Operation
TrueBlend
™
72
Edition: February 2007
7.10 TrueBlend Setup
Operating mode, batch weight, mixing time and interval time can be set in True-
Blend Setup.
Î
Press the TrueBlend body icon (green
column) in the center of the "TrueBlend
Status" screen.
Î
The TrueBlend setup will come up.
7.10.1 Setting Operating mode
The operating mode specifies whether the unit will operate gravimetrically, volu-
metrically or in mixed operating mode (see 5.3.1 Operating modes).
Î
Press the dropdown menu and select
the operating mode.
•
grav.:
all components are metered and
weighed in sequence (gravimetrically).
•
volu.:
all components are metered in
sequence without weighing (volumetri-
cally).
•
mix. 1-8:
a gravimetric cycle is followed
by a number (1-8) of volumetric cycles.
The number shows how many volumet-
ric cycles will follow a gravimetric cycle.