Concoa 529 5310 Installation And Operation Instruction Manual Download Page 2

-2-

PART NUMBERS

529 5310 

Multi-Station Remote Alarm 120 VAC version

529 5311 

Multi-Station Remote Alarm 220 VAC version

DESCRIPTION OF PRODUCT

The Multi-Station Remote Alarm is set at the factory to operate at either 120VAC or 220VAC.  It is capable of 
providing operating status for up to four CONCOA Autoswitch systems.  The Multi-Station Remote Alarm provides 
power to each Autoswitch to operate the status indicator lights and the pressure switches. 

An Autoswitch product that is configured with the alarm option is equipped with two pressure switch gauges, two 
sets of status indicators, and a power status indicator.  A pressure switch gauge and one set of status indicators are 
used to monitor and report the state of the pressure for each side of the Autoswitch.

The front panel of the Remote Alarm consists of eight (8) status indicator lights, an “Alarm Silence” button, a “Test” 
button, and an audible Alarm.  See Figure 1.  In addition to the front panel, the right side of the Remote Alarm has 
a power ON-OFF switch and an IEC type connector where the AC power cable is connected.  At the bottom of the 
Alarm are three (3) connectors where the Autoswitch, Serial Port and Output Devices are connected.

The Multi-Station Remote Alarm controls five (5) sets of relay contacts that are brought to the Output Connector 
so they may be used to control an external device. 

The status indicator lights are organized into pairs representing the Left Bank and Right Bank of an Autoswitch 
System.  When all configured systems are operating normally the status indicator lights will be green.  If the pressure 
should drop below the preset value of the Autoswitch, the audible alarm will sound and the light corresponding to 
the specific Autoswitch Bank will turn from green to red.  When this 

happens, two output relays will activate; the 

MAIN relay and the AUX relay connected to the system that had the alarm condition.  The MAIN Relay will 

always activate whenever any of the AUX relays activates.  It is sometimes desirable to silence the audible alarm 

prior to the alarm condition being fixed.  Pressing the “Alarm Silence” button will accomplish this.  The status 

indicator lights and the relays will remain activated until the alarm condition is corrected.  If the second bank 

on the same Autoswitch generates an alarm while the first Bank is still in an alarm condition, the other status 

indicator light in that system will turn from green to red, however, both red status indicator lights on that system 

will start to blink ON and OFF.  If the audible alarm was previously silenced, it will sound again.

Figure 1

Audible Alarm

Status Indicator Lights

Alarm Silence Switch

Test Switch

Power Switch

Power Connector

Output Connector

Serial Port

Input Connector

Summary of Contents for 529 5310

Page 1: ...talling or Operating Read and Comply with These Instructions Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www...

Page 2: ...s that are brought to the Output Connector so they may be used to control an external device The status indicator lights are organized into pairs representing the Left Bank and Right Bank of an Autosw...

Page 3: ...mally closed switch One example of such a device would be the CONCOA telephone dialer PN 5295306 Connections to the Alarm are made through input and output connectors Customer supplied cables are easi...

Page 4: ...AUTOSWITCH To connect the Multi Station Remote Alarm to an Autoswitch system an interface cable must be made The Autoswitch systems are shipped with a connector that is used for this cable An Input C...

Page 5: ...status RIGHT BANK 5 2 alarm 4 15 RBSW status 3 3 12 6 16 Gnd 2 LEFT BANK 2 4 alarm 1 17 LBSW status RIGHT BANK 5 5 alarm 4 18 RBSW status 3 6 12 6 19 Gnd 3 LEFT BANK 2 7 alarm 1 20 LBSW status RIGHT B...

Page 6: ...rm the 4 conductor cable already exists Remove the cable from the old alarm by unscrewing the wires from the terminal block Cut the end of the cable so that the wires that went into the terminals on t...

Page 7: ...BANK 1 12 12 2 24 LBSW status RIGHT BANK 3 23 RBSW status 4 25 Gnd Table 2 CONNECTING THE OUTPUTS The Multi Station Remote Alarm activates relay contacts in response to alarm conditions These relay co...

Page 8: ...the Alarm will make this information available to the Serial Port as an 8 bit word The data is organized such that each bit represents the status of a BANK Pressure Switch Table 5 shows the bit assig...

Page 9: ...is limited to the following Command Code Keystroke Definition CAN Hex 18 Cntrl X Cancel ENQ Hex 05 Cntrl E Enquire STX Hex 02 Cntrl B Start of Text ETX Hex 03 Cntrl C End of Text DC4 Hex 14 Cntrl T D...

Page 10: ...o set the unit on a flat surface With the Alarm placed so that the Input Output connectors are facing towards you unscrew the four 4 screws that hold the cover on They are retained in the cover so the...

Page 11: ...m the Remote Alarm 2 It is best to set the unit on a flat surface With the Alarm placed so that the Input Output connectors are facing towards you unscrew the four 4 screws that hold the cover on They...

Page 12: ...ing Option 2 4 pin connector Autoswitch check that DIP switch 5 is properly set Refer to Configuring the Remote Alarm section of the manual Outputs do not appear to be functioning 1 Check the cable to...

Page 13: ...LECTRICAL SPECIFICATIONS Multi Station Remote Alarm 120 Volt Version 120 Volts 10 50 60 hz 6VA 220 Volt Version 220 Volts 10 50 60 hz 6VA Fuses 120 Volt Version 0 5A normal blow type 3AG 220 Volt Vers...

Page 14: ...14 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 15: ...one other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s s...

Page 16: ...Number Description 1 5295310 01 001 120 VAC MULTI STATION REMOTE ALARM 1 5295311 01 001 220 VAC MULTI STATION REMOTE ALARM INCLUDES 1 8308824 120 VAC MULTI STATION REMOTE ALARM 1 8308825 220 VAC MULTI...

Reviews: