ACCESSORIES 

Pre-assembled cables for connecting a CONCOA Protocol Station to the Advantium 1 

Plus

 Alarm are available from your CONCOA distributor.  Refer to the table below for 

cable assembly descriptions and part numbers. 

Cable Description 

Part Number 

Advantium Input Cable  

5295316-xx* 

Advantium Input Extension Cable  

5295317-xx* 

Advantium Output Cable  

5295320-xx* 

Advantium Interconnect Cable 

5295329-xx* 

 

* - Replace ‘–xx’ with cable length.  Length is in feet.  Choices are -03 (3ft.), --10 
(10ft.), -25 (25ft.), -50 (50 ft.), -100 (100ft.)  

Example: Order 25 ft. Advantium Input Cable 

 PN 

5295316-25 

 

Summary of Contents for Advantium 1 Plus

Page 1: ...RATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 42...

Page 2: ......

Page 3: ...EXPLOSIVE ENVIRONMENTS DO NOT INSTALL THIS PRODUCT IN ANY HAZARDOUS ENVIRONMENT If product appears damaged in any way do not use and request service from CONCOA USER RESPONSIBILITY Service to this pro...

Page 4: ...ion 2 Mounting Requirements 5 Installation Instructions 5 Connecting Alarm to Protocol Station 6 Connecting Alarm Outputs 7 Setting Remote Alarm Outputs 9 Muting Audible Alarm 11 Enabling Alarm Delay...

Page 5: ...Voltage External Power Supply Universal input voltage 90 264 VAC Power Consumption 5 watts ALARM OUTPUT RELAY SPECIFICATIONS Contacts Normally Open Normally Closed selectable Dry Contact Contact Rati...

Page 6: ...indicators for the alarm The Advantium 1 Plus has a universal power supply An ON OFF power switch is provided on the bottom of the alarm The switch must be in the ON position for the alarm to work Inp...

Page 7: ...operator to silence the audible alarm even though an alarm condition still exists This audible alarm can be disabled if desired Refer to the Section Muting Audible Alarm for instruction on how this i...

Page 8: ...the Input of the alarm If using the output of the alarm to connect to another alarm or system attach the output cable at this time Plug the alarm into the appropriate power Turn alarm ON by turning th...

Page 9: ...o connect the two devices For convenience a mating 6 pin connector is provided to use in building this cable assembly The protocol station also comes with a mating connector that is used to attach to...

Page 10: ...ur local CONCOA Distributor or call 1 800 225 0473 for information The relay contacts are configurable They are factory set as Normally Closed N C but may be changed to Normally Open N O if needed Ref...

Page 11: ...8 CONNECTING ALARM OUTPUTS cont Figure 6 Figure 7 Table 2 Remote Alarm Output Pin Assignments Alarm Output Connector Pin Number Function 1 N C 2 Inlet Alarm 3 12v provided externally 4...

Page 12: ...of the unit 3 Separate the front and back of the unit by loosening the 4 screws located on the rear of the enclosure 4 Figure 8 shows the location of the jumpers on the circuit board for setting the c...

Page 13: ...10 Figure 8...

Page 14: ...the bottom of the alarm to the ON position 9 Test unit ENABLING ALARM DELAY FUNCTION The Advantium 1 Plus has a built in alarm delay feature This feature when set will delay both the visual and audibl...

Page 15: ...OCOL STATION FACTORY DEFAULT IS NORMALLY CLOSED N C To change the input so that an input is OFF when there is no alarm and ON when an alarm occurs perform the following steps 1 Turn AC power switch OF...

Page 16: ...13 Figure 9 Table 4 SWITCH FUNCTION 1 Alarm Delay 2 Input Signal Polarity 3 Audible Alarm Mute...

Page 17: ...able assembly descriptions and part numbers Cable Description Part Number Advantium Input Cable 5295316 xx Advantium Input Extension Cable 5295317 xx Advantium Output Cable 5295320 xx Advantium Interc...

Page 18: ...other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole...

Page 19: ......

Page 20: ...ADI 9525A Certified ISO 9001 2000 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Reviews: