Concoa Advantium 1 Plus Installation And Operating Instructions Manual Download Page 14

 

11 

 

MUTING AUDIBLE ALARM 

It is sometimes desirable to silence the audible alarm on the Advantium 1 

Plus

.  This can 

be accomplished by turning OFF the audible alarm switch inside the alarm.  FACTORY 
DEFAULT IS ON.  To turn OFF the audible alarm perform the following steps: 

1.

 

Turn AC power switch OFF and unplug the alarm from AC power

2.

 

If the alarm is anchored to a wall remove the four screws holding it to the wall 
to gain access to the back of the unit

.  

3.

 

Separate the front and back of the unit by loosening the 4 screws located on 
the rear of the enclosure

4.

 

Using Figure 9 locate SW2 switch 3 and turn it OFF. 

5.

 

Replace back cover using the previously removed screws. 

6.

 

Re-attach the alarm to the wall using the previously removed screws. 

7.

 

Plug the alarm back into AC power. 

8.

 

Turn alarm ON by turn the power switch on the bottom of the alarm to the ON 
position. 

9.

 

Test unit. 

 

ENABLING ALARM DELAY FUNCTION 

The Advantium 1 

Plus

 has a built in alarm delay feature.  This feature, when set, will 

delay both the visual and audible alarm signals for a period of 40 minutes. The 
Advantium 1 

Plus

 alarm is shipped from the factory with the Alarm Delay feature shut 

OFF.  If you wish to enable this alarm delay feature perform the following steps: 

1.

 

Turn AC power switch OFF and unplug the alarm from AC power

2.

 

If the alarm is anchored to a wall remove the four screws holding it to the wall 
to gain access to the back of the unit

.  

3.

 

Separate the front and back of the unit by loosening the 4 screws located on 
the rear of the enclosure

4.

 

Using Figure 9 locate SW2 switch 1 and turn it ON. 

5.

 

Replace back cover using the previously removed screws. 

6.

 

Re-attach the alarm to the wall using the previously removed screws. 

7.

 

Plug the alarm back into AC power. 

8.

 

Turn alarm ON by turn the power switch on the bottom of the alarm to the ON 
position. 

9.

 

Test unit. 

 

Summary of Contents for Advantium 1 Plus

Page 1: ...RATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 42...

Page 2: ......

Page 3: ...EXPLOSIVE ENVIRONMENTS DO NOT INSTALL THIS PRODUCT IN ANY HAZARDOUS ENVIRONMENT If product appears damaged in any way do not use and request service from CONCOA USER RESPONSIBILITY Service to this pro...

Page 4: ...ion 2 Mounting Requirements 5 Installation Instructions 5 Connecting Alarm to Protocol Station 6 Connecting Alarm Outputs 7 Setting Remote Alarm Outputs 9 Muting Audible Alarm 11 Enabling Alarm Delay...

Page 5: ...Voltage External Power Supply Universal input voltage 90 264 VAC Power Consumption 5 watts ALARM OUTPUT RELAY SPECIFICATIONS Contacts Normally Open Normally Closed selectable Dry Contact Contact Rati...

Page 6: ...indicators for the alarm The Advantium 1 Plus has a universal power supply An ON OFF power switch is provided on the bottom of the alarm The switch must be in the ON position for the alarm to work Inp...

Page 7: ...operator to silence the audible alarm even though an alarm condition still exists This audible alarm can be disabled if desired Refer to the Section Muting Audible Alarm for instruction on how this i...

Page 8: ...the Input of the alarm If using the output of the alarm to connect to another alarm or system attach the output cable at this time Plug the alarm into the appropriate power Turn alarm ON by turning th...

Page 9: ...o connect the two devices For convenience a mating 6 pin connector is provided to use in building this cable assembly The protocol station also comes with a mating connector that is used to attach to...

Page 10: ...ur local CONCOA Distributor or call 1 800 225 0473 for information The relay contacts are configurable They are factory set as Normally Closed N C but may be changed to Normally Open N O if needed Ref...

Page 11: ...8 CONNECTING ALARM OUTPUTS cont Figure 6 Figure 7 Table 2 Remote Alarm Output Pin Assignments Alarm Output Connector Pin Number Function 1 N C 2 Inlet Alarm 3 12v provided externally 4...

Page 12: ...of the unit 3 Separate the front and back of the unit by loosening the 4 screws located on the rear of the enclosure 4 Figure 8 shows the location of the jumpers on the circuit board for setting the c...

Page 13: ...10 Figure 8...

Page 14: ...the bottom of the alarm to the ON position 9 Test unit ENABLING ALARM DELAY FUNCTION The Advantium 1 Plus has a built in alarm delay feature This feature when set will delay both the visual and audibl...

Page 15: ...OCOL STATION FACTORY DEFAULT IS NORMALLY CLOSED N C To change the input so that an input is OFF when there is no alarm and ON when an alarm occurs perform the following steps 1 Turn AC power switch OF...

Page 16: ...13 Figure 9 Table 4 SWITCH FUNCTION 1 Alarm Delay 2 Input Signal Polarity 3 Audible Alarm Mute...

Page 17: ...able assembly descriptions and part numbers Cable Description Part Number Advantium Input Cable 5295316 xx Advantium Input Extension Cable 5295317 xx Advantium Output Cable 5295320 xx Advantium Interc...

Page 18: ...other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole...

Page 19: ......

Page 20: ...ADI 9525A Certified ISO 9001 2000 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Reviews: