66
PDV7060 / PDV7060wh
EN
Note:
1. Never hold a pressed burner knob for more than 15 seconds. If the burner does not ignite within
15 seconds, release the pressed knob and turn it to the OFF position, wait for 1 minute and then try again.
2. In case of power failure, the burners can be lit by carefully using a match.
Protection against gas leakage without flame
It is a thermoelectric cell located near the burner, which monitors the flame on the basis of heat radiation and
if the flame accidentally goes out, it closes the gas supply of the specific burner.
If a flame accidentally goes out, turn the respective knob clockwise to the OFF position. Wait one minute and
reignite the burner.
REPLACEMENT OF NOZZLES AND ADJUSTMENT OF THE MINIMUM
FLAME HEIGHT
Replacement of burner nozzles and adjustment of the minimum flame height may be performed only by
a qualified professional or authorized service personnel.
Replacement of burner nozzles
1. Close the gas supply and pull out the plug from the electrical socket.
2. Remove the burner grate, burner cover and flame spreader.
3. Unscrew the nozzle using a 7mm socket spanner and replace it with a nozzle for a different gas type.
Firmly tighten the nozzle.
4. Reassemble all parts of the burner (flame spreader, cover and grate).
Nozzle
Summary of Contents for PDV7060