Maintenance
Condair TE
6.10 Checking the Electrical Connections
Open the control box and terminal block cover in the humidifier. Refer to the wiring diagram in the
installation manual for the proper wiring of the unit.
Access to the control box and terminal cover may require the removal of the drain pan and removal of
the humidification module.
Check the following:
•
Loose connections with the terminal block.
•
Loose connections with connectors and similar components.
•
Severed or deteriorated wires.
•
Discoloured or deformed relays (or similar).
6.11 Cleaning the Internal Plumbing Components
Access to the supply header nozzle, drain pump, level sensor, and float switch may require the removal
of the drain pan and humidification module.
Figure 13:
Internal components (plumbing)
To clean the plumbing components:
1. Carefully and thoroughly clean the water supply header nozzles (thin tubes) using a brush, cleaning
cloth or similar to remove scale and other contaminants.
2. Inspect the drain pump, level sensor, and float switch. Clean with a wetted, soft cloth (or similar).
Level sensor
Terminal block cover
Drain pump
Fan
Nozzle
Water supply header
Float switch
Control box (unit)