Concoa Advantium 1 Plus Installation And Operating Instructions Manual Download Page 18

 

15 

WARRANTY INFORMATION 

This equipment is sold by CONTROLS CORPORATION OF AMERICA under the 
warranties set forth in the following paragraphs. Such warranties are extended only with 
respect to the purchase of this equipment directly from CONTROLS CORPORATION 
OF AMERICA or its Authorized Distributors as new merchandise and are extended to 
the first Buyer thereof other than for the purpose of resale. 

For a period of one (1) year from the date of original delivery (90 days in corrosive 
service) to Buyer or to Buyer’s order, this equipment is warranted to be free from 
functional defects in materials and workmanship and to conform to the description of this 
equipment contained in this manual and any accompanying labels and/or inserts, 
provided that the same is properly operated under conditions of normal use and that 
regular periodic maintenance and service is performed or replacements made in 
accordance with the instructions provided. The foregoing warranties shall not apply if the 
equipment has been repaired: other than by CONTROLS CORPORATION OF 
AMERICA or a designated service facility or in accordance with written instructions 
provided by CONTROLS CORPORATION OF AMERICA, or altered by anyone other 
than CONTROLS CORPORATION OF AMERICA, or if the equipment has been subject 
to abuse, misuse, negligence or accident. 

CONTROLS CORPORATION OF AMERICA’s sole and exclusive obligation and 
Buyer’s sole and exclusive remedy under the above warranties is limited to repairing or 
replacing, free of charge, at CONTROLS CORPORATION OF AMERICA’s option, the 
equipment or part, which is reported to its Authorized Distributor from whom purchased, 
and which if so advised, is returned with a statement of the observed deficiency, and 
proof of purchase of equipment or part not later than seven (7) days after the expiration 
date of the applicable warranty, to the nearest designated service facility during normal 
business hours, transportation charges prepaid, and which upon examination, is found not 
to comply with the above warranties. Return trip transportation charges for the equipment 
or part shall be paid by Buyer. 

CONTROLS CORPORATION OF AMERICA SHALL NOT BE OTHERWISE 
LIABLE FOR ANY DAMAGES INCLUDING BUT NOT LIMITED TO: 
INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, OR SPECIAL 
DAMAGES, WHETHER SUCH DAMAGES RESULT FROM NEGLIGENCE, 
BREACH OF WARRANTY OR OTHERWISE.

 

THERE ARE NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND 
BEYOND THE WARRANTIES HEREINABOVE SET FORTH. CONTROLS 
CORPORATION OF AMERICA MAKES NO WARRANTY OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH 
RESPECT TO THE EQUIPMENT OR PARTS THEREOF. 

 

Summary of Contents for Advantium 1 Plus

Page 1: ...RATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 42...

Page 2: ......

Page 3: ...EXPLOSIVE ENVIRONMENTS DO NOT INSTALL THIS PRODUCT IN ANY HAZARDOUS ENVIRONMENT If product appears damaged in any way do not use and request service from CONCOA USER RESPONSIBILITY Service to this pro...

Page 4: ...ion 2 Mounting Requirements 5 Installation Instructions 5 Connecting Alarm to Protocol Station 6 Connecting Alarm Outputs 7 Setting Remote Alarm Outputs 9 Muting Audible Alarm 11 Enabling Alarm Delay...

Page 5: ...Voltage External Power Supply Universal input voltage 90 264 VAC Power Consumption 5 watts ALARM OUTPUT RELAY SPECIFICATIONS Contacts Normally Open Normally Closed selectable Dry Contact Contact Rati...

Page 6: ...indicators for the alarm The Advantium 1 Plus has a universal power supply An ON OFF power switch is provided on the bottom of the alarm The switch must be in the ON position for the alarm to work Inp...

Page 7: ...operator to silence the audible alarm even though an alarm condition still exists This audible alarm can be disabled if desired Refer to the Section Muting Audible Alarm for instruction on how this i...

Page 8: ...the Input of the alarm If using the output of the alarm to connect to another alarm or system attach the output cable at this time Plug the alarm into the appropriate power Turn alarm ON by turning th...

Page 9: ...o connect the two devices For convenience a mating 6 pin connector is provided to use in building this cable assembly The protocol station also comes with a mating connector that is used to attach to...

Page 10: ...ur local CONCOA Distributor or call 1 800 225 0473 for information The relay contacts are configurable They are factory set as Normally Closed N C but may be changed to Normally Open N O if needed Ref...

Page 11: ...8 CONNECTING ALARM OUTPUTS cont Figure 6 Figure 7 Table 2 Remote Alarm Output Pin Assignments Alarm Output Connector Pin Number Function 1 N C 2 Inlet Alarm 3 12v provided externally 4...

Page 12: ...of the unit 3 Separate the front and back of the unit by loosening the 4 screws located on the rear of the enclosure 4 Figure 8 shows the location of the jumpers on the circuit board for setting the c...

Page 13: ...10 Figure 8...

Page 14: ...the bottom of the alarm to the ON position 9 Test unit ENABLING ALARM DELAY FUNCTION The Advantium 1 Plus has a built in alarm delay feature This feature when set will delay both the visual and audibl...

Page 15: ...OCOL STATION FACTORY DEFAULT IS NORMALLY CLOSED N C To change the input so that an input is OFF when there is no alarm and ON when an alarm occurs perform the following steps 1 Turn AC power switch OF...

Page 16: ...13 Figure 9 Table 4 SWITCH FUNCTION 1 Alarm Delay 2 Input Signal Polarity 3 Audible Alarm Mute...

Page 17: ...able assembly descriptions and part numbers Cable Description Part Number Advantium Input Cable 5295316 xx Advantium Input Extension Cable 5295317 xx Advantium Output Cable 5295320 xx Advantium Interc...

Page 18: ...other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole...

Page 19: ......

Page 20: ...ADI 9525A Certified ISO 9001 2000 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Reviews: