disassemble or repair the product yourself. 

Entrust product repair to qualified personnel and use original 

spare parts only.

- Do not use the product in explosive environment, close to 

flammable materials.

- Avoid heating the batteries to avoid the risk of explosion and 

electrolyte leakage. In case of liquid contact with skin, wash it 

immediately with soap and water. In case of contact with eyes, 

flush with clean water during 10 minutes and consult the doctor.

FUNCTIONS/APPLICATIONS

Digital staff Digi Staff CONDTROL is an 

easy-to-use electronic length measuring 

instrument for professional users.

Just put it in required position, pull out the 

sections and take measurements. Readings 

will appear on digital display. 

When using with rotary laser, it can 

automatically calculate the height difference 

relative to defined reference points and 

show how much to dig or fill up the ground.

The hold button allows to keep measurement 

result on the display. Measured values can 

be stored in memory.

1 - Section fixing screws

2 - Display

3 - Keypad

4 - Bubble level

5 - Battery compartment

6 - Support pole ( 10cm)

Keypad

- display measured value on LCD/delete measured 

value and continue measuring

 - set a starting point at certain measurement

- save measurement result

- save measurement result

- Select measuring unit: inches, feet and inches, 

fractions, decimals, and centimeters.

- Remove/add support pole

TECHNICAL SPECIFICATIONS

Working height 

1.30…3.00 m

Accuracy 

±1mm

Battery life 

250 hours

Power 

4 X AA 1.5V (alkaline)

Operating temperature

-10°С …50°С 

Storage temperature

-10°С …50°С 

Dimensions

40  X 1300 X 75mm

Weight 

1.652 kg

DELIVERY PACKAGE

Digital staff – 1 pc

Batteries (1.5V AA alkaline) – 4 pcs

User manual – 1 pc.

BEFORE START OPERATION

Insert/replace batteries

Remove the battery cover. Insert the batteries, observing correct 

polarity. Put the battery cover back. Replace batteries as soon as 
the symbol            appears on the display. All batteries must be of 

the same brand, with the same charge level. Remove the batteries 

from the device if it’s not used for a long time to avoid corrosion 

and battery discharge. All batteries must be replaced at the same 

time. 

Switch on/off

Switch on: the staff will switch on automatically as soon as the user 

pulls out its section/s.

Switch off: the staff will switch off automatically in 5 min after the 

last operation.

Measuring units

Press and hold the button                during 1 second to select 

measuring unit: inches, feet and inches, fractions, decimals, and 

centimeters.

Support pole

Support pole (10 cm) length is detachable. Support pole protects the staff from shock when you put it on the ground. It also makes it 

possible to set up the staff on watery ground. The smallest height of SD-300 is 130 cm, including 10cm support pole.

If the support pole is removed, short press the button                       . 

Symbol                                 appears on the display. Total height 120 cm is set.

If the support pole is attached, short press the button    
again.  Symbol                                appears on the display. The total height 130 cm is set.

OPERATION

1) Observing the readings on the bubble level, set the staff in vertical position.

2) Extend the staff to the measuring height and fix it by tightening the section fixing screw/s.

3) Press and hold the button                                 for 1 second until zero symbol appears on the display and the displayed value is 0.0.

4) Short press the button                  . Current measurement is flashing on the display. The measurement will be fixed on the screen.

5) Short press the button                again to start new measurement.

 (minus) value: the user needs to fill the ground as the amount of measured value. 

+

 (plus) value: the user needs to cut the ground as the amount of measured value.

6) If needed, unwind the section fixing screw and set a new height of the staff and repeat actions in points 1-4.

7) To cancel zero point press and hold the button                  for 1 second and the staff will go back to standard measurement.

8) Press and hold the button                         or                      for 1 second to save measurement result in memory. Symbol 

M1

 or 

M2

 will appear 

on LCD.
9) Short press the button                      or                         to recall restored measurements.

10) Move the staff up or down; restored measurement will disappears from the display.

CARE AND MAINTENANCE
Attention! This device is a precision instrument and requires careful handling. Maintenance of the following recommendations will 

extend the life of the device:

- Protect the device from bumps, falling and intense vibration; do not allow moisture, dust and foreign objects get inside the device. 

- If liquids get inside the device, first remove the batteries, then contact a service center.

- Do not store and use the device in increased humidity conditions. 

- Do not store the product in rooms where temperature is below -10°С.  After storage in low temperature conditions and subsequent 

transfer to a warm room, the device heats up, causing moisture condense inside the device and damage microcircuits.

- Do not expose the device to direct sunlight and protect it from prolonged exposure to sunlight and high temperature.

- Clean the device with a soft cloth slightly made damp with a mild soap solution. Do not use cleaning solvents or abrasives. 