54
Maintenance and Replacement of components
6.4.2 Removal and installation of the spray nozzles
Fig. 11: Removal and installation of the spray nozzles
Removal of the spray nozzles
1. Loosen nozzle "A" by hand and remove it together with the O-ring"B".
Note: prior to the removal note the position and the colour identification of the nozzle.
2. If necessary, disassemble the nozzle according to the illustration above.
Installation of the spray nozzles
1. Before installation, check nozzle "A" and o-rings "B" and "C" for any damage.
Damaged nozzles or
damaged o-rings must be replaced.
2. If necessary, assemble the nozzle according to the illustration above.
3. Before installation of the nozzle flush the corresponding spray circuit by activating the appropriate
spray valve via the "Output Diagnostics" submenu.
4. Screw in cleaned or new nozzle with O-ring into the nozzle support and tighten it by hand until it
comes to a stop (do not use tools).
Note: make sure the nozzle is installed in the nozzle grid on the right place and with the correct
orientation.
A
C
C
B
A
Summary of Contents for DL II